Peripapillary Retinal Nerve Fiber Layer Thickness Determined by Spectral-Domain Optical Coherence Tomography in Ophthalmologically Normal Eyes

被引:86
|
作者
Hirasawa, Hiroyo
Tomidokoro, Atsuo [1 ]
Araie, Makoto
Konno, Shinsuke
Saito, Hitomi [2 ]
Iwase, Aiko [2 ]
Shirakashi, Motohiro [3 ]
Abe, Haruki [3 ]
Ohkubo, Shinji [4 ]
Sugiyama, Kazuhisa [4 ]
Ootani, Tomohiro [5 ]
Kishi, Shoji [5 ]
Matsushita, Kenji [6 ]
Maeda, Naoyuki [6 ]
Hangai, Masanori [7 ]
Yoshimura, Nagahisa [7 ]
机构
[1] Univ Tokyo, Dept Ophthalmol, Grad Sch Med, Bunkyo Ku, Tokyo 1138655, Japan
[2] Tajimi Municipal Hosp, Dept Ophthalmol, Tajimi, Japan
[3] Niigata Univ, Div Ophthalmol & Visual Sci, Grad Sch Med & Dent Sci, Niigata, Japan
[4] Kanazawa Univ, Dept Ophthalmol & Visual Sci, Grad Sch Med Sci, Kanazawa, Ishikawa, Japan
[5] Gunma Univ, Sch Med, Dept Ophthalmol, Maebashi, Gunma 371, Japan
[6] Osaka Univ, Sch Med, Dept Ophthalmol, Osaka, Japan
[7] Kyoto Univ, Dept Ophthalmol & Visual Sci, Grad Sch Med, Kyoto, Japan
关键词
SCANNING LASER POLARIMETRY; STRATUS OCT; CORNEAL COMPENSATION; GLAUCOMATOUS EYES; REFRACTIVE ERROR; OCULAR BIOMETRY; AXON DIAMETER; HIGH-SPEED; GDX VCC; REPRODUCIBILITY;
D O I
10.1001/archophthalmol.2010.244
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objectives: To evaluate the peripapillary distribution of retinal nerve fiber layer thickness (RNFLT) in normal eyes using spectral-domain optical coherence tomography and to study potentially related factors. Methods: In 7 institutes in Japan, RNFLT in 7 concentric peripapillary circles with diameters ranging from 2.2 to 4.0 mm were measured using spectral-domain optical coherence tomography in 251 ophthalmologically normal subjects. Multiple regression analysis for the association of RNFLT with sex, age, axial length, and disc area was performed. Results: Retinal nerve fiber layer thickness decreased linearly from 125 to 89 mu m as the measurement diameter increased (P<.001, mixed linear model). Retinal nerve fiber layer thickness correlated with age in all diameters (partial correlation coefficient [PCC]=-0.40 to -0.32; P<.001) and negatively correlated with disc area in the 2 innermost circles but positively correlated in the 3 outermost circles (PCC=-0.30 to -0.22 and 0.17 to 0.20; P <=.005). Sex and axial length did not correlate with RNFLT (P>.08). The decay slope was smallest in the temporal and largest in the nasal and inferior quadrants (P<.001); positively correlated with disc area (PCC=0.13 to 0.51; P <=.04); and negatively correlated with RNFLT (PCC=-0.51 to -0.15; P <=.01). Conclusions: In normal Japanese eyes, RNFLT significantly correlated with age and disc area, but not with sex or axial length. Retinal nerve fiber layer thickness decreased linearly as the measurement diameter increased. The decay slope of RNFLT was steepest in the nasal and inferior quadrants and steeper in eyes with increased RNFLT or smaller optic discs.
引用
收藏
页码:1420 / 1426
页数:7
相关论文
共 50 条
  • [31] Predicted and Measured Retinal Nerve Fiber Layer Thickness From Time-Domain Optical Coherence Tomography Compared With Spectral-Domain Optical Coherence Tomography
    Schrems, Wolfgang A.
    Schrems-Hoesl, LauraM.
    Bendschneider, Delia
    Mardin, Christian Y.
    Laemmer, Robert
    Kruse, Friedrich E.
    Horn, Folkert K.
    JAMA OPHTHALMOLOGY, 2015, 133 (10) : 1135 - 1143
  • [32] Peripapillary choroidal thickness assessed by spectral-domain optical coherence tomography in normal Japanese
    Hitomi Shibata
    Yu Sawada
    Makoto Ishikawa
    Takeshi Yoshitomi
    Takeshi Iwase
    Japanese Journal of Ophthalmology, 2021, 65 : 666 - 671
  • [33] Repeatability of Peripapillary Retinal Nerve Fiber Layer and Inner Retinal Thickness Among Two Spectral Domain Optical Coherence Tomography Devices
    Matlach, Juliane
    Wagner, Martin
    Malzahn, Uwe
    Goebel, Winfried
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (10) : 6536 - 6546
  • [34] Peripapillary choroidal thickness assessed by spectral-domain optical coherence tomography in normal Japanese
    Shibata, Hitomi
    Sawada, Yu
    Ishikawa, Makoto
    Yoshitomi, Takeshi
    Iwase, Takeshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2021, 65 (05) : 666 - 671
  • [35] Positional Independence of Optic Nerve Head and Retinal Nerve Fiber Layer Thickness Measurements With Spectral-Domain Optical Coherence Tomography
    Mansouri, Kaweh
    Liu, John H. K.
    Tafreshi, Ali
    Medeiros, Felipe A.
    Weinreb, Robert N.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 154 (04) : 712 - 721
  • [36] Retinal Nerve Fiber Layer Thickness and Visual Sensitivity Using Spectral-Domain and Time-Domain Optical Coherence Tomography
    Tavares, I. M.
    Jose, A. Kara
    Barbosa, D. V. C.
    Almeida, E. D., Jr.
    Leite, M. T.
    Endo, A. T. N. H.
    Santos, C. R. S.
    Melo, L. A. S., Jr.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [37] Peripapillary Retinal Nerve Fiber Layer Thickness in Normal Iranian Children Measured with Optical Coherence Tomography
    Eslami, Yadollah
    Vahedian, Zakieh
    Moghimi, Sasan
    Bazvand, Fatemeh
    Salari, Haniyeh
    Shahabinejad, Mojtaba
    Malekpoor, Afsaneh
    Fakhraie, Ghasem
    JOURNAL OF OPHTHALMIC & VISION RESEARCH, 2018, 13 (04) : 453 - 457
  • [38] Retinal Nerve Fiber Layer Thickness Measurement by Spectral-Domain Optical Coherence Tomography in Patients with Major Depressive Disorder
    Sonmez, Ipek
    Kosger, Ferdi
    Aykan, Umit
    NOROPSIKIYATRI ARSIVI-ARCHIVES OF NEUROPSYCHIATRY, 2017, 54 (01): : 62 - 66
  • [39] EVALUATION OF RETINAL NERVE FIBER LAYER THICKNESS IN PATIENTS WITH RETINITIS PIGMENTOSA USING SPECTRAL-DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Anastasakis, Anastasios
    Genead, Mohamed A.
    McAnany, J. Jason
    Fishman, Gerald A.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2012, 32 (02): : 358 - 363
  • [40] Comparison of Peripapillary Retinal Nerve Fiber Layer Thickness Measured by Spectral vs. Time Domain Optical Coherence Tomography
    Hong, Samin
    Seong, Gong Je
    Kim, Sung Soo
    Kang, Sung Yong
    Kim, Chan Yun
    CURRENT EYE RESEARCH, 2011, 36 (02) : 125 - 134