AUTOMATIC PROCEDURE FOR SPECTROPHOTOMETRIC DETERMINATION OF HYDROQUINONE EMPLOYING MULTICOMMUTATION FLOW IN ANALYSIS SYSTEM.

被引:0
|
作者
de Aquino Lima, Manoel de Jesus [1 ,2 ]
Castilho, Quesia Guedes da Silva [1 ]
Fernandes, Ridvan Nunes [1 ]
Tanaka, Auro Atsushi [1 ]
dos Reis, Boaventura Freire [2 ]
机构
[1] Univ Fed Maranhao, Dept Quim, BR-65080805 Sao Luis, MA, Brazil
[2] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Piracicaba, SP, Brazil
来源
QUIMICA NOVA | 2016年 / 39卷 / 05期
关键词
hydroquinone; multicommuted flow system; spectrophotometric analysis; INJECTION-ANALYSIS; HYDROGEN-PEROXIDE; KOJIC ACID; CHEMISTRY; CATECHOL; PHENOL;
D O I
10.5935/01.00-4042.20160070
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This paper describes a procedure based on multicommutation in flow analysis system for photometric determination of hydroquinone in pharmaceutical gel formulations. The procedure involves oxidation of hydroquinone by Fe (III) and subsequent reaction between the generated Fe (II) species with 1,10-phenanthroline, producing a complex detected at 510 nm. Under optimized conditions, the proposed system showed a linear response in the range between 5 to 120 mu mol L-1 (r = 0.9995), a limit of detection (36) 0.52 mu mol L-1 and a relative standard deviation (RSD) of 1.5% for a 80 innol L-1 hydroquinone standard solution. Others profitable features such as an analytical frequency of 72 samples per hour; a reagent consumption of 0.432 and 0.117 mg 1-10-phenantroline and FeCl3 center dot 6H(2)O per determination, respectively; and a waste generation of 4.0 ml per determination were also achieved.
引用
收藏
页码:592 / 597
页数:6
相关论文
共 50 条
  • [31] SPECTROPHOTOMETRIC DETERMINATION OF ERGOT ALKALOIDS - A MODIFIED PROCEDURE EMPLOYING PARADIMETHYLAMINOBENZALDEHYDE
    MICHELON, LE
    KELLEHER, WJ
    LLOYDIA, 1963, 26 (03): : 192 - &
  • [32] Automatic microdistillation flow-injection system for the spectrophotometric determination of fluoride
    Shimada, K
    Shimoda, T
    Kokusen, H
    Nakano, S
    TALANTA, 2005, 66 (01) : 80 - 85
  • [33] MULTICOMMUTATION IN FLOW-ANALYSIS .1. BINARY SAMPLING - CONCEPTS, INSTRUMENTATION AND SPECTROPHOTOMETRIC DETERMINATION OF IRON IN PLANT DIGESTS
    REIS, BF
    GINE, MF
    ZAGATTO, EAG
    LIMA, JLFC
    LAPA, RA
    ANALYTICA CHIMICA ACTA, 1994, 293 (1-2) : 129 - 138
  • [34] Determination of glucose in soft drink and sugar-cane juice employing a multicommutation approach in flow system and enzymatic reaction
    Eloísa A. M. Kronka
    Ana Paula S. Paim
    B. F. Reis
    José L. F. Costa Lima
    Rui A. Lapa
    Fresenius' Journal of Analytical Chemistry, 1999, 364 : 358 - 361
  • [35] MULTICOMMUTATION IN FLOW-ANALYSIS .2. BINARY SAMPLING FOR SPECTROPHOTOMETRIC DETERMINATION OF NICKEL, IRON AND CHROMIUM IN STEEL ALLOYS
    MARTELLI, PB
    REIS, BF
    KRONKA, EAM
    BERGAMIN, H
    KORN, M
    ZAGATTO, EAG
    LIMA, JLFC
    ARAUJO, AN
    ANALYTICA CHIMICA ACTA, 1995, 308 (1-3) : 397 - 405
  • [36] Didactic experiments employing a flow injection system.
    Rocha, FRP
    Martelli, PB
    dos Reis, BF
    QUIMICA NOVA, 2000, 23 (01): : 119 - 125
  • [37] COAL FLOW - AN AUTOMATIC REGISTERING SYSTEM.
    Anon
    1600, (233):
  • [38] AUTOMATIC MULTISYRINGE FLOW INJECTION SYSTEM FOR THE SPECTROPHOTOMETRIC DETERMINATION OF TINIDAZOLE IN PHARMACEUTICAL PREPARATIONS
    Guzman-Mar, J. L.
    Hinojoza-Reyes, L.
    Hernandez-Ramirez, A.
    Peralta-Hernandez, J. M.
    Lopez-Chuken, V. J.
    Lopez-De-Alba, P. L.
    Cerda-Martin, V.
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2010, 55 (02): : 215 - 218
  • [39] Spectrophotometric determination of iron and aluminium in plant digests employing binary sampling in flow analysis
    Kronka, EAM
    Reis, BF
    QUIMICA ANALITICA, 1998, 17 (01): : 15 - 20
  • [40] Determination of phenols in waters using micro-pumped multicommutation and spectrophotometric detection: an automated alternative to the standard procedure
    Eva Ródenas-Torralba
    Ángel Morales-Rubio
    Miguel de la Guardia
    Analytical and Bioanalytical Chemistry, 2005, 383 : 138 - 144