The cooling and heating potential of an earth tube system in buildings

被引:120
|
作者
Lee, Kwang Ho [1 ]
Strand, Richard K. [1 ]
机构
[1] Univ Illinois, Champaign, IL 61820 USA
关键词
earth tube; EnergyPlus; parametric analysis; cooling and heating potential;
D O I
10.1016/j.enbuild.2007.04.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A new module was developed for and implemented in the EnergyPlus program for the simulation of earth tubes. The model was validated against and showed good agreement with both theoretical and experimental data. Using the new module, a parametric analysis was carried out to investigate the effect of pipe radius, pipe length, air flow rate and pipe depth on the overall performance of the earth tube under various conditions during cooling season. Pipe length and pipe depth turned out to affect the overall cooling rate of the earth tube, while pipe radius and air flow rate mainly affect earth tube inlet temperature. The cooling and heating potential of earth tubes in four different locations were also investigated, Whether or not an earth tube is beneficial turned out to be heavily dependent on the climate of the location. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
  • [31] LOW EXERGY HEATING AND COOLING IN RESIDENTIAL BUILDINGS
    Jochum, Michael
    Murugesan, Gokulakrishnan
    Kissock, Kelly
    Hallinan, Kevin
    PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, 2012, : 2007 - 2013
  • [32] Cooling and heating loads in residential buildings in Jordan
    Shariah, A
    Tashtoush, B
    Rousan, A
    ENERGY AND BUILDINGS, 1997, 26 (02) : 137 - 143
  • [33] Using Fouggara for Heating and Cooling Buildings in Sahara
    Amara, S.
    Nordell, B.
    Benyoucef, B.
    IMPACT OF INTEGRATED CLEAN ENERGY ON THE FUTURE OF THE MEDITERRANEAN ENVIRONMENT, 2011, 6 : 55 - 64
  • [34] Reducing the heating and cooling energy consumption of buildings
    College of Urban Construction and Environmental Engineering, Chongqing University, Chongqing 400030, China
    不详
    不详
    Chongqing Jianzhu Daxue Xuebao, 2008, 4 (6-9+26):
  • [35] SOLAR HEATING AND COOLING OF BUILDINGS - HARRELL,JJ
    不详
    SOLAR ENERGY, 1983, 31 (05) : 527 - 527
  • [36] HEATING AND COOLING POTENTIAL OF AN UNDERGROUND AIR-PIPE SYSTEM
    SAWHNEY, RL
    MAHAJAN, U
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1994, 18 (05) : 509 - 524
  • [37] PERFORMANCE EVALUATION OF BUILDINGS ASSOCIATED WITH EARTH TO AIR HEAT-EXCHANGERS - THE COOLING POTENTIAL
    SANTAMOURIS, M
    AGAS, G
    MATSAGOS, T
    ARGYRIOU, T
    THEOFILAKTOS, K
    ARCHITECTURE AND URBAN SPACE, 1991, : 637 - 642
  • [38] The cooling potential of earth-air heat exchangers for domestic buildings in a desert climate
    Al-Ajmi, F
    Loveday, DL
    Hanby, VI
    BUILDING AND ENVIRONMENT, 2006, 41 (03) : 235 - 244
  • [39] Evolving from an indirect evaporative cooling system to a radiant-capacitive heating and cooling system for low-mass buildings
    Kruger, E. L.
    Cruz, E. M. Gonzalez
    JOURNAL OF BUILDING ENGINEERING, 2023, 79
  • [40] Shallow geothermal energy potential for heating and cooling of buildings with regeneration under climate change scenarios
    Walch, Alina
    Li, Xiang
    Chambers, Jonathan
    Mohajeri, Nahid
    Yilmaz, Selin
    Patel, Martin
    Scartezzini, Jean-Louis
    ENERGY, 2022, 244