Boiler Tube Leakage Acoustic Localization Base on AGA

被引:1
|
作者
Wang, Peng [1 ]
An, Liansuo [1 ]
Shen, Guoqing [1 ]
Shi, Jie [1 ]
Lu, Yongxing [1 ]
机构
[1] N China Elect Power Univ, Key Lab Condit Monitoring & Control Power Plant E, Minist Educ, Beijing 102206, Peoples R China
关键词
Boiler; leakage localizition; time differences of arrive; generalized cross correlation; accelerationg genetic algorithm; error;
D O I
10.1109/WCICA.2010.5553788
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Efficient and reliable operation is the main requirement of the modern power plant, hence it's significant that the boiler tube leakage source is localized precisely. The four-element acoustic array was exploited in the furnace and the schematic of sensors distributed for capture the leakage signal were given. A set of hyperbolic equations were established and Accelerating genetic algorithm (AGA) was proposed to give an iterative solution avoiding initial guess and far-field assumption. The stable and sharp peak can be obtained by an approximation of the maximum likelihood (ML) estimator, which was verified via the experiment on localization of leakage. The time differences of arrival (TDOA) error level was 0.1us, the array failed to fix position as the remarkable coordinate error, while the error level was 0.01us, the coordinates error was linearized and reduced to the permitted range (less than 1m).
引用
收藏
页码:3179 / 3183
页数:5
相关论文
共 50 条
  • [41] EVALUATION OF ACOUSTIC ENHANCEMENT IN AN HYBRID WATER/FIRE TUBE BOILER'S FURNACE BURNING EUCALYPTUS
    de Mello e Pinto, Luis Roberto
    Pedroso Correa, Paulo Sergio, Jr.
    Andrade, Rubenildo Vieira
    Silva Lora, Electo Eduardo
    Venturini, Osvaldo Jose
    Martinez Reyes, Arnaldo Martin
    Mendes Neto, Lourival Jorge
    Yepes Maya, Diego Mauricio
    Ratner, Albert
    PAPERS OF THE 25TH EUROPEAN BIOMASS CONFERENCE, 2017, : 634 - 641
  • [42] Acoustic radiation and cold point defect in boiler tube arrays based on phononic crystals theory
    Jiang, Genshan
    Liu, Yuechao
    Xu, Weilong
    Kong, Qian
    APPLIED THERMAL ENGINEERING, 2017, 123 : 746 - 752
  • [43] Boiler tube thermal failures
    不详
    MATERIALS PERFORMANCE, 2001, 40 (07) : 11 - 11
  • [44] An Overheat Boiler Tube Failure
    Perdomo, J. J.
    Spry, T. D.
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2005, 5 (02) : 25 - 28
  • [45] FIRE-TUBE BOILER
    MOORE, BR
    ENGINEERING, 1978, 218 (07): : 681 - 683
  • [46] FIRE-TUBE BOILER
    FOX, GR
    ENGINEERING, 1978, 218 (12): : 1281 - 1281
  • [47] Boiler tube panel saw
    Chief Engineer, 1998, 63 (07):
  • [48] PREVENT BOILER TUBE FAILURES
    CHERRY, KF
    EWALD, JD
    POLLUTION ENGINEERING, 1980, 12 (03) : 49 - 50
  • [49] BOILER TUBE FAILURES AND THEIR CAUSES
    DOOLEY, RB
    MAYER, P
    CIM BULLETIN, 1982, 75 (842): : 119 - 119
  • [50] BOILER TUBE INSPECTION METHODS
    GIBSON, G
    POWER ENGINEERING, 1975, 79 (10) : 38 - 42