摘要
An on-line procedure for the simultaneous determination of bromine and total bromine (bromine+bromide oxidised to bromine) is proposed, which lead to the determination of bromide by subtraction. Phenol red was used as chromogenic reagent for bromine and total bromine after bromide was oxidised to bromine by Chloramine T. The linear range found is 1-10 mg L-1 with a detection limit of 0.6 mg L-1 for bromine, and a linear range of 0.8-15 mg L-1 with a detection limit of 0.4 mg L-1 for total bromine. The calculated RSD for bromine is less than 0.8% and for total bromine less than 0.7%. The system is fully computerised and able to run 30 samples per hour with an automated rinsing step that eliminates sample carry-over. The results for both bromine and bromide from the proposed sequential injection analysis (SIA) system compare favourably with standard manual methods and statistical evaluation proves no significant difference between the results of the proposed SIA system and the standard method at the 95% confidence level. The presence of other halides was found not to interfere.
引用
收藏
页码:1074 / 1082
页数:9
相关论文
共 50 条
  • [31] On-line monitoring of R-captopril using an amperometric biosensor/sequential injection analysis system
    Stefan, RI
    van Staden, JF
    Aboul-Enein, HY
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2002, 30 (03) : 243 - 250
  • [32] Kinetic Spectrophotometric Determination of Total Iron in Natural Water by Flow Injection Analysis Using On-Line Preconcentration
    Suling Feng
    Zhijun Guo
    Jing Fan
    Xingguo Chen
    Junying Sun
    Microchimica Acta, 2005, 149 : 61 - 65
  • [33] Kinetic spectrophotometric determination of total iron in natural water by flow injection analysis using on-line preconcentration
    Feng, SL
    Guo, ZJ
    Fan, J
    Chen, XG
    Sun, JY
    MICROCHIMICA ACTA, 2005, 149 (1-2) : 61 - 65
  • [34] Spectrophotometric determination of urinary iodine by flow injection analysis with on-line catalytic digestion
    Zhang, YP
    Yuan, DX
    Chen, JX
    Lan, TS
    Chen, HQ
    CLINICAL CHEMISTRY, 1996, 42 (12) : 2021 - 2027
  • [35] A sensitive spectrophotometric method for lead determination by flow injection analysis with on-line preconcentration
    Di Nezio, MS
    Palomeque, ME
    Band, BSF
    TALANTA, 2004, 63 (02) : 405 - 409
  • [36] Chromium speciation using sequential injection analysis and multivariate curve resolution
    Gomez, V.
    Larrechi, M. S.
    Callao, M. P.
    ANALYTICA CHIMICA ACTA, 2006, 571 (01) : 129 - 135
  • [37] Chemical speciation by sequential injection analysis: an overview
    van Staden, JF
    Stefan, RI
    TALANTA, 2004, 64 (05) : 1109 - 1113
  • [38] Sequential eluent injection technique as a new approach for the on-line enrichment and speciation of Cr(III) and Cr(VI) species on a single column with FAAS detection
    Chamjangali, M. Arab
    Goudarzi, N.
    Mirheidari, M.
    Bahramian, B.
    JOURNAL OF HAZARDOUS MATERIALS, 2011, 192 (02) : 813 - 821
  • [39] On-line automated analytical signal diagnosis in sequential injection analysis systems using artificial neural networks
    Ruisanchez, I
    Lozano, J
    Larrechi, MS
    Rius, FX
    Zupan, J
    ANALYTICA CHIMICA ACTA, 1997, 348 (1-3) : 113 - 127
  • [40] Sequential injection system for on-line analysis of total nitrogen with UV-mineralization
    Oms, MT
    Cerdà, A
    Cerdà, V
    TALANTA, 2003, 59 (02) : 319 - 326