Highly Sensitive and Selective Detection of Dopamine at Poly (chromotrope 2B)-Modified Glassy Carbon Electrode in the Presence of Uric Acid and Ascorbic Acid

被引:63
|
作者
Li, Xiao-Bo [1 ,2 ,3 ]
Rahman, Md Mahbubur [2 ,3 ]
Xu, Guang-Ri [1 ]
Lee, Jae-Joon [2 ,3 ]
机构
[1] Henan Inst Sci & Technol, Dept Chem & Chem Engn, Xinxiang 453003, Peoples R China
[2] Konkuk Univ, Coll Biomed & Hlth Sci, Nanotechnol Res Ctr, Chungju 380701, South Korea
[3] Konkuk Univ, Coll Biomed & Hlth Sci, Dept Appl Life Sci, Chungju 380701, South Korea
基金
新加坡国家研究基金会;
关键词
Poly(chromotrope 2B); Dopamine; Ascorbic acid; Uric acid; Electrostatic interaction; PASTE ELECTRODE; ELECTROCHEMICAL DETERMINATION; BEHAVIOR; SURFACE; FILM; ACTIVATION; MICELLES; SDS;
D O I
10.1016/j.electacta.2015.05.062
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A highly sensitive and selective electrochemical method based on a poly(chromotrope 2B)-modified anodized glassy carbon electrode (PCHAGCE) was developed for the determination of dopamine (DA) in the presence of uric acid (UA) and ascorbic acid (AA). The PCHAGCE sensor exhibited excellent electron-mediating behavior towards the oxidation of DA in 0.1 M phosphate buffer solution (PBS) (pH 7.0). It was found that the electrocatalytic activity was significantly dependent on the charge status and molecular structure of the target molecules. Differential pulse voltammetry (DPV) measurements revealed oxidation signals for DA, UA, and AA that were well-resolved into three distinct peaks with AA-DA, DA-UA, and AA-UA peak potential separations (Delta E-p) of 172,132, and 304 mV, respectively. A detection limit of 0.04 +/- 0.001 mu M (S/N = 3) and a quantification limit (S/N = 10) of 0.149 +/- 0.03 mu M were obtained for DA sensing in a linear range of 1 to 40 mu M in PBS (pH 7.0) with a very high sensitivity of 1.522 +/- 0.032 mu A.mu M-1. The DA concentrations in human urine samples were also successfully determined with recoveries of 94.0-98.0%. This approach provides a simple, easy, sensitive, and selective method to detect DA in the presence of AA and UA. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:440 / 447
页数:8
相关论文
共 50 条
  • [41] Simultaneous determination of ascorbic acid, dopamine and uric acid using poly(4-aminobutyric acid) modified glassy carbon electrode
    Zheng, Xinyu
    Zhou, Xuechou
    Ji, Xiaoyan
    Lin, Ruiyu
    Lin, Wenxiong
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 178 : 359 - 365
  • [42] A novel poly(4-aminopyridine) modified electrode for selective detection of uric acid in the presence of ascorbic acid
    Wang, ZH
    Zhang, D
    Zhang, Y
    Zhou, SP
    ANALYTICAL LETTERS, 2002, 35 (09) : 1453 - 1464
  • [43] Highly selective determination of uric acid in the presence of ascorbic acid at glassy carbon electrodes modified with carbon nanotubes dispersed in polylysine
    Rodriguez, Marcela C.
    Sandoval, Jose
    Galicia, Laura
    Gutierrez, Silvia
    Rivas, Gustavo A.
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) : 559 - 565
  • [44] Simultaneous Determination of Dopamine and Uric Acid in the Presence of Ascorbic Acid at the Indole-3-Carboxaldehyde Modified Glassy Carbon Electrode
    Deletioglu, Didem
    Hasdemir, Erdogan
    Solak, Ali O.
    CURRENT ANALYTICAL CHEMISTRY, 2010, 6 (03) : 203 - 208
  • [45] Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode
    Sun, D. M.
    Hu, W. N.
    Ma, W.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (03) : 310 - 316
  • [46] Simultaneous electrochemical detection of uric acid and ascorbic acid at a silver doped poly(glutamic acid) modified glassy carbon electrode
    D. M. Sun
    W. N. Hu
    W. Ma
    Journal of Analytical Chemistry, 2011, 66 : 310 - 316
  • [47] Determination of dopamine in the presence of ascorbic acid using poly (acridine red) modified glassy carbon electrode
    Zhang, YZ
    Jin, GY
    Wang, YL
    Yang, ZS
    SENSORS, 2003, 3 (10): : 443 - 450
  • [48] Determination of dopamine in presence of ascorbic acid and uric acid using poly (Spands Reagent) modified carbon paste electrode
    Reddy, Y. Veera Manohara
    Rao, V. Prabhakara
    Reddy, A. Vijaya Bhaskar
    Lavanya, M.
    Venu, M.
    Lavanya, M.
    Madhavi, G.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 57 : 378 - 386
  • [49] Highly selective detection of dopamine in the presence of ascorbic-acid and uric acid using thioglycolic acid capped CdTe quantum dots modified electrode
    Roushani, Mahmoud
    Shamsipur, Mojtaba
    Rajabi, Hamid Reza
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 712 : 19 - 24
  • [50] Carbon nanotubes/alizarin red S–poly(vinylferrocene) modified glassy carbon electrode for selective determination of dopamine in the presence of ascorbic acid
    Mine Şen
    Uğur Tamer
    Nuran Özçiçek Pekmez
    Journal of Solid State Electrochemistry, 2012, 16 : 457 - 463