Evaluation of a fiber probe coupled with half ball lens for depth-resolved fluorescence measurements

被引:0
|
作者
Jaillon, Franck [1 ]
Zheng, Wei [1 ]
Huang, Zhiwei [1 ]
机构
[1] Natl Univ Singapore, Fac Engn, Bioimaging Lab, Dept Bioengn, Singapore 117576, Singapore
关键词
half ball lens; beveled fiber; epithelial tissue; fluorescence spectroscopy; Monte Carlo simulations;
D O I
10.1117/12.762177
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The association of a beveled collection fiber with a half ball lens is here simulated in order to illustrate the enhancement brought by this simple method in depth resolved measurements, the latter being of major importance in the study of epithelial tissues. Indeed, in order to follow the carcinogenesis stage by a non invasive technique such as fluorescence or Raman spectroscopy, it is valuable to be able to discriminate the depth origin of the detected signal. The proposed probe design consists in a beveled collection fiber positioned on the center of the half ball lens flat surface with an off-axis excitation flat fiber. Depending on the bevel angle of the collection fiber, discrimination between the epithelial and the stromal layer can be realized.
引用
收藏
页码:U79 / U83
页数:5
相关论文
共 50 条
  • [1] Ball lens coupled fiber-optic probe for depth-resolved spectroscopy of epithelial tissue
    Schwarz, RA
    Arifler, D
    Chang, SK
    Pavlova, I
    Hussain, IA
    Mack, V
    Knight, B
    Richards-Kortum, R
    Gillenwater, AM
    OPTICS LETTERS, 2005, 30 (10) : 1159 - 1161
  • [2] Microlensed dual-fiber probe for depth-resolved fluorescence measurements
    Choi, Hae Young
    Ryu, Seon Young
    Kim, Jae Young
    Kim, Geon Hee
    Park, Seong Jun
    Lee, Byeong Ha
    Chang, Ki Soo
    OPTICS EXPRESS, 2011, 19 (15): : 14172 - 14181
  • [3] Half-ball lens couples a beveled fiber probe for depth-resolved spectroscopy: Monte Carlo simulations
    Jaillon, Franck
    Zheng, Wei
    Huang, Zhiwei
    APPLIED OPTICS, 2008, 47 (17) : 3152 - 3157
  • [4] Beveled fiber-optic probe couples a ball lens for improving depth-resolved fluorescence measurements of layered tissue: Monte Carlo simulations
    Jaillon, Franck
    Zheng, Wei
    Huang, Zhiwei
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (04): : 937 - 951
  • [5] Fiber probe configurations simulation for depth-resolved skin fluorescence registration
    Artemyev, Dmitry N.
    Shatskaya, Anastasiya A.
    Bratchenko, Ivan A.
    TISSUE OPTICS AND PHOTONICS, 2020, 11363
  • [6] Novel fiber-optic probe design for depth-resolved fluorescence measurements: Monte Carlo simulations
    Jaillon, Franck
    Zheng, Wei
    Huang, Zhiwei
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS III, 2008, 6826
  • [7] Effect of fiber optic probe geometry on depth-resolved fluorescence measurements from epithelial tissues: a Monte Carlo simulation
    Zhu, CF
    Liu, Q
    Ramanujam, N
    JOURNAL OF BIOMEDICAL OPTICS, 2003, 8 (02) : 237 - 247
  • [8] Depth-resolved fluorescence of biological tissue
    Wu, YC
    Xi, P
    Cheung, TH
    Yim, SF
    Yu, MY
    Qu, JNY
    Saratov Fall Meeting 2004: Optical Technologies in Biophysics and Medicine VI, 2005, 5771 : 252 - 255
  • [9] Depth-resolved fluorescence of human ectocervical tissue
    Wu, YC
    Xi, P
    Cheung, TH
    Yim, SF
    Yu, MY
    Qu, JY
    Advanced Biomedical and Clinical Diagnostic Systems III, 2005, 5692 : 127 - 132
  • [10] Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology
    Zhu, Yizheng
    Terry, Neil G.
    Woosley, John T.
    Shaheen, Nicholas J.
    Wax, Adam
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (01)