Evaluation of clinical effectiveness of the Frova single-use tracheal tube introducer

被引:45
|
作者
Hodzovic, I. [1 ]
Wilkes, A. R.
Stacey, M. [2 ]
Latto, I. P. [2 ]
机构
[1] Cardiff Univ, Wales Coll Med, Dept Anaesthesia & Intens Care Med, Cardiff, S Glam, Wales
[2] Univ Wales Hosp, Cardiff CF4 4XW, S Glam, Wales
关键词
GUM-ELASTIC BOUGIE; SIMULATED DIFFICULT INTUBATION; MULTIPLE-USE; AIRWAY; MANAGEMENT; GUIDELINES; MANNEQUIN; TRAUMA;
D O I
10.1111/j.1365-2044.2007.05322.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A prospective observational study design was used to evaluate the clinical effectiveness of the Frova single-use tracheal tube introducer. Data were collected from 203 patients. Consultants and trainee anaesthetists completed 61 (30%) and 142 (70%) forms respectively, when the Frova introducer was used. It was successfully placed in the trachea in 194/203 (96%) of patients with two attempts at placement by the first clinician. The first clinician failed to either pass the Frova introducer or railroad the tube in six (3%) and 10 (5%) of the 203 patients respectively. The success rate by the first clinician was significantly influenced by the laryngeal view obtained (p < 0.0001). There was only one failure to place the Frova introducer in the trachea by either the first or second clinician. Airway trauma was detected in 11/203 (5%) patients. In six of these 11 patients blood was detected on tracheal suction; 'distal hold up' was elicited in five of these six. The Frova introducer has a high success rate for tracheal placement but has noteworthy potential to produce airway trauma.
引用
收藏
页码:189 / 194
页数:6
相关论文
共 50 条
  • [1] Evaluation of Frova, single-use intubation introducer, in a manikin. Comparison with Eschmann multiple-use introducer and Portex single-use introducer
    Hodzovic, I
    Latto, IP
    Wilkes, AR
    Hall, JE
    Mapleson, WW
    ANAESTHESIA, 2004, 59 (08) : 811 - 816
  • [2] Randomized clinical trial of the i-gel™ and Magill tracheal tube or single-use ILMA™ and ILMA™ tracheal tube for blind intubation in anaesthetized patients with a predicted difficult airway
    Theiler, L.
    Kleine-Brueggeney, M.
    Urwyler, N.
    Graf, T.
    Luyet, C.
    Greif, R.
    BRITISH JOURNAL OF ANAESTHESIA, 2011, 107 (02) : 243 - 250
  • [3] INVITRO EVALUATION OF ACCURACY OF A SINGLE-USE CLINICAL THERMOMETER
    BESLEY, LM
    KEMP, RC
    MEDICAL JOURNAL OF AUSTRALIA, 1978, 2 (07) : 337 - 339
  • [4] Evaluation of the novel, single-use, flexible aScope® for tracheal intubation in the simulated difficult airway and first clinical experiences
    Piepho, T.
    Werner, C.
    Noppens, R. R.
    ANAESTHESIA, 2010, 65 (08) : 820 - 825
  • [5] Use of a tracheal tube introducer guide to facilitate difficult intubation with a video laryngoscope
    Glenn P. McGuire
    Tze Ping Tan
    David T. Wong
    Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2014, 61 : 682 - 683
  • [6] Use of a tracheal tube introducer guide to facilitate difficult intubation with a video laryngoscope
    McGuire, Glenn P.
    Tan, Tze Ping
    Wong, David T.
    CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2014, 61 (07): : 682 - 683
  • [7] Use of the Coopdech Bronchial Blocker™ as a tracheal tube introducer in a patient with difficult laryngoscopy
    Masayuki Ozaki
    Koji Murashima
    Kazunori Koga
    Takeyoshi Sata
    Journal of Anesthesia, 2010, 24 : 319 - 320
  • [8] Use of a modified McGRATH MAC and tracheal tube introducer for difficult nasal intubation
    Kido, Haruki
    Komasawa, Nobuyasu
    Ishio, Junichi
    Minami, Toshiaki
    JOURNAL OF CLINICAL ANESTHESIA, 2016, 34 : 255 - 256
  • [9] Use of the Coopdech Bronchial Blocker™ as a tracheal tube introducer in a patient with difficult laryngoscopy
    Ozaki, Masayuki
    Murashima, Koji
    Koga, Kazunori
    Sata, Takeyoshi
    JOURNAL OF ANESTHESIA, 2010, 24 (02) : 319 - 320
  • [10] Tracheal trauma secondary to the use of a Portex single-use bougie
    Heidemann, BH
    Clark, VA
    ANAESTHESIA, 2004, 59 (10) : 1043 - 1044