Quantitative assessment of articular cartilage degeneration using 3D ultrashort echo time cones adiabatic T1ρ (3D UTE-Cones-AdiabT1ρ) imaging

被引:5
|
作者
Wu, Mei [1 ,2 ]
Ma, Ya-Jun [2 ]
Liu, Mouyuan [3 ]
Xue, Yanping [2 ]
Gong, Lillian [2 ]
Wei, Zhao [2 ]
Jerban, Saeed [2 ]
Jang, Hyungseok [2 ]
Chang, Douglas G. [4 ]
Chang, Eric Y. [2 ,5 ]
Ma, Liheng [3 ]
Du, Jiang [2 ]
机构
[1] South China Univ Technol, Sch Med, Guangzhou Peoples Hosp 1, Dept Radiol, Guangzhou, Guangdong, Peoples R China
[2] Univ Calif San Diego, Dept Radiol, 9452 Med Ctr Dr, San Diego, CA 92037 USA
[3] Guangdong Pharmaceut Univ, Affiliated Hosp 1, Imaging Dept, Guangzhou, Guangdong, Peoples R China
[4] Univ Calif San Diego, Dept Orthopaed Surg, San Diego, CA 92103 USA
[5] Vet Affairs San Diego Healthcare Syst, Radiol Serv, San Diego, CA USA
关键词
Ultrashort echo time; AdiabT(1 rho); Articular cartilage; Degeneration; Quantitative assessment; ROTATING-FRAME RELAXATION; OSTEOARTHRITIS; KNEE; MRI; VALIDATION; T-2-RHO; T-2;
D O I
10.1007/s00330-022-08722-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate articular cartilage degeneration using quantitative three-dimensional ultrashort-echo-time cones adiabatic-T-1 rho (3D UTE-Cones-AdiabT(1 rho)) imaging. Methods Sixty-six human subjects were recruited for this study. Kellgren-Lawrence (KL) grade and Whole-Organ MagneticResonance-Imaging Score (WORMS) were evaluated by two musculoskeletal radiologists. The human subjects were categorized into three groups, namely normal controls (KL0), doubtful-minimal osteoarthiitis (OA) (KL1-2), and moderate-severe OA (KL3-4). WORMS were regrouped to encompass the extent of lesions and the depth of lesions. The UTE-Cones-AdiabT(1 rho) values were obtained using 3D UTE-Cones data acquisitions preceded by seven paired adiabatic full passage pulses that corresponded to seven spin-locking times (TSLs) of 0, 12, 24, 36, 48, 72, and 96 ms. The performance of the UTE-Cones-AdiabT(1 rho) technique in evaluating the degeneration of knee cartilage was assessed via the ANOVA comparisons with subregional analysis and Spearman's correlation coefficient as well as the receiver-operating-characteristic (ROC) curve. Results UTE-Cones-AdiabT(1 rho) showed significant positive correlations with KL grade (r = 0.15, p < 0.05) and WORMS (r = 0.57, p < 0.05). Higher UTE-Cones-AdiabT(1 rho) values were observed in both larger and deeper lesions in the cartilage. The differences in UTE-Cones-AdiabT(1 rho) values among different extent and depth groups of cartilage lesions were all statistically significant (p < 0.05). Subregional analyses showed that the correlations between UTE-Cones-AdiabT(1 rho) and WORMS varied with the location of cartilage. The AUC value of UTE-Cones-AdiabT(1 rho) for mild cartilage degeneration (WORMS=1) was 0.8. The diagnostic threshold value of UTE-Cones-AdiabT(1 rho) for mild cartilage degeneration was 39.4 ms with 80.8% sensitivity. Conclusions The 3D UTE-Cones-AdiabT(1 rho) sequence can be useful in quantitative evaluation of articular cartilage degeneration.
引用
收藏
页码:6178 / 6186
页数:9
相关论文
共 50 条
  • [41] Fast T1 measurement of cortical bone using 3D UTE actual flip angle imaging and single-TR acquisition (3D UTE-AFI-STR)
    Wei, Zhao
    Jang, Hyungseok
    Bydder, Graeme M.
    Yang, Wenhui
    Ma, Ya-Jun
    MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (06) : 3290 - 3298
  • [42] Validation and Optimization of Adiabatic T1ρ and T2ρ for Quantitative Imaging of Articular Cartilage at 3T
    Casula, Victor
    Autio, Joonas
    Nissi, Mikko J.
    Auerbach, Edward J.
    Ellermann, Jutta
    Lammentausta, Eveliina
    Nieminen, Miika T.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (03) : 1265 - 1275
  • [43] Volumetric mapping of bound and pore water as well as collagen protons in cortical bone using 3D ultrashort echo time cones MR imaging techniques
    Jerban, Saeed
    Ma, Yajun
    Li, Liang
    Jang, Hyungseok
    Wan, Lidi
    Guo, Tan
    Searleman, Adam
    Chang, Eric Y.
    Du, Jiang
    BONE, 2019, 127 : 120 - 128
  • [44] Assessment of Anterior Cruciate Ligament Reconstruction Using 3D Ultrashort Echo-Time MR Imaging
    Rahmer, Juergen
    Boernert, Peter
    Dries, Sebastian P. M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) : 443 - 448
  • [45] Improved Lesion Conspicuity with Contrast-Enhanced 3D T1 TSE Black-Blood Imaging in Cranial Neuritis: A Comparative Study of Contrast-Enhanced 3D T1 TSE, 3D T1 Fast-Spoiled Gradient Echo, and 3D T2 FLAIR
    Baek, T. W.
    Kang, Y.
    Lee, H. -J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (05) : 945 - 950
  • [46] 3D magnetic resonance fingerprinting for rapid simultaneous T1, T2, and T1ρ volumetric mapping of human articular cartilage at 3 T
    Sharafi, Azadeh
    Zibetti, Marcelo V. W.
    Chang, Gregory
    Cloos, Martijn
    Regatte, Ravinder R.
    NMR IN BIOMEDICINE, 2022, 35 (12)
  • [47] 3D thickness maps of articular cartilage for quantitative assessment of osteoarthritis.
    Steines, D
    Berger, F
    Cheng, C
    Napel, S
    Lang, P
    ARTHRITIS AND RHEUMATISM, 2000, 43 (09): : S353 - S353
  • [48] Editorial for "Assessment of Pulmonary Ventilation Using 3D Ventilation Flow-Weighted and Ventilation-Weighted Maps From 3D Ultrashort Echo-Time (UTE) MRI"
    Higano, Nara S.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (02) : 495 - 496
  • [49] RAPID 3D PRECLINICAL QUANTITATIVE LUNG IMAGING WITH ULTRASHORT-ECHO TIME (UTE) MRI IN A MOUSE MODEL OF CYSTIC FIBROSIS LUNG DISEASE
    Anderson, C.
    Flask, C.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2016, 64 (04) : 975 - 975
  • [50] Whole-Brain Myelin Imaging Using 3D Double-Echo Sliding Inversion Recovery Ultrashort Echo Time (DESIRE UTE) MRI
    Ma, Ya-Jun
    Searleman, Adam C.
    Jang, Hyungseok
    Wong, Jonathan
    Chang, Eric Y.
    Corey-Bloom, Jody
    Bydder, Graeme M.
    Du, Jiang
    RADIOLOGY, 2020, 294 (02) : 362 - 374