Free-Breathing 3D T1-Weighted Gradient-Echo Sequence With Radial Data Sampling in Abdominal MRI: Preliminary Observations

被引:69
|
作者
Azevedo, Rafael M. [1 ]
de Campos, Rafael O. P. [1 ]
Ramalho, Miguel [1 ]
Heredia, Vasco [1 ]
Dale, Brian M. [2 ]
Semelka, Richard C. [1 ]
机构
[1] Univ N Carolina, Dept Radiol, Chapel Hill, NC 27599 USA
[2] Siemens Healthcare, Cary, NC USA
关键词
3D gradient-echo sequence; abdominal MRI; free breathing; radial acquisition; uncooperative patient; K-SPACE; HEPATOCELLULAR-CARCINOMA; LIVER; RECONSTRUCTION; ABDOMEN;
D O I
10.2214/AJR.10.5881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purposes of this study were to evaluate the feasibility of a free-breathing 3D gradient-recalled echo sequence with radial data sampling (radial 3D GRE) in abdominal MRI compared with a standard 3D GRE volumetric interpolated breath-hold examination (VIBE) sequence for imaging of cooperative patients and to perform a preliminary assessment in imaging of noncooperative patients. MATERIALS AND METHODS. Fifty-five consecutively registered patients who underwent unenhanced and contrast-enhanced abdominal MRI with the free-breathing radial 3D GRE technique constituted the study population. Two readers independently and blindly evaluated the images. RESULTS. Overall image quality with the contrast-enhanced radial 3D GRE sequence was lower than but rated at least nearly as good as that with the 3D GRE VIBE sequence (p < 0.0001). Higher scores were recorded for 3D GRE VIBE images with respect to pixel graininess, streaking artifact, and sharpness (p = 0.0009 to p < 0.0001). Except for sharpness of vessels on unenhanced images, results for the radial 3D GRE sequence did not differ significantly in the comparison of cooperative and noncooperative patients (p = 0.004). For imaging of noncooperative patients, radial 3D GRE images of children had higher ratings for shading (unenhanced, p = 0.0004; contrast-enhanced, p < 0.0001) and streaking artifacts on contrast-enhanced images (p = 0.0017) than did those of adults. Overall image quality was higher for pediatric patients. In lesion analysis, use of the 3D GRE VIBE sequence was associated with significantly greater detectability, confidence, and conspicuity than was use of the radial 3D GRE sequence (p = 0.00026-0.011). CONCLUSION. A free-breathing radial 3D GRE sequence is feasible for abdominal MRI and may find application in imaging of patients who are unable to suspend respiration, especially children.
引用
收藏
页码:650 / 657
页数:8
相关论文
共 50 条
  • [31] Free-breathing 3D CEST MRI of human liver at 3.0 T
    Han, Pei
    Cheema, Karandeep
    Cao, Tianle
    Lee, Hsu-Lei
    Han, Fei
    Wang, Nan
    Han, Hui
    Xie, Yibin
    Christodoulou, Anthony G.
    Li, Debiao
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (02) : 738 - 745
  • [32] A comparison of a T1 weighted 3D gradient-echo sequence with three different parallel imaging reduction factors, breath hold and free breathing, using a32 channel coil at 1.5T. A preliminary study
    Heredia, V.
    Dale, B.
    de Campos, R. Op
    Ramalho, M.
    Burke, L. B.
    Sams, C.
    de Toni, M.
    Semelka, R. C.
    RADIOLOGIA, 2014, 56 (06): : 533 - 540
  • [34] Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC)
    Kim, Kyung Won
    Lee, Jeong Min
    Jeon, Yong Sik
    Kang, Sung Eun
    Baek, Jee Hyun
    Han, Joon Koo
    Choi, Byung Ihn
    Bang, Yung-Jue
    Kiefer, Berthold
    Block, Kai Tobias
    Ji, Hyunjun
    Bauer, Simon
    Kim, Chin
    EUROPEAN RADIOLOGY, 2013, 23 (05) : 1352 - 1360
  • [35] Free-breathing dynamic contrast-enhanced MRI of the abdomen and chest using a radial gradient echo sequence with K-space weighted image contrast (KWIC)
    Kyung Won Kim
    Jeong Min Lee
    Yong Sik Jeon
    Sung Eun Kang
    Jee Hyun Baek
    Joon Koo Han
    Byung Ihn Choi
    Yung-Jue Bang
    Berthold Kiefer
    Kai Tobias Block
    Hyunjun Ji
    Simon Bauer
    Chin Kim
    European Radiology, 2013, 23 : 1352 - 1360
  • [36] Hybrid 3D T1-weighted gradient-echo sequence for fiducial marker detection and tumor delineation via magnetic resonance imaging in liver stereotactic body radiation therapy
    Kato, Yutaka
    Kamomae, Takeshi
    Kumagai, Motoki
    Oie, Yumi
    Noguchi, Yumiko
    Okudaira, Kuniyasu
    Kawamura, Mariko
    Taoka, Toshiaki
    Naganawa, Shinji
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 95 : 9 - 15
  • [37] Inflow correction of hepatic perfusion measurements using T1-weighted, fast gradient-echo, contrast-enhanced MRI
    Peeters, F
    Annet, L
    Hermoye, L
    Van Beers, BE
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (04) : 710 - 717
  • [38] Free-breathing 3D steady-state free precession coronary MR angiography with radial k-space sampling:: Comparison with cartesian k-space sampling and cartesian gradient-echo coronary MR angiography -: Pilot study
    Spuentrup, E
    Katoh, M
    Buecker, A
    Manning, WJ
    Schaeffter, T
    Nguyen, TH
    Kühl, HP
    Stuber, M
    Botnar, RM
    Günther, RW
    RADIOLOGY, 2004, 231 (02) : 581 - 586
  • [39] MRI IMAGING OF THE LIVER AT 1,5 TESLA - VALUE OF T1-WEIGHTED IMAGING WITH A FAST MULTISLICE GRADIENT-ECHO SEQUENCE DURING BREATH-HOLDING
    TAUPITZ, M
    HAMM, B
    SPEIDEL, A
    BRANDING, G
    WOLF, KJ
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1991, 155 (02): : 135 - 141
  • [40] Ovarian Masses: MR Imaging with T1-weighted 3-dimensional Gradient-echo IDEAL Water-fat Separation Sequence at 3T
    Hori, Masatoshi
    Kim, Tonsok
    Onishi, Hiromitsu
    Nakamoto, Atsushi
    Tsuboyama, Takahiro
    Tatsumi, Mitsuaki
    Tomiyama, Noriyuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2012, 11 (02) : 117 - 127