Evaluation of device-associated infections in a neonatal intensive care unit

被引:0
|
作者
Yalaz, Mehmet [1 ]
Altun-Koroglu, Ozge [1 ]
Ulusoy, Behiye [3 ]
Yildiz, Basak [2 ]
Akisu, Mete [1 ]
Vardar, Fadil [2 ,3 ]
Ozinel, Mehmet Ali [4 ]
Kultursay, Nilgun [1 ]
机构
[1] Ege Univ, Fac Med, Div Neonatol, Dept Pediat, Izmir, Turkey
[2] Ege Univ, Fac Med, Div Pediat Infect Dis, Dept Pediat, Izmir, Turkey
[3] Ege Univ, Fac Med, Hosp Infect Control Comm, Izmir, Turkey
[4] Ege Univ, Dept Clin Microbiol, Fac Med, Izmir, Turkey
关键词
nosocomial; newborn; device-associated infection; ventilator-associated pneumonia; catheter-associated infection; VENTILATOR-ASSOCIATED PNEUMONIA; BLOOD-STREAM INFECTIONS; NOSOCOMIAL INFECTIONS; RISK-FACTORS; PROSPECTIVE SURVEILLANCE; TURKEY; NICU;
D O I
暂无
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Yalaz M, Altun-Koroglu O, Ulusoy B, Yildiz B, Akisu M, Vardar F, Ozinel MA, Kultursay N. Evaluation of device-associated infections in a neonatal intensive care unit. Turk J Pediatr 2012; 54: 128-135. Device-associated infections are common in Neonatal Intensive Care Units (NICUs) in accordance with the frequent use of invasive devices, and they must be continuously and closely monitored for infection control. Six hundred newborn infants hospitalized longer than 72 hours in Ege University Children's Hospital NICU between January 2008 and December 2010 were prospectively followed for occurrence of device-associated infections (central venous catheter- and umbilical catheter-associated blood stream infections [CVC/UC BSI] and ventilator-associated pneumonia [VAP]). In a total of 10,052 patient days, the VAP rate was 13.76/1000 ventilator days with a ventilator utilization ratio of 0.29, and the CVC/UC BSI rate was 3.8/1000 catheter days with a catheter utilization ratio of 0.24. The CVC/UC BSI rate was lower than national averages, being close to rates reported from developed countries. The VAP rate was higher than the national and international rates and was associated with prolonged mechanical ventilation and very low birth weight. VAP also appeared to be an important risk factor for mortality. The most frequent agents were gram-negative pathogens for YAP and coagulase-negative staphylococci for CVC/UC BSIs, with resistance patterns similar to the previous years. In conclusion, with device utilization rates similar to those in developed countries, our CVC/UC BSI rate was comparable, but the YAP rate was higher than that of the developed countries. Necessary precautions are urgently needed to decrease YAP rates and YAP-related mortality.
引用
收藏
页码:128 / 135
页数:8
相关论文
共 50 条
  • [31] Incidence and risk factors of device-associated infections and associated mortality at the intensive care in the Dutch surveillance system
    Tjallie I. I. van der Kooi
    Annette S. de Boer
    Judith Manniën
    Jan C. Wille
    Mariëlle T. Beaumont
    Ben W. Mooi
    Susan van den Hof
    Intensive Care Medicine, 2007, 33
  • [32] International nosocomial infection control consortium findings of device-associated infections rate in an intensive care unit of a Lebanese university hospital
    Kanj, S. S.
    Kanafani, Z. A.
    Sidani, N.
    Alamuddin, L.
    Zahreddine, N.
    Rosenthal, V. D.
    JOURNAL OF GLOBAL INFECTIOUS DISEASES, 2012, 4 (01) : 15 - 21
  • [33] Epidemiology of device-associated infections in an intensive care unit of a teaching hospital in Nepal: A prospective surveillance study from a developing country
    Parajuli, Narayan Prasad
    Acharya, Subhash Prasad
    Dahal, Santosh
    Singh, Jaya Prasad
    Mishra, Shyam Kumar
    Kattel, Hari Prasad
    Rijal, Basista Prasad
    Pokhrel, Bharat Mani
    AMERICAN JOURNAL OF INFECTION CONTROL, 2017, 45 (09) : 1024 - 1029
  • [34] The Effectiveness of Device-Associated Healthcare Infections Prevention Measures in the Incidence of Infections and Mortality in Prevalent Kidney Transplant Recipients Admitted to an Intensive Care Unit
    Mota, L.
    Peruzzo, M.
    Foresto, R. D.
    Tedesco-Silva, H.
    Medina-Pestana, J.
    Requiao-Moura, L.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2023, 23 (06) : S792 - S792
  • [35] Incidence and risk factors of device-associated infections and associated mortality at the intensive care in the Dutch surveillance system
    van der Kooi, Tjallie I. I.
    de Boer, Annette S.
    Mannien, Judith
    Wille, Jan C.
    Beaumont, Marielle T.
    Mooi, Ben W.
    van den Hof, Susan
    INTENSIVE CARE MEDICINE, 2007, 33 (02) : 271 - 278
  • [36] Device-associated nosocomial infection surveillance in neonatal intensive care using specified criteria for neonates
    Gastmeier, P.
    Hentschel, J.
    de Veer, I
    Obladen, M.
    Rueden, H.
    JOURNAL OF HOSPITAL INFECTION, 1998, 38 (01) : 51 - 60
  • [37] Healthcare-associated infections in a neonatal intensive care unit in Turkey
    Bolat, Fatih
    Uslu, Sinan
    Bolat, Guher
    Comert, Serdar
    Can, Emrah
    Bulbul, Ali
    Nuhoglu, Asiye
    INDIAN PEDIATRICS, 2012, 49 (12) : 951 - 957
  • [38] Healthcare-associated infections in a neonatal intensive care unit in Turkey
    Fatih Bolat
    Sinan Uslu
    Guher Bolat
    Serdar Comert
    Emrah Can
    Ali Bulbul
    Asiye Nuhoglu
    Indian Pediatrics, 2012, 49 : 951 - 957
  • [39] Device-associated infections in the intensive care units of Cyprus: results of the first national incidence study
    Gikas, A.
    Roumbelaki, M.
    Bagatzouni-Pieridou, D.
    Alexandrou, M.
    Zinieri, V.
    Dimitriadis, I.
    Kritsotakis, E. I.
    INFECTION, 2010, 38 (03) : 165 - 171
  • [40] Device-associated infections in the intensive care units of Cyprus: results of the first national incidence study
    A. Gikas
    M. Roumbelaki
    D. Bagatzouni-Pieridou
    M. Alexandrou
    V. Zinieri
    I. Dimitriadis
    E. I. Kritsotakis
    Infection, 2010, 38 : 165 - 171