A Study on Mass Concentration Determination and Property Variations of Produced Polyacrylamide in Polymer Flooding

被引:14
|
作者
Qing, Y. [1 ,2 ]
Caili, D. [2 ]
Yefei, W. [2 ]
Engao, T. [3 ]
Guang, Y. [3 ]
Fulin, Z. [2 ]
机构
[1] Peking Univ, Sch Earth & Space Sci, Beijing 100871, Peoples R China
[2] China Univ Petr, Sch Petr Engn, Qingdao, Shandong, Peoples R China
[3] CNOOC, Res Inst, Beijing, Peoples R China
基金
中国博士后科学基金;
关键词
degree of hydrolysis; determination; mass concentration; polymer flooding; produced polyacrylamide; relative molecular mass; ultrafiltration; OIL-FIELD; ULTRAFILTRATION; HYDROLYSIS;
D O I
10.1080/10916461003752496
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Because injected polyacrylamide often quickly breaks through to production wells during polymer flooding, its mass concentration determination is very significant. However, due to the variations of relative molecular mass and degree of hydrolysis of produced polyacrylamide, the conventional determination methods, including viscosimetry and starch-cadmium iodide colorimetry, are no longer suitable for determining its real mass concentration. A new determination methodultrafiltration concentration film dryingis proposed and developed in this article. By purifying and concentrating produced polyacrylamide solution using an ultrafiltration system and then dehydrating water to a constant weight, this method can determine the mass concentration directly. This method has been evaluated in the laboratory and compared with two conventional determination methods, verifying its adaptability and high accuracy. The produced polyacrylamides from three different polymer flooding blocks have been determined using this new method. The results show that the relative molecular mass of produced polyacrylamide decreased greatly and its degree of hydrolysis increased obviously. The reasons and differences have been also analyzed. These corresponding variations make the results determined by the conventional methods much lower than the actual results, and it is implied that the previous methods need to be improved or replaced.
引用
收藏
页码:227 / 235
页数:9
相关论文
共 50 条
  • [41] Rapid determination of apixaban concentration in human plasma by liquid chromatography/tandem mass spectrometry: Application to pharmacokinetic study
    Delavenne, Xavier
    Mismetti, Patrick
    Basset, Thierry
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 78-79 : 150 - 153
  • [42] Laboratory study of polymer injection into heavy oil unconventional reservoirs to enhance oil recovery and determination of optimal injection concentration
    Tehrani, Pezhman Soltani
    Ghorbani, Hamzeh
    Lajmorak, Sahar
    Molaei, Omid
    Radwan, Ahmed E.
    Ghaleh, Saeed Parvizi
    AIMS GEOSCIENCES, 2022, 8 (04): : 579 - 592
  • [43] Determination of motolimod concentration in rat plasma by liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Ji, Yu-Geun
    Shin, Yu-Mi
    Jeong, Jong-Woo
    Choi, Hae-In
    Lee, Seung-Won
    Lee, Jong-Hwa
    Lee, Kyeong-Ryoon
    Koo, Tae-Sung
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 179
  • [44] DETERMINATION OF THE CONCENTRATION AND MOLECULAR MASS OF CIRCULATING IMMUNE-COMPLEXES .2. STUDY OF SOME CHARACTERISTICS OF IMMUNE-COMPLEXES
    KONSTANTINOVA, NA
    LAVRENTYEV, VV
    POBEDINSKAYA, LK
    LABORATORNOE DELO, 1986, (08): : 487 - 490
  • [45] Study of heterogeneities in steels and determination of soluble and total aluminium and titanium concentration by laser ablation inductively coupled plasma mass spectrometry
    Coedo, Aurora G.
    Dorado, Teresa
    Padilla, Isabel
    Farinas, Juan C.
    TALANTA, 2007, 71 (05) : 2108 - 2120
  • [46] Determination of site-site distance and site concentration within polymer beads: A combined swelling-electron paramagnetic resonance study
    Marchetto, R
    Cilli, EM
    Jubilut, GN
    Schreier, S
    Nakaie, CR
    JOURNAL OF ORGANIC CHEMISTRY, 2005, 70 (12): : 4561 - 4568
  • [47] Determination of molecular mass and concentration of a non-ionic block co-polymer (Poe-Pop-Poe) by high performance GPC with light scattering/refractive index detection.
    Nguyen, MA
    Sweeney, JA
    Tsai, PK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2004, 228 : U200 - U200
  • [49] A Sensitive Liquid Chromatography-Mass Spectrometry Method for Determination of 14-Deoxy-12(R)-Sulfo Andrographolide Concentration in Rat Plasma and its Application to a Pharmacokinetic Study
    Yang, Ruopeng
    Hu, Wanyu
    Xie, Cong
    Tang, Dafu
    Zhao, Xiaojie
    Fu, Bingxuan
    Wu, Jianming
    Ye, Ling
    Liao, Rongxin
    CURRENT DRUG METABOLISM, 2022, 23 (11) : 905 - 911
  • [50] Investigation of the use of immobilised metal affinity chromatography for the on-line sample clean up and pre-concentration of nucleotides prior to their determination by ion pair liquid chromatography-electrospray mass spectrometry:: a pilot study
    Tuytten, R
    Lemière, F
    Van Dongen, W
    Slegers, H
    Newton, RP
    Esmans, EL
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 809 (02): : 189 - 198