Changes in retinal nerve fiber layer thickness measurements in response to a trifocal intraocular lens implantation

被引:6
|
作者
Garcia-Bella, Javier [1 ,2 ,3 ]
Talavero-Gonzalez, Paula [4 ]
Carballo-Alvarez, Jesus [5 ]
Sanz-Fernandez, Juan C. [5 ]
Vazquez-Molini, Jose M. [5 ]
Garcia-Feijoo, Julian [1 ,2 ,3 ]
Martinez-de-la-Casa, Jose M. [1 ,2 ,3 ]
机构
[1] Hosp Clin San Carlos, Serv Oftalmol, Madrid, Spain
[2] Univ Complutense Madrid, Fac Med, Dept Oftalmol, Madrid, Spain
[3] Hosp Clin San Carlos IdISSC, Inst Invest Sanitaria, Madrid, Spain
[4] Fdn Jimenez Diaz, Serv Oftalmol, Madrid, Spain
[5] Univ Complutense Madrid, Fac Opt, Madrid, Spain
关键词
OPTICAL COHERENCE TOMOGRAPHY; PHACOEMULSIFICATION CATARACT-SURGERY; DOMAIN; REPEATABILITY; REPRODUCIBILITY;
D O I
10.1038/s41433-018-0141-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To determine the changes produced on the peripapillary retinal nerve fiber layer (RNFL) thickness, measured by an spectral-domain optical coherence tomography (OCT), after the implantation of a trifocal diffractive intraocular lens (IOL) and compare them with the variations produced by a monofocal IOL implantation. Methods A prospective, double masked study in which 50 eyes belonging to 50 patients with bilateral cataract were enrolled. Sequentially, the first 25 patients were bilaterally implanted with the trifocal diffractive IOL AT LISA (R) Tri 839 MP and the following 25 patients with the monofocal IOL CT ASPHINA (R) 409 M/MP. RNFL thickness measurements were performed by Cirrus HD (R)-OCT before and six months after the second eye surgery. Results Mean patient age was 69.5 +/- 6.1 years. In response to surgery, the average RNFL thickness increased 7.29 +/- 10.51 mu m at the AT LISA (R) Tri group and 1.96 +/- 2.90 mu m at the monofocal IOL group from the baseline (p = 0.017). Statistically significant differences in thickness variations were also detected in the superior sector (7.86 +/- 7.70 mu m at the AT LISA (R) Tri group vs 1.73 +/- 5.74 mu m at the monofocal group). Statistically significant differences between the pre and the postsurgery measurements were found in all sectors except the inferior one with the trifocal IOL and in two of the studied sectors (average and temporal) with the monofocal IOL. Conclusions The IOL implantation produce changes in the RNFL thickness, which are larger in case of a trifocal diffractive IOL.
引用
收藏
页码:1574 / 1578
页数:5
相关论文
共 50 条
  • [41] Author Response: Retinal Nerve Fiber Layer Thickness Measurements in Rats with the Spectral Domain Optical Coherence Tomography
    Lange, Katharina
    Baehr, Mathias
    Hein, Katharina
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (07) : 3570 - 3571
  • [42] Retinal Nerve Fiber Layer Progression in Glaucoma A Comparison between Retinal Nerve Fiber Layer Thickness and Retardance
    Xu, Guihua
    Weinreb, Robert N.
    Leung, Christopher K. S.
    OPHTHALMOLOGY, 2013, 120 (12) : 2493 - 2500
  • [43] Retinal Nerve Fiber Layer Changes after Intraocular Silicone Oil Tamponade in Rhegmatogenous Retinal Detachment
    Chikmah, Fitri Annur
    Ichsan, Andi Muhammad
    Islam, Itzar Chaidir
    Hendarto, Joko
    Muhiddin, Habibah Setyawati
    Budu
    VISION, 2023, 7 (01)
  • [44] Clinical Outcomes of Diffractive Aspheric Trifocal Intraocular Lens Implantation
    Lee, Jung Hyun
    Cho, Young Joo
    Lim, Tae Hyung
    Choi, Kee Yong
    Cho, Beom Jin
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2018, 59 (02): : 145 - 152
  • [45] Visual performance after the implantation of a new trifocal intraocular lens
    Vryghem, Jerome C.
    Heireman, Steven
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 1957 - 1965
  • [46] Clinical Outcomes After Implantation of a Trifocal Toric Intraocular Lens
    Kretz, Florian T. A.
    Breyer, Detlev
    Klabe, Karsten
    Hagen, Phillipp
    Kaymak, Hakan
    Koss, Michael J.
    Gerl, Matthias
    Mueller, Matthias
    Gerl, Ralf H.
    Auffarth, Gerd U.
    JOURNAL OF REFRACTIVE SURGERY, 2015, 31 (08) : 504 - 510
  • [47] Reproducibility of nerve fiber layer thickness measurements
    Weinreb, RN
    Zangwill, L
    OPHTHALMOLOGY, 1997, 104 (10) : 1530 - 1531
  • [48] Comparability of retinal nerve fiber layer thickness measurements of optical coherence tomography instruments
    Bourne, RRA
    Medeiros, FA
    Bowd, C
    Jahanbakhsh, K
    Zangwill, LM
    Weinreb, RN
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (04) : 1280 - 1285
  • [49] Scanning laser polarimetry retinal nerve fiber layer thickness measurements after LASIK
    Zangwill, LM
    Abunto, T
    Bowd, C
    Angeles, R
    Schanzlin, DJ
    Weinreb, RN
    OPHTHALMOLOGY, 2005, 112 (02) : 200 - 207
  • [50] Evaluation of Retinal Nerve Fiber Layer Thickness Measurements in Longitudinally Extensive Transverse Myelitis
    Fernandes, D. B.
    Moura, F. C.
    Pereira, S. A.
    CaHadar, D.
    Marchiori, P. E.
    Monteiro, M. L. R.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)