A Universal Blown Film Apparatus for in Situ X-ray Measurements

被引:17
|
作者
Zhang, Rui
Ji, You-xin [1 ]
Zhang, Qian-lei
Ju, Jian-zhu
Sarmad, Ali
Li, Li-fu
Zhao, Hao-yuan
Li, Liang-bin [1 ]
机构
[1] Univ Sci & Technol China, Natl Synchrotron Radiat Lab, Hefei 230029, Anhui, Peoples R China
关键词
Blown film machine; Synchrotron radiation X-ray diffraction; In situ measurement; Structure evolution; LOW-DENSITY POLYETHYLENE; RAMAN-SPECTROSCOPY; MELT STRENGTH; ORIENTATION; SCATTERING; EXTRUSION; CRYSTALLIZATION; DIFFRACTION; BIREFRINGENCE; EVOLUTION;
D O I
10.1007/s10118-017-2000-z
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
A setup of blown film machine combined with in situ synchrotron radiation X-ray diffraction measurements and infrared temperature testing is reported to study the structure evolution of polymers during film blowing. Two homemade auto-lifters are constructed and placed under the blown machine at each end of the beamline platform which move up and down with a speed of 0.05 mm/s bearing the 200 kg weight machine. Therefore, structure development and temperature changes as a function of position on the film bubble can be obtained. The blown film machine is customized to be conveniently installed with precise servo motors and can adjust the processing parameters in a wide range. Meanwhile, the air ring has been redesigned in order to track the structure information of the film bubble immediately after the melt being extruded out from the die exit. Polyethylene (PE) is selected as a model system to verify the feasibility of the apparatus and the in situ experimental techniques. Combining structure information provided by the WAXD and SAXS and the actual temperature obtained from the infrared probe, a full roadmap of structure development during film blowing is constructed and it is helpful to explore the molecular mechanism of structure evolution behind the film blowing processing, which is expected to lead to a better understanding of the physics in polymer processing.
引用
收藏
页码:1508 / 1516
页数:9
相关论文
共 50 条
  • [41] A new X-ray apparatus with complete X-ray and electrical protection
    Bouwers, A
    ACTA RADIOLOGICA, 1928, 9 (06) : 600 - 605
  • [42] X-ray film measurements for healed distal radius fractures
    Kreder, HJ
    Hanel, DP
    McKee, M
    Jupiter, J
    McGillivary, G
    Swiontkowski, MF
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (01): : 31 - 39
  • [43] Metallic thin film depth measurements by X-ray microanalysis
    Ng, FL
    Wei, J
    Lai, FK
    Goh, KL
    APPLIED SURFACE SCIENCE, 2006, 252 (11) : 3972 - 3976
  • [44] Oxidation study of polycrystalline InN film using in situ X-ray scattering and X-ray photoemission spectroscopy
    Lee, Ik Jae
    Yu, Chungjong
    Shin, Hyun-Joon
    Kim, Jae-Yong
    Lee, Young Pak
    Hur, Tae-Bong
    Kim, Hyung-Kook
    THIN SOLID FILMS, 2007, 515 (11) : 4691 - 4695
  • [45] In Situ X-ray Tomography and 3D X-ray Diffraction Measurements of Cemented Granular Materials
    C. Zhai
    D. C. Pagan
    R. C. Hurley
    JOM, 2020, 72 : 18 - 27
  • [46] In Situ X-ray Tomography and 3D X-ray Diffraction Measurements of Cemented Granular Materials
    Zhai, C.
    Pagan, D. C.
    Hurley, R. C.
    JOM, 2020, 72 (01) : 18 - 27
  • [47] OUTLINE OF UNIVERSAL GYROSCOPIC X-RAY TELEVISION APPARATUS (GYROSCOPE) AND ITS CLINICAL VALUE
    KUROKAWA, T
    SAITO, T
    NISHIYAMA, S
    PROCEEDINGS OF THE JAPAN ACADEMY, 1977, 53 (02): : 87 - 90
  • [48] Simultaneous in situ measurements of x-ray reflectivity and optical spectroscopy during organic semiconductor thin film growth
    Hosokai, T.
    Gerlach, A.
    Hinderhofer, A.
    Frank, C.
    Ligorio, G.
    Heinemeyer, U.
    Vorobiev, A.
    Schreiber, F.
    APPLIED PHYSICS LETTERS, 2010, 97 (06)
  • [49] An automatic x-ray diffraction apparatus
    Davey, WP
    Smith, FR
    Harding, SW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1944, 15 (02): : 37 - 45
  • [50] X-ray apparatus at health centres
    Collier, HE
    BRITISH MEDICAL JOURNAL, 1943, 1943 : 234 - 234