Evaluation of a fiber probe coupled with half ball lens for depth-resolved fluorescence measurements

被引:0
|
作者
Jaillon, Franck [1 ]
Zheng, Wei [1 ]
Huang, Zhiwei [1 ]
机构
[1] Natl Univ Singapore, Fac Engn, Bioimaging Lab, Dept Bioengn, Singapore 117576, Singapore
关键词
half ball lens; beveled fiber; epithelial tissue; fluorescence spectroscopy; Monte Carlo simulations;
D O I
10.1117/12.762177
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The association of a beveled collection fiber with a half ball lens is here simulated in order to illustrate the enhancement brought by this simple method in depth resolved measurements, the latter being of major importance in the study of epithelial tissues. Indeed, in order to follow the carcinogenesis stage by a non invasive technique such as fluorescence or Raman spectroscopy, it is valuable to be able to discriminate the depth origin of the detected signal. The proposed probe design consists in a beveled collection fiber positioned on the center of the half ball lens flat surface with an off-axis excitation flat fiber. Depending on the bevel angle of the collection fiber, discrimination between the epithelial and the stromal layer can be realized.
引用
收藏
页码:U79 / U83
页数:5
相关论文
共 50 条
  • [21] Depth-resolved transport measurements and atom-probe tomography of heterogeneous, superconducting Ge:Ga films
    Heera, V.
    Fiedler, J.
    Naumann, M.
    Skrotzki, R.
    Koelling, S.
    Wilde, L.
    Herrmannsdoerfer, T.
    Skorupa, W.
    Wosnitza, J.
    Helm, M.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2014, 27 (05):
  • [22] An ultraslim all-fiber microendoscope for depth-resolved imaging
    Pochechuev, M. S.
    Fedotov, I. V.
    Zheltikov, A. M.
    APPLIED PHYSICS LETTERS, 2018, 113 (19)
  • [23] Depth-resolved water temperature measurements using Raman LiDAR
    Spence, D. J.
    Kitzler, O.
    Taylor, C. J.
    Curtis, S. A.
    Neimann, B. R.
    Dawes, J. M.
    Downes, J. E.
    Pask, H. M.
    APPLIED OPTICS, 2024, 63 (16) : 4366 - 4371
  • [24] Depth-resolved temperature measurements of water using the Brillouin lidar technique
    K. Schorstein
    E. S. Fry
    T. Walther
    Applied Physics B, 2009, 97 : 931 - 934
  • [25] Real-time Depth-resolved Shack-Hartmann Measurements
    Wang, Jingyu
    Podoleanu, Adrian Gh
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE TECHNIQUES VI, 2013, 8802
  • [26] Depth-resolved temperature measurements on power devices under transient conditions
    Perpina, X.
    Jorda, X.
    Vellvehia, M.
    Mermet-Guyennet, M.
    Millan, J.
    Mestres, N.
    PROCEEDINGS OF THE 19TH INTERNATIONAL SYMPOSIUM ON POWER SEMICONDUCTOR DEVICES AND ICS, 2007, : 33 - +
  • [27] Depth-resolved temperature measurements of water using the Brillouin lidar technique
    Schorstein, K.
    Fry, E. S.
    Walther, T.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2009, 97 (04): : 931 - 934
  • [28] Depth-resolved fluorescence imaging of neoplastic and non-neoplastic epithelial tissues
    Skala, M
    Squirrell, J
    Vrotsos, K
    Eliceiri, K
    Ramanujam, N
    LASERS IN SURGERY AND MEDICINE, 2004, : 51 - 51
  • [29] Depth-resolved fluorescence lifetime spectroscopy across the cornea in the digital frequency domain
    Srinivas, Sangly P.
    Sun, Yuansheng
    Povrozin, Yevgen
    Redes, Norin
    Ranganath, Sudhir H.
    Damale, Sahana
    Sushma, T.
    Barbieri, Beniamino
    MULTIPHOTON MICROSCOPY IN THE BIOMEDICAL SCIENCES XXII, 2022, 11965
  • [30] DEPTH-RESOLVED MICROVISCOSITY OF THE AIRWAY SURFACE LIQUID MEASURED BY CONFOCAL FLUORESCENCE PHOTOBLEACHING
    Derichs, N.
    Thiagarajah, J. R.
    Song, Y.
    Finkbeiner, W. E.
    Verkman, A. S.
    PEDIATRIC PULMONOLOGY, 2010, : 252 - 252