Linear peristaltic pump driven by three magnetic actuators: simulation and experimental results

被引:0
|
作者
Barreto Neto, A. G. S. [1 ,2 ,4 ]
Lima, A. M. N. [1 ,2 ]
Neff, H. [1 ,2 ,3 ]
Gomes, Caio Luiz [1 ,2 ]
Moreira, Cleumar [5 ]
机构
[1] Univ Fed Campina Grande, CEEI, DEE, Rua Aprigio Veloso 882, BR-58429900 Campina Grande, Paraiba, Brazil
[2] Bairro Univ, BR-58429900 Campina Grande, Paraiba, Brazil
[3] Cidade Univ, Ctr Strateg Res CETENE, LINCS, BR-50740540 Recife, PE, Brazil
[4] Inst Fed Paraiba IFPB, Dept Electromech, Cajazeiras, Paraiba, Brazil
[5] Inst Fed Alagoas IFAL, Dept Elect, Maceio, Alagoas, Brazil
来源
2011 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC) | 2011年
关键词
Linear Peristaltic Pump; Driving Sequence; Finite Elements-based Simulation; Fluid Structure Interaction; MICROPUMP; MINIATURE;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A bi-directional linear peristaltic pump is presented that avoids use of a rotating step motor and rollers. Fluid displacement, flow and pump function, respectively, are achieved by means of three electro-magnetic actuators. They are electronically controlled and designed to periodically squeeze an elastic tube that contains the liquid. The device reveals a very simple construction, is maintenance free, has very low power consumption, thus accounting for very low manufacture and operation costs. Upon reducing the size of the actuators, it can be easily integrated with micro fluidic arrangements. Flow and pressure pulsation can be reduced by increasing the number of actuators. A finite element-based numerical model has been developed, using the fluid structure interaction (FSI) model. The flow dynamics inside the tube has been treated, using the coupling between the Navier-Stokes and the elastic displacement equations of the elastic tube. The appropriate and optimum timely driving sequence of the actuators, as well as the response characteristics of the physical system, were also numerically evaluated. Experimental results fully agree with the numerical simulation results. The dynamic range of the flow rate was determined as ranging from 700 mu/min to 79ml/min, while the back pressure varies between 400 mmHg to 14 mmHg.
引用
收藏
页码:1454 / 1459
页数:6
相关论文
共 50 条
  • [41] Experimental and Simulation Results of Magnetic Modulation of Gate Oxide Tunneling Current in Nanoscaled MOS Transistors
    Rodriguez-Ruiz, Gabriela A.
    Gutierrez-Dominguez, Edmundo A.
    Sarmiento-Reyes, Arturo
    Stanojevic, Zlatan
    Kosina, Hans
    Guarin, Fernando J.
    Garcia-Ramirez, Pedro J.
    IEEE ELECTRON DEVICE LETTERS, 2015, 36 (04) : 387 - 389
  • [42] SHIELDING THE MAGNETIC FIELD FROM A TRANSCRANIAL STIMULATOR USING ALUMINIUM AND IRON: SIMULATION AND EXPERIMENTAL RESULTS
    Saraiva Santos, Nuno
    Sousa, Sonia C. P.
    Crespo, Paulo
    Cavaleiro Miranda, Pedro
    Salvador, Ricardo
    Silvestre, Joao
    2015 IEEE 4TH PORTUGUESE MEETING ON BIOENGINEERING (ENBENG), 2015,
  • [43] Three-dimensional numerical simulation and experimental validation of flows in working chambers and inlet/outlet pockets of Roots pump
    Sun, Shu-Kai
    Zhao, Bin
    Jia, Xiao-Han
    Peng, Xue-Yuan
    VACUUM, 2017, 137 : 195 - 204
  • [44] Transient modeling of a flash tank vapor injection heat pump system - Part II: Simulation results and experimental validation
    Qiao, Hongtao
    Xu, Xing
    Aute, Vikrant
    Radermacher, Reinhard
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 49 : 183 - 194
  • [45] Validation of an IDDES-type turbulence model and application to a Francis pump turbine flow simulation in comparison with experimental results
    Krappel, T.
    Kuhlmann, H.
    Kirschner, O.
    Ruprecht, A.
    Riedelbauch, S.
    INTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, 2015, 55 : 167 - 179
  • [46] Parameters and forces of a PM linear synchronous motor with magnetic guides for industrial applications: Computed and experimental results
    Profumo, F
    Tenconi, A
    Gianolio, G
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 15 - 20
  • [47] Fitness analysis of experimental results and finite element simulation results about bullet velocity based on ABAQUS simulation for impact of three dimensional woven reinforced composite
    Qian, Fei
    Zhao, Lei
    Wei, Li
    Zhang, Shengzhong
    Yao, Guixiang
    Liu, Yuankun
    JOURNAL OF ENGINEERED FIBERS AND FABRICS, 2022, 17
  • [48] Three-dimensional Hybrid Simulation Results of a Variable Magnetic Helicity Signature at Proton Kinetic Scales
    Vasquez, Bernard J.
    Markovskii, Sergei A.
    Smith, Charles W.
    ASTROPHYSICAL JOURNAL, 2022, 924 (02):
  • [49] Three-dimensional numerical simulation of thermal convection in an industrial Czochralski melt:: comparison to experimental results
    Vizman, D
    Gräbner, O
    Müller, G
    JOURNAL OF CRYSTAL GROWTH, 2001, 233 (04) : 687 - 698
  • [50] Fault detection on a real three-phase induction motor: Simulation and experimental results on residual generation
    Contin, A
    D'Orlando, S
    Fenu, G
    Menis, R
    Milo, S
    Parisini, T
    PROCEEDINGS OF THE 40TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-5, 2001, : 167 - 172