Laboratory Calibration, In-Field Validation and Use of a Soil Penetrometer Measuring Cone Resistance and Water Content

被引:0
|
作者
Topp, G. C. [1 ]
Lapen, D. R. [1 ]
Edwards, M. J. [1 ]
Young, G. D. [2 ]
机构
[1] Agr & Agri Food Canada, Eastern Cereal & Oilseed Res Ctr, Ottawa, ON K1A 0C6, Canada
[2] ESI, Victoria, BC V8Z 4B9, Canada
来源
VADOSE ZONE JOURNAL | 2003年 / 2卷 / 04期
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Concurrent and coincident measure of penetrometer cone resistance (PR) and water content (WC) were optimized by hourly infield validation of data from time domain transmissiometry (TDT) for WC and piezoelectric force sensor for PR. A piezoelectric force sensor coupled to a cone is followed by a helical wrapped TDT sensor on a single penetrometer shaft. Detailed laboratory calibrations, coupled with in-field validations, were important to assure the quality of data, which facilitated detailed analyses of PR and WC patterns. The piezoelectric sensor relied on a calibrated spring for the in-field validation. The calibration of the TDT sensor had three stages: a series of fluids of known dielectric constant; soil columns at known, variable water contents; and field soils at a range of ambient conditions. The penetrometer was used to study soil strength and WC behavior in time and space along 300-m plots. The treatments were conventional and no-till, each at two levels of traffic. The crop was corn (Zea mays L.), continuous and in rotation with soybean [Glycine max (L.) Merr.] and wheat (Triticum aestivum L.). The PR vs. WC relationships for two depths (0.21 and 0.27 m), below the level of cultivation, were similar to those at the 0.10-m depth for the nontrafficked no-till plots. These relationships for the 0.21 and 0.27-m depths were not influenced by tillage, traffic, and corn cropping system treatments. The variable depth of plowing in tilled plots was found to influence the data consistency for the 0.21-m depth, indicating the penetrometer's high sensitivity to the soil conditions.
引用
收藏
页码:633 / 641
页数:9
相关论文
共 50 条
  • [11] Calibration of a capacitance system for measuring water content of tropical soil
    Polyakov, V
    Fares, A
    Ryder, MH
    VADOSE ZONE JOURNAL, 2005, 4 (04) : 1004 - 1010
  • [12] Field and laboratory calibration and test of TDR and capacitance techniques for indirect measurement of soil water content
    Lane, PNJ
    Mackenzie, DH
    AUSTRALIAN JOURNAL OF SOIL RESEARCH, 2001, 39 (06): : 1371 - 1386
  • [13] Erratum to: In-field Assessment of Soil Salinity and Water Content with Electrical Geophysics
    L. A. Pozdnyakova
    A. Yu. Trubin
    S. Orunbaev
    Yu. A. Manstein
    A. B. Umarova
    Moscow University Soil Science Bulletin, 2024, 79 (2) : 214 - 214
  • [14] In-field calibration of a dielectric soil moisture meter designed for use in an access tube
    Whalley, WR
    Cope, RE
    Nicholl, CJ
    Whitmore, AP
    SOIL USE AND MANAGEMENT, 2004, 20 (02) : 203 - 206
  • [15] On-the-go measurement of soil water content and mechanical resistance by a combined horizontal penetrometer
    Sun, Y
    Ma, D
    Lammers, PS
    Schmittmann, O
    Rose, A
    SOIL & TILLAGE RESEARCH, 2006, 86 (02): : 209 - 217
  • [16] A portable data collection system for simultaneous cone penetrometer force and volumetric soil water content measurements
    Young, GD
    Adams, BA
    Topp, GC
    CANADIAN JOURNAL OF SOIL SCIENCE, 2000, 80 (01) : 23 - 31
  • [17] A novel approach to estimate soil penetrometer resistance from water content, bulk density, and shear wave velocity: A laboratory study on a loamy sand soil
    Zhang, Wencan
    Gao, Weida
    Ren, Tusheng
    Whalley, W. Richard
    GEODERMA, 2020, 368
  • [18] FIELD CALIBRATION AND MONITORING OF SOIL-WATER CONTENT WITH FIBERGLASS ELECTRICAL-RESISTANCE SENSORS
    SEYFRIED, MS
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 1993, 57 (06) : 1432 - 1436
  • [19] Monitoring soil water content profiles with a commercial TDR system:: Comparative field tests and laboratory calibration
    Laurent, JP
    Ruelle, P
    Delage, L
    Zaïri, A
    Ben Nouna, B
    Adjmi, T
    VADOSE ZONE JOURNAL, 2005, 4 (04) : 1030 - 1036
  • [20] Validation of In-field Calibration for Low-Cost Sensors Measuring Ambient Particulate Matter in Kolkata, India
    Nobell, Siddharth
    Majumdar, Arnab
    Mukherjee, Shovon
    Chakraborty, Sukumar
    Chatterjee, Sanjoy
    Bose, Soumitra
    Dutta, Anindita
    Sethuraman, Sandhya
    Westervelt, Daniel M.
    Sengupta, Shairik
    Basu, Rakhi
    McNeill, V. Faye
    AEROSOL AND AIR QUALITY RESEARCH, 2023, 23 (11)