Determination of agreement between laboratory instruments

被引:0
|
作者
Gray, TE [1 ]
Pratt, MC
Cusick, PK
机构
[1] Univ Illinois, Coll Vet Med, Urbana, IL 61801 USA
[2] Abbott Labs, Div Drug Safety Evaluat, Div Pharmaceut Prod, Abbott Pk, IL 60064 USA
[3] Abbott Labs, Dept Pathol, Abbott Pk, IL 60064 USA
来源
关键词
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The present study was conducted to illustrate the utility of Bland-Altman plots for use by our laboratory staff and other non-statisticians in assessing the agreement between values measured by using two different laboratory instruments. A high degree of agreement reflects acceptable interchangeability of equipment and minimal effect on clinical decision-making, We have summarized literature that suggests that the regression line and correlation coefficient used with regression analysis, although commonly employed, are not appropriate first choices for evaluating agreement. Using the ABL 500 Radiometer and i-STAT Portable Chemistry Analyzer, we evaluated pH, PCO2, and TCO2. Bland-Altman plots were simple to produce, were not mathematics-intensive, and provided an easily interpreted, graphical answer to the question of agreement between instruments. For purposes of clinical decision-making, the ABL and i-STAT machines were found to be in good agreement for the tests evaluated.
引用
收藏
页码:56 / 59
页数:4
相关论文
共 50 条
  • [21] Bone and Muscle Parameters of the Tibia: Agreement Between the XCT 2000 and XCT 3000 Instruments
    Burrows, Melonie
    Cooper, David M. L.
    Liu, Danmei
    McKay, Heather A.
    JOURNAL OF CLINICAL DENSITOMETRY, 2009, 12 (02) : 186 - 194
  • [22] Calibration Transfer, Part IV: Measuring the Agreement Between Instruments Following Calibration Transfer
    Workman, Jerome, Jr.
    Mark, Howard
    SPECTROSCOPY, 2013, 28 (10) : 24 - +
  • [23] IMPORTANCE OF ROUTINE COMPARISONS BETWEEN LUMINEX INSTRUMENTS WITHIN A SINGLE LABORATORY
    Muchhala, Mayuri
    Wilmoth-Hosey, Lisa
    Marcus-Freeman, Nalaja
    Gebel, Howard M.
    Bray, Robert A.
    HUMAN IMMUNOLOGY, 2015, 76 : 87 - 87
  • [24] THE INTERNATIONAL RUBBER AGREEMENT - AIMS, INSTRUMENTS AND FUNCTION
    STIEPEL, D
    GUMMI ASBEST KUNSTSTOFFE, 1982, 35 (11): : 615 - &
  • [26] Agreement between Graz Malnutrition Screening (GMS) with subjective nutritional assessment instruments in hospitalized patients
    Batista Lima, Emanuella Mardegani
    Almeida, Betullya Lucas
    Gomes, Hanna Barbosa
    Borges Bartochevis, Janine Alexandre
    Toniato, Tatiana Salgado
    Lazzarini, Thailiny Ricati
    Silva Pereira, Taisa Sabrina
    Guandalini, Valdete Regina
    NUTRICION HOSPITALARIA, 2018, 35 (05) : 1138 - 1144
  • [27] Agreement between core laboratory and study investigators for imaging scores in a thrombectomy trial
    Fahed, Robert
    Ben Maacha, Malek
    Ducroux, Celina
    Khoury, Naim
    Blanc, Raphael
    Piotin, Michel
    Lapergue, Bertrand
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2018, 10 (12) : E30
  • [28] Agreement between Clinical Assessment and Laboratory Diagnosis of Ringworm in Calves at Auction Markets
    Spergser, Joachim
    Neuhuber, Thiemo
    Haupt, Herfried
    Kaltenegger, Gerd
    Wittek, Thomas
    ANIMALS, 2024, 14 (03):
  • [29] Agreement between family report and laboratory results of amphetamine-induced death
    Ghajari, Hadis
    Mirtorabi, Davood
    Ghadirzadeh, Mohammad Raza
    Kangavari, Hajar Nazari
    Shahbazi, Fatemeh
    Nazari, Seyed Saeed Hashemi
    TOXICOLOGIE ANALYTIQUE ET CLINIQUE, 2021, 33 (01) : 74 - 81
  • [30] An economical cover for laboratory instruments
    McClellan, RH
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1933, 101 : 1481 - 1482