Determination of agreement between laboratory instruments

被引:0
|
作者
Gray, TE [1 ]
Pratt, MC
Cusick, PK
机构
[1] Univ Illinois, Coll Vet Med, Urbana, IL 61801 USA
[2] Abbott Labs, Div Drug Safety Evaluat, Div Pharmaceut Prod, Abbott Pk, IL 60064 USA
[3] Abbott Labs, Dept Pathol, Abbott Pk, IL 60064 USA
来源
关键词
D O I
暂无
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The present study was conducted to illustrate the utility of Bland-Altman plots for use by our laboratory staff and other non-statisticians in assessing the agreement between values measured by using two different laboratory instruments. A high degree of agreement reflects acceptable interchangeability of equipment and minimal effect on clinical decision-making, We have summarized literature that suggests that the regression line and correlation coefficient used with regression analysis, although commonly employed, are not appropriate first choices for evaluating agreement. Using the ABL 500 Radiometer and i-STAT Portable Chemistry Analyzer, we evaluated pH, PCO2, and TCO2. Bland-Altman plots were simple to produce, were not mathematics-intensive, and provided an easily interpreted, graphical answer to the question of agreement between instruments. For purposes of clinical decision-making, the ABL and i-STAT machines were found to be in good agreement for the tests evaluated.
引用
收藏
页码:56 / 59
页数:4
相关论文
共 50 条
  • [1] Assessment of the agreement between three haematology instruments
    Ennouchi, F
    Martin, SA
    Chanteperdrix, V
    Buisson, NR
    Polack, B
    Mossuz, P
    ANNALES DE BIOLOGIE CLINIQUE, 2002, 60 (03) : 351 - 355
  • [2] Instruments and experiments between the laboratory and the museum
    Heering, Peter
    Sichau, Christian
    ARCHIVES DES SCIENCES, 2005, 58 (02): : 97 - 111
  • [3] COMMUNICATION BETWEEN THE PC AND LABORATORY INSTRUMENTS
    PETRINI, MF
    DWYER, TM
    WALL, MA
    MANSEL, JK
    NORMAN, JR
    COMPUTER APPLICATIONS IN THE BIOSCIENCES, 1990, 6 (03): : 161 - 164
  • [4] Agreement between health utility instruments in cochlear implantation
    Ramakers, G. G. J.
    Smulders, Y. E.
    van Zon, A.
    Kraaijenga, V. J. C.
    Stegeman, I.
    Van Zanten, G. A.
    Grolman, W.
    CLINICAL OTOLARYNGOLOGY, 2016, 41 (06) : 737 - 743
  • [5] Fiducial approach for assessing agreement between two instruments
    Wang, C. M.
    Iyer, Hari K.
    METROLOGIA, 2008, 45 (04) : 415 - 421
  • [6] Agreement between instruments for rating treatment decisional capacity
    Gurrera, Ronald J.
    Karel, Michele J.
    Azar, Armin R.
    Moye, Jennifer
    AMERICAN JOURNAL OF GERIATRIC PSYCHIATRY, 2007, 15 (02): : 168 - 173
  • [7] Statistical techniques for assessing the agreement between two instruments
    Astrua, M.
    Ichim, D.
    Pennecchi, F.
    Pisani, M.
    METROLOGIA, 2007, 44 (05) : 385 - 392
  • [8] Agreement of Fixation Disparity Curve between Two Different Instruments
    Hashemi, Hassan
    Mirzaeian, Maryam
    Narooie, Foroozan
    Nabovati, Payam
    Yekta, Abbasali
    Ostadimoghaddam, Hadi
    Sardari, Sara
    Khabazkhoob, Mehdi
    OPTOMETRY AND VISION SCIENCE, 2021, 98 (06) : 629 - 635
  • [9] Describing the within laboratory and between laboratory agreement of a serum ELISA in a national laboratory network
    Jordan, David
    Kirkland, Peter
    Morris, Stephen
    Coilparampil, Ronald
    PREVENTIVE VETERINARY MEDICINE, 2012, 104 (3-4) : 240 - 248
  • [10] On the determination of the emission wavelength of an infrared LED with common laboratory instruments
    RayChaudhuri, Barun
    EUROPEAN JOURNAL OF PHYSICS, 2011, 32 (04) : 935 - 945