Development of a fast capillary electrophoresis method for determination of creatinine in urine samples

被引:34
|
作者
Costa, Ana Carolina O.
da Costa, Jose Luiz
Tonin, Fernando G.
Tavares, Marina F. M.
Micke, Gustavo Arnadeu [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Chem, BR-88040900 Florianopolis, SC, Brazil
[2] Criminalist Inst Sao Paulo, Instrumental Anal Lab, Sao Paulo, Brazil
[3] Univ Sao Paulo, Inst Chem, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
creatinine; short-end injection; human urine; optimization; peakmaster;
D O I
10.1016/j.chroma.2007.09.029
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The aim of this work was to develop a fast method using capillary electrophoresis for the determination of creatinine in human urine samples. The pH and constituents of the background electrolyte were selected by inspection of effective mobility of creatinine and candidate urine interferents versus pH curves. The tendency of the analyte to undergo electromigration dispersion and the buffer capacity were evaluated by the Peakmaster software and considered in the optimization of the background electrolyte, composed by 10mmolL(-1) tris(hydroxymethyl)aminomethane and 20 mmol L-1 2-hydroxyisobutyric acid (HIBA) at pH 3.93. Separation was conducted in a fused-silica capillary (32 cm total length and 8.5 cm effective length, 50 mu m I.D.), with short-end injection configuration and direct UV detection at 215 nm. The migration time of creatinine was only 22 s. A few figures of merit of the method are as follows: good linearity in the concentration interval of 5-70 mg L-1 (R 2 > 0.99), limit Of detection of 0.5 mg L-1, inter-day precision better than 2.7% (n = 9) and recovery in the range 99.0-103.7% at three concentration levels (50, 100 and 150 mg L-1). Urine samples were prepared by deproteination with acetonitrile (1:3 sample: acetonitrile, v/v), centrifugation and dilution of a deproteinated aliquot with 12.5 mmol L-1 HIBA (1:4, v/v). Creatinine concentrations between 489 and 1063 mg L-1 were obtained in the urine of four healthy volunteers. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:140 / 143
页数:4
相关论文
共 50 条
  • [21] Determination of opiates in urine by capillary electrophoresis
    Taylor, RB
    Low, AS
    Reid, RG
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 675 (02): : 213 - 223
  • [22] Development of a capillary zone electrophoresis method for caseinoglycomacropeptide determination
    Cherkaoui, S
    Doumenc, N
    Tachon, P
    Neeser, JR
    Veuthey, JL
    JOURNAL OF CHROMATOGRAPHY A, 1997, 790 (1-2) : 195 - 205
  • [23] Development of a robust, fast screening method for the potentiometric determination of iodide in urine and salt samples
    Machado, Ana
    Mesquita, Raquel B. R.
    Oliveira, Sara
    Bordalo, Adriano A.
    TALANTA, 2017, 167 : 688 - 694
  • [24] Development of a capillary electrophoresis method for the simultaneous determination of cephalosporins
    Hancu, Gabriel
    Kelemen, Hajnal
    Rusu, Aura
    Gyeresi, Arpad
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2013, 78 (09) : 1413 - 1423
  • [26] Development of an enzymeless electroanalytical method for the indirect detection of creatinine in urine samples
    de Araujo, William R.
    Salles, Maiara O.
    Paixao, Thiago R. L. C.
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 173 : 847 - 851
  • [27] Determination of Oxymatrine in Urine Samples by Capillary Electrophoresis with Stacking Induced by Moving Reaction Boundary
    Wang Xing
    Zhang Wei
    Fan Liuyin
    Cao Chengxi
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (05) : 694 - 698
  • [28] Development and validation of a capillary zone electrophoresis method for the determination of ephedrine and related compounds in urine without extraction
    Mateus-Avois, L
    Mangin, P
    Saugy, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 791 (1-2): : 203 - 216
  • [29] Analysis of nitrite in adulterated urine samples by capillary electrophoresis
    Kinkennon, AE
    Black, DL
    Robert, TA
    Stout, PR
    JOURNAL OF FORENSIC SCIENCES, 2004, 49 (05) : 1094 - 1100
  • [30] Glyoxylate determination in rat urine by capillary electrophoresis
    Nishijima, S
    Miyazato, T
    Sugaya, K
    Koyama, Y
    Hatano, T
    Ogawa, Y
    INTERNATIONAL JOURNAL OF UROLOGY, 2001, 8 (08) : S63 - S67