Evaluation of clinical effectiveness of the Frova single-use tracheal tube introducer

被引:45
|
作者
Hodzovic, I. [1 ]
Wilkes, A. R.
Stacey, M. [2 ]
Latto, I. P. [2 ]
机构
[1] Cardiff Univ, Wales Coll Med, Dept Anaesthesia & Intens Care Med, Cardiff, S Glam, Wales
[2] Univ Wales Hosp, Cardiff CF4 4XW, S Glam, Wales
关键词
GUM-ELASTIC BOUGIE; SIMULATED DIFFICULT INTUBATION; MULTIPLE-USE; AIRWAY; MANAGEMENT; GUIDELINES; MANNEQUIN; TRAUMA;
D O I
10.1111/j.1365-2044.2007.05322.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A prospective observational study design was used to evaluate the clinical effectiveness of the Frova single-use tracheal tube introducer. Data were collected from 203 patients. Consultants and trainee anaesthetists completed 61 (30%) and 142 (70%) forms respectively, when the Frova introducer was used. It was successfully placed in the trachea in 194/203 (96%) of patients with two attempts at placement by the first clinician. The first clinician failed to either pass the Frova introducer or railroad the tube in six (3%) and 10 (5%) of the 203 patients respectively. The success rate by the first clinician was significantly influenced by the laryngeal view obtained (p < 0.0001). There was only one failure to place the Frova introducer in the trachea by either the first or second clinician. Airway trauma was detected in 11/203 (5%) patients. In six of these 11 patients blood was detected on tracheal suction; 'distal hold up' was elicited in five of these six. The Frova introducer has a high success rate for tracheal placement but has noteworthy potential to produce airway trauma.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 50 条
  • [21] What is Best Testing Ground for Clinical Evaluation of Single-use Duodenoscopes? Reply
    Muthusamy, V. Raman
    Ross, Andrew S.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2020, 18 (08) : 1900 - 1901
  • [22] Clinical evaluation of a novel single-use therapeutic gastroscope: a pilot feasibility study
    Roemmele, Christoph
    Ayoub, Mousa
    Wanzl, Julia
    Tadic, Vidan
    Braun, Georg
    Weber, Tobias
    Scheppach, Markus Wolfgang
    Roser, David
    Matic, Katharina
    Nagl, Sandra
    Messmann, Helmut
    Ebigbo, Alanna
    ENDOSCOPY, 2024,
  • [23] The LTD™ laryngeal tube:: a new single-use airway device
    Langlois, C.
    Pean, D.
    Testa, S.
    Beliard, C.
    Moreau, D.
    Lejus, C.
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2007, 26 (03): : 197 - 201
  • [24] EVALUATION OF SINGLE-USE PACKS OF HOSPITAL DISINFECTANTS
    FARRAND, RJ
    WILLIAMS, A
    LANCET, 1973, 1 (7803): : 591 - 593
  • [25] Evaluation of a Novel Single-Use Flexible Ureteroscope
    Dale, Joanne
    Kaplan, Adam G.
    Radvak, Daniela
    Shin, Richard
    Ackerman, Anika
    Chen, Tony
    Scales, Charles D., Jr.
    Ferrandino, Michael N.
    Simmons, Walter Neal
    Preminger, Glenn M.
    Lipkin, Michael E.
    JOURNAL OF ENDOUROLOGY, 2021, 35 (06) : 903 - 907
  • [26] Environmental evaluation of single-use and reusable cups
    Garrido, Nuria
    Alvarez del Castillo, M. Dolors
    INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2007, 12 (04): : 252 - 256
  • [27] The single-use rhinolaryngoscope: an evaluation and cost comparison
    Mistry, R.
    Russell, R., V
    Walker, N.
    Ofo, E.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2020, 134 (09): : 790 - 797
  • [28] Environmental evaluation of single-use and reusable cups
    Nuria Garrido
    M. Dolors Alvarez del Castillo
    The International Journal of Life Cycle Assessment, 2007, 12 : 252 - 256
  • [29] Evaluation of single-use bioreactors for perfusion processes
    Clutterbuck, Andrew
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2014, 247
  • [30] Evaluation of single-use bioreactors for perfusion processes
    Aurore Polès-Lahille
    Flavien Thuet
    David Balbuena
    Sébastien Ribault
    BMC Proceedings, 7 (Suppl 6)