Effect of anatomical backgrounds on detectability in volumetric cone beam CT images

被引:1
|
作者
Han, Minah [1 ,2 ]
Park, Subok [3 ]
Baek, Jongduk [1 ,2 ]
机构
[1] Yonsei Univ, Sch Integrated Technol, Seoul 120749, South Korea
[2] Yonsei Univ, Yonsei Inst Convergence Technol, Seoul 120749, South Korea
[3] US FDA, Div Imaging Diagnost & Software Reliabil, OSEL, CDRH, Silver Spring, MD USA
来源
MEDICAL IMAGING 2016: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT | 2016年 / 9787卷
关键词
OBSERVER; CHANNELS; NOISE;
D O I
10.1117/12.2214689
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
As anatomical noise is often a dominating factor affecting signal detection in medical imaging, we investigate the effects of anatomical backgrounds on signal detection in volumetric cone beam CT images. Signal detection performances are compared between transverse and longitudinal planes with either uniform or anatomical backgrounds. Sphere objects with diameters of 1mm, 5mm, 8mm, and 11mm are used as the signals. Three-dimensional (3D) anatomical backgrounds are generated using an anatomical noise power spectrum, 1/f(beta), with beta=3, equivalent to mammographic background [1]. The mean voxel value of the 3D anatomical backgrounds is used as an attenuation coefficient of the uniform background. Noisy projection data are acquired by the forward projection of the uniform and anatomical 3D backgrounds with/without sphere lesions and by the addition of quantum noise. Then, images are reconstructed by an FDK algorithm [2]. For each signal size, signal detection performances in transverse and longitudinal planes are measured by calculating the task SNR of a channelized Hotelling observer with Laguerre-Gauss channels. In the uniform background case, transverse planes yield higher task SNR values for all sphere diameters but 1mm. In the anatomical background case, longitudinal planes yield higher task SNR values for all signal diameters. The results indicate that it is beneficial to use longitudinal planes to detect spherical signals in anatomical backgrounds.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Influence of anatomical location on CT numbers in cone beam computed tomography
    Oliveira, Matheus L.
    Tosoni, Guilherme M.
    Lindsey, David H.
    Mendoza, Kristopher
    Tetradis, Sotirios
    Mallya, Sanjay M.
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (04): : 558 - 564
  • [22] Dose and detectability for a cone-beam C-arm CT system revisited
    Ganguly, Arundhuti
    Yoon, Sungwon
    Fahrig, Rebecca
    MEDICAL PHYSICS, 2010, 37 (05) : 2264 - 2268
  • [23] Noise Properties in Helical Cone-beam CT Images
    Xia, Dan
    Sidky, Emil Y.
    Yu, Lifeng
    Pan, Xiaochuan
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3428 - 3430
  • [24] DENTAL ANATOMY SEGMENTATION FROM CONE BEAM CT IMAGES
    Tan, Minhui
    Fang, Yu
    Ma, Lei
    Zhang, Yu
    Cui, Zhiming
    Shen, Dinggang
    2023 IEEE 20TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, ISBI, 2023,
  • [25] Automatic segmentation of maxillofacial cysts in cone beam CT images
    Abdolali, Fatemeh
    Zoroofi, Reza Aghaeizadeh
    Otake, Yoshito
    Sato, Yoshinobu
    COMPUTERS IN BIOLOGY AND MEDICINE, 2016, 72 : 108 - 119
  • [26] Automatic Detection of Calcifications in Cone Beam Breast CT Images
    Han, T.
    Chen, L.
    Zhong, Y.
    Lai, C.
    Liu, X.
    Shen, Y.
    Yi, Y.
    Ge, S.
    You, Z.
    Wang, T.
    Shaw, C.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [27] Glandular segmentation of cone beam breast CT volume images
    Packard, Nathan
    Boone, John M.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [28] Effect of voxel size and partial volume effect on accuracy of tooth volumetric measurements with cone beam CT: Author response
    Peters, O.
    Maret, D.
    DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
  • [29] Anatomical evaluation of the craniovertebral junction on cone-beam computed tomography images
    Sefkan Tanrisever
    Mustafa Orhan
    İlhan Bahşi
    Eda Didem Yalçin
    Surgical and Radiologic Anatomy, 2020, 42 : 797 - 815
  • [30] ANATOMICAL CHARACTERISTICS OF NASOPALATINE CANAL USING CONE BEAM COMPUTED TOMOGRAPHY IMAGES
    Panahi, S. R.
    Sabz, G.
    Jokartangkarami, A.
    Afroughi, S.
    Kaimpour, F.
    NEW ARMENIAN MEDICAL JOURNAL, 2022, 16 (01): : 101 - 108