Optical coherence tomography, frequency-doubling technology, and colour Doppler imaging in ocular hypertension

被引:7
|
作者
Cellini, M. [1 ]
Bernabini, B. [1 ]
Carbonelli, M. [1 ]
Zamparini, E. [1 ]
Campos, E. C. [1 ]
机构
[1] Univ Bologna, Dept Surg & Transplant, Ophthalmol Serv, I-40138 Bologna, Italy
关键词
optical coherence tomography; frequency-doubling technology; colour Doppler imaging; ocular hypertension; retinal nerve fibre layer;
D O I
10.1038/sj.eye.6702412
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To study in ocular hypertension (OH) the retinal nerve fibre layer (RNFL) with optical coherence tomography (OCT) and the neuronal function with frequency-doubling technology (FDT) to assess which of the two methods was more sensitive in detecting early glaucomatous damage. Furthermore, a colour Doppler imaging (CDI) of the optic nerve was carried out to highlight any correlation with RNFL thickness and FDT abnormality. Materials and methods We enrolled 28 ocular hypertensive patients who underwent OCT of the RNFL and FDT. Moreover, we performed a CDI of the ophthalmic artery (OA), central retinal artery (CRA), and posterior ciliary arteries (PCAs). Results The patients with OH following OCT revealed a significant thinning in the RNFL as compared to the control group only in the inferior quadrant: 122.250 +/- 14.091 vs 131.750 +/- 10.729 mu m (P < 0.045). As regards FDT, there was a significant difference between the two groups only for pattern standard deviation (PSD): 3.873 +/- 1.488 vs 1.938 +/- 0.704 dB (P < 0.044). In OH and in the control group, CDI resistance index (RI) in the OA was 0.768 +/- 0.012 vs 0.745 +/- 0.019 (P < 0.022), in the CRA was 0.66 +/- 0.012 vs 0.645 +/- 0.019 (P < 0.032), and in PCAs was 0.673 +/- 0.039 vs 0.622 +/- 0.012 (P < 0.037). The OCT had a sensitivity of 83% but only in the inferior RNFL quadrant. The FDT-PSD revealed a sensitivity of 85%. Conclusions Both FDT and OCT detect early glaucomatous damage with a slightly superior sensitivity of FDT vs OCT. The CDI measurements suggest that circulatory abnormalities may have a role in the development of OCT and FDT damage.
引用
收藏
页码:1071 / 1077
页数:7
相关论文
共 50 条
  • [21] IMAGING THE NONLINEAR GRATING IN FREQUENCY-DOUBLING FIBERS
    MARGULIS, W
    LAURELL, F
    LESCHE, B
    NATURE, 1995, 378 (6558) : 699 - 701
  • [22] Phase resolved optical coherence tomography and optical Doppler tomography: Technology and applications
    Chen, ZP
    Zhao, YH
    Nelson, JS
    SARATOV FALL MEETING 2000: OPTICAL TECHNOLOGIES IN BIOPHYSICS AND MEDICINE II, 2001, 4241 : 182 - 185
  • [23] Optical coherence tomography imaging of ocular and periocular tumours
    Medina, Carlos A.
    Plesec, Thomas
    Singh, Arun D.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2014, 98 : 40 - 46
  • [24] Optical coherence tomography, not "ocular" coherence tomography
    Huang, David
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (07): : 1141 - 1141
  • [25] Mechanisms Underlying Frequency-Doubling Technology (FDT) in Glaucoma
    Lee, Michele
    Wielaard, James
    Acton, Jennifer
    Boddu, Sucharita
    Park, Sung Chul
    Liebmann, Jeffrey
    Smith, Roland
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [26] Optical Coherence Tomography (OCT) Imaging Technology
    Milanovic, Ljubica
    Milenkovic, Strahinja
    Petrovic, Nenad
    Grujovic, Nenad
    Slavkovic, Vukasin
    Zivic, Fatima
    2021 IEEE 21ST INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (IEEE BIBE 2021), 2021,
  • [27] The evaluation of juvenile ocular hypertension by optical coherence tomography angiography
    Xiaoxiao Chen
    Xiaolei Wang
    Xinxin Hu
    Xinghuai Sun
    BMC Ophthalmology, 20
  • [28] The evaluation of juvenile ocular hypertension by optical coherence tomography angiography
    Chen, Xiaoxiao
    Wang, Xiaolei
    Hu, Xinxin
    Sun, Xinghuai
    BMC OPHTHALMOLOGY, 2020, 20 (01)
  • [29] Impact of cataract on the results of frequency-doubling technology perimetry
    Tanna, AP
    Abraham, C
    Lai, J
    Shen, J
    OPHTHALMOLOGY, 2004, 111 (08) : 1504 - 1507
  • [30] Screening for glaucoma with frequency-doubling technology and Damato campimetry
    Yamada, N
    Chen, PP
    Mills, RP
    Leen, MM
    Lieberman, MF
    Stamper, RL
    Stanford, DC
    ARCHIVES OF OPHTHALMOLOGY, 1999, 117 (11) : 1479 - 1484