Changes in retinal nerve fiber layer thickness measurements in response to a trifocal intraocular lens implantation

被引:6
|
作者
Garcia-Bella, Javier [1 ,2 ,3 ]
Talavero-Gonzalez, Paula [4 ]
Carballo-Alvarez, Jesus [5 ]
Sanz-Fernandez, Juan C. [5 ]
Vazquez-Molini, Jose M. [5 ]
Garcia-Feijoo, Julian [1 ,2 ,3 ]
Martinez-de-la-Casa, Jose M. [1 ,2 ,3 ]
机构
[1] Hosp Clin San Carlos, Serv Oftalmol, Madrid, Spain
[2] Univ Complutense Madrid, Fac Med, Dept Oftalmol, Madrid, Spain
[3] Hosp Clin San Carlos IdISSC, Inst Invest Sanitaria, Madrid, Spain
[4] Fdn Jimenez Diaz, Serv Oftalmol, Madrid, Spain
[5] Univ Complutense Madrid, Fac Opt, Madrid, Spain
关键词
OPTICAL COHERENCE TOMOGRAPHY; PHACOEMULSIFICATION CATARACT-SURGERY; DOMAIN; REPEATABILITY; REPRODUCIBILITY;
D O I
10.1038/s41433-018-0141-0
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To determine the changes produced on the peripapillary retinal nerve fiber layer (RNFL) thickness, measured by an spectral-domain optical coherence tomography (OCT), after the implantation of a trifocal diffractive intraocular lens (IOL) and compare them with the variations produced by a monofocal IOL implantation. Methods A prospective, double masked study in which 50 eyes belonging to 50 patients with bilateral cataract were enrolled. Sequentially, the first 25 patients were bilaterally implanted with the trifocal diffractive IOL AT LISA (R) Tri 839 MP and the following 25 patients with the monofocal IOL CT ASPHINA (R) 409 M/MP. RNFL thickness measurements were performed by Cirrus HD (R)-OCT before and six months after the second eye surgery. Results Mean patient age was 69.5 +/- 6.1 years. In response to surgery, the average RNFL thickness increased 7.29 +/- 10.51 mu m at the AT LISA (R) Tri group and 1.96 +/- 2.90 mu m at the monofocal IOL group from the baseline (p = 0.017). Statistically significant differences in thickness variations were also detected in the superior sector (7.86 +/- 7.70 mu m at the AT LISA (R) Tri group vs 1.73 +/- 5.74 mu m at the monofocal group). Statistically significant differences between the pre and the postsurgery measurements were found in all sectors except the inferior one with the trifocal IOL and in two of the studied sectors (average and temporal) with the monofocal IOL. Conclusions The IOL implantation produce changes in the RNFL thickness, which are larger in case of a trifocal diffractive IOL.
引用
收藏
页码:1574 / 1578
页数:5
相关论文
共 50 条
  • [1] Changes in retinal nerve fiber layer thickness measurements in response to a trifocal intraocular lens implantation
    Javier García-Bella
    Paula Talavero-González
    Jesús Carballo-Álvarez
    Juan C. Sanz-Fernández
    José M. Vázquez-Moliní
    Julián García-Feijóo
    José M. Martínez-de-la-Casa
    Eye, 2018, 32 : 1574 - 1578
  • [2] Retinal Nerve Fiber Layer Thickness Changes after Phacoemulsification with Intraocular Lens Implantation
    Amjad, Arooj
    Shaheer, Muhammad
    Rafique, Asima
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2018, 28 (12): : 919 - 922
  • [3] Variations in retinal nerve fiber layer measurements on optical coherence tomography after implantation of trifocal intraocular lens
    Garcia-Bella, Javier
    Martinez de la Casa, Jose M.
    Talavero Gonzalez, Paula
    Fernandez-Vigo, Jose I.
    Valcarce Rial, Laura
    Garcia-Feijoo, Julian
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (01) : 32 - 35
  • [4] Retinal nerve fiber layer thickness changes after an acute increase in intraocular pressure
    Lester, M
    Tizte, P
    Mermoud, A
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12): : 2117 - 2122
  • [5] Changes in intraocular pressure, and corneal and retinal nerve fiber layer thickness during hemodialysis
    Dinc U.A.
    Ozdek S.
    Aktas Z.
    Guz G.
    Onol M.
    International Ophthalmology, 2010, 30 (4) : 337 - 340
  • [6] Human lens effect on in vivo scanning laser polarimetric measurements of retinal nerve fiber layer thickness
    Collur, S
    Carroll, AM
    Cameron, BD
    OPHTHALMIC SURGERY AND LASERS, 2000, 31 (02): : 126 - 130
  • [7] Effect of cataract extraction with intraocular lens (IOL) implantation on scanning laser polarimetry (NFA/GDx) measurement of retinal nerve fiber layer (RNFL) thickness
    Blom, DPC
    Cameron, BD
    Eisenberg, ER
    Clements, P
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S958 - S958
  • [8] The Effect of Acute Intraocular Pressure Elevation on Peripapillary Retinal Thickness, Retinal Nerve Fiber Layer Thickness, and Retardance
    Fortune, Brad
    Yang, Hongli
    Strouthidis, Nicholas G.
    Cull, Grant A.
    Grimm, Jonathan L.
    Downs, J. Crawford
    Burgoyne, Claude F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (10) : 4719 - 4726
  • [9] Retinal nerve fiber layer and retinal thickness changes in multiple system atrophy
    Lee, J. Y.
    Ahn, J.
    Kim, T. W.
    MOVEMENT DISORDERS, 2015, 30 : S319 - S320
  • [10] CORNEAL THICKNESS MEASUREMENTS FOLLOWING INTRAOCULAR LENS IMPLANTATION
    PRAEGER, DL
    SCHNEIDER, HA
    OPHTHALMIC SURGERY AND LASERS, 1977, 8 (03): : 97 - 101