Ion-selective electrodes:: Polyaniline modification and anion recognition

被引:53
|
作者
Shishkanova, TV
Sapurina, I
Stejskal, J
Král, V
Volf, R
机构
[1] Inst Chem Technol, Dept Analyt Chem, CR-16628 Prague, Czech Republic
[2] Russian Acad Sci, Inst Macromol Cpds, St Petersburg 199004, Russia
[3] Acad Sci Czech Republ, Inst Macromol Chem, CR-16206 Prague, Czech Republic
关键词
ion-selective electrode; surface modification; polyaniline; anion recognition; conducting polymer;
D O I
10.1016/j.aca.2005.08.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel arrangement for polymeric membranes used in ion-selective electrodes is presented. The surface of a conventional plasticized poly(vinyl chloride) (PVC) membrane was coated with a chemically generated film of a conducting polymer, polyaniline (PANI). The effect of PANI on the anionic potentiometric response of PVC membranes derived from calix[4]pyrrole and tridodecylmethylammonium chloride (TDDMACI) is reported. Five different types of electrodes with the following membrane compositions were studied: (1) PVC/PANI (a reference experiment), (2) PVC + TDDMACI (as anion-exchanger)/PANI, (3) PVC + calix[4]pyrrole (as neutral carrier)/PANI, (4) PVC + calix[4]pyrrole + TDDMACI (uncoated membrane) and (5) PVC + calix[4]pyrrole + TDDMACl/PANI. Hydrophilicity of the uncoated and PANI-coated membrane surfaces was assessed by measurements of water contact angle, theta. In the protonated state, the neat PANI is more hydrophilic, theta = 49 degrees, than in its deprotonated base form, theta = 94 degrees. After surface deposition of thin PANI film, increased potentiometric sensitivity of the membranes, especially towards hydrophilic anions (F-, H2PO4-), was achieved. The distinct differences in the character of calix[4]pyrrole (neutral carrier) and TDDMACI (anion-exchanger) to sense anionic species were retained and became more pronounced. The PANI film may be regarded as a novel kind of an electrode modifier for anion-sensing. The role of the PANI film in the formation of the potentiometric response is discussed. It is proposed that the PANI film acts as an anion-exchanger. The transport of anions through a thin PANI film is also affected by the character of anions and by pH.
引用
收藏
页码:160 / 168
页数:9
相关论文
共 50 条
  • [21] ION-SELECTIVE ELECTRODES
    BUCK, RP
    ANALYTICAL CHEMISTRY, 1976, 48 (05) : R23 - R39
  • [22] ION-SELECTIVE ELECTRODES
    PUNGOR, E
    TOTH, K
    NAGY, G
    MIKROCHIMICA ACTA, 1978, 1 (5-6) : 531 - 545
  • [23] ION-SELECTIVE ELECTRODES
    FRICKE, GH
    ANALYTICAL CHEMISTRY, 1980, 52 (05) : R259 - R275
  • [24] ION-SELECTIVE ELECTRODES
    FISCHER, RB
    JOURNAL OF CHEMICAL EDUCATION, 1974, 51 (06) : 387 - 390
  • [25] Ion-selective electrodes
    James, TJ
    POSTGRADUATE MEDICAL JOURNAL, 1999, 75 (882) : 254 - 254
  • [26] ION-SELECTIVE ELECTRODES
    SOLSKY, RL
    ANALYTICAL CHEMISTRY, 1988, 60 (12) : R106 - R113
  • [27] Nonequilibrium Anion Detection in Solid-Contact Ion-Selective Electrodes
    Gettler, Ryan C.
    Mehregan, Shima
    Koenig, Henry D.
    Kaess, Andie M.
    Young, Matthias J.
    ACS OMEGA, 2024, 9 (14): : 16443 - 16457
  • [28] Anion Selectivities of Dibutyltin Dihalides as Neutral Carriers for Ion-Selective Electrodes
    Takayo Moriuchi-Kawakami
    Hiroshi Aoto
    Naotake Takeda
    Keiichi Fujimori
    Yasuhiko Shibutani
    Analytical Sciences, 2000, 16 : 303 - 306
  • [29] Anion selectivities of dibutyltin dihalides as neutral carriers for ion-selective electrodes
    Moriuchi-Kawakami, T
    Aoto, H
    Takeda, N
    Fujimori, K
    Shibutani, Y
    ANALYTICAL SCIENCES, 2000, 16 (03) : 303 - 306
  • [30] Ion-selective electrodes and ion optodes
    Widmer, H.Michael
    Analytical methods & instrumentation, 1993, 1 (01): : 60 - 72