Optical coherence tomography, frequency-doubling technology, and colour Doppler imaging in ocular hypertension

被引:7
|
作者
Cellini, M. [1 ]
Bernabini, B. [1 ]
Carbonelli, M. [1 ]
Zamparini, E. [1 ]
Campos, E. C. [1 ]
机构
[1] Univ Bologna, Dept Surg & Transplant, Ophthalmol Serv, I-40138 Bologna, Italy
关键词
optical coherence tomography; frequency-doubling technology; colour Doppler imaging; ocular hypertension; retinal nerve fibre layer;
D O I
10.1038/sj.eye.6702412
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To study in ocular hypertension (OH) the retinal nerve fibre layer (RNFL) with optical coherence tomography (OCT) and the neuronal function with frequency-doubling technology (FDT) to assess which of the two methods was more sensitive in detecting early glaucomatous damage. Furthermore, a colour Doppler imaging (CDI) of the optic nerve was carried out to highlight any correlation with RNFL thickness and FDT abnormality. Materials and methods We enrolled 28 ocular hypertensive patients who underwent OCT of the RNFL and FDT. Moreover, we performed a CDI of the ophthalmic artery (OA), central retinal artery (CRA), and posterior ciliary arteries (PCAs). Results The patients with OH following OCT revealed a significant thinning in the RNFL as compared to the control group only in the inferior quadrant: 122.250 +/- 14.091 vs 131.750 +/- 10.729 mu m (P < 0.045). As regards FDT, there was a significant difference between the two groups only for pattern standard deviation (PSD): 3.873 +/- 1.488 vs 1.938 +/- 0.704 dB (P < 0.044). In OH and in the control group, CDI resistance index (RI) in the OA was 0.768 +/- 0.012 vs 0.745 +/- 0.019 (P < 0.022), in the CRA was 0.66 +/- 0.012 vs 0.645 +/- 0.019 (P < 0.032), and in PCAs was 0.673 +/- 0.039 vs 0.622 +/- 0.012 (P < 0.037). The OCT had a sensitivity of 83% but only in the inferior RNFL quadrant. The FDT-PSD revealed a sensitivity of 85%. Conclusions Both FDT and OCT detect early glaucomatous damage with a slightly superior sensitivity of FDT vs OCT. The CDI measurements suggest that circulatory abnormalities may have a role in the development of OCT and FDT damage.
引用
收藏
页码:1071 / 1077
页数:7
相关论文
共 50 条
  • [1] Optical coherence tomography, frequency-doubling technology, and colour Doppler imaging in ocular hypertension
    M Cellini
    B Bernabini
    M Carbonelli
    E Zamparini
    E C Campos
    Eye, 2007, 21 : 1071 - 1077
  • [2] Frequency doubling technology, optical coherence technology and pattern electroretinogram in ocular hypertension
    Mauro Cellini
    Pier Giorgio Toschi
    Ernesto Strobbe
    Nicole Balducci
    Emilio C Campos
    BMC Ophthalmology, 12
  • [3] Frequency doubling technology, optical coherence technology and pattern electroretinogram in ocular hypertension
    Cellini, Mauro
    Toschi, Pier Giorgio
    Strobbe, Ernesto
    Balducci, Nicole
    Campos, Emilio C.
    BMC OPHTHALMOLOGY, 2012, 12
  • [4] Structure-Function Relationship between Frequency-Doubling Technology Perimetry and Optical Coherence Tomography in Glaucoma
    Fuertes-Lazaro, Isabel
    Sanchez-Cano, Ana
    Ferreras, Antonio
    Ferrandez, Blanca
    Calvo, Pilar
    Abadia, Beatriz
    Otin, Sofia
    Pablo, Luis E.
    OPHTHALMOLOGICA, 2014, 232 (04) : 230 - 238
  • [5] Frequency-doubling technology and retinal measurements with spectral-domain optical coherence tomography in preperimetric glaucoma
    Hirashima, Takafumi
    Hangai, Masanori
    Nukada, Masayuki
    Nakano, Noriko
    Morooka, Satoshi
    Akagi, Tadamichi
    Nonaka, Atsushi
    Yoshimura, Nagahisa
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (01) : 129 - 137
  • [6] Frequency-doubling technology and retinal measurements with spectral-domain optical coherence tomography in preperimetric glaucoma
    Takafumi Hirashima
    Masanori Hangai
    Masayuki Nukada
    Noriko Nakano
    Satoshi Morooka
    Tadamichi Akagi
    Atsushi Nonaka
    Nagahisa Yoshimura
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2013, 251 : 129 - 137
  • [7] Hemifield pattern electroretinogram in ocular hypertension: comparison with frequency doubling technology and optical coherence tomography to detect early optic neuropathy
    Finzi, Alessandro
    Strobbe, Ernesto
    Tassi, Filippo
    Fresina, Michela
    Cellini, Mauro
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 1929 - 1936
  • [8] Frequency-doubling technology and high-pass resolution perimetry in glaucoma and ocular hypertension
    Kalaboukhova, LV
    Lindblom, B
    PERIMETRY UPDATE 2002/2003, 2004, : 147 - 147
  • [9] Frequency-doubling technology perimetry and optical defocus
    Anderson, AJ
    Johnson, CA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (09) : 4147 - 4152
  • [10] Structural and Functional Assessment in Patients Treated with Systemic Isotretinoin Using Optical Coherence Tomography and Frequency-Doubling Technology Perimetry
    Bakbak, Berker
    Gedik, Sansal
    Koktekir, Bengu Ekinci
    Guzel, Huseyin
    Altinyazar, Hilmi Cevdet
    NEURO-OPHTHALMOLOGY, 2013, 37 (03) : 100 - 103