Study on the influence of transverse effect on strain monitoring of space station

被引:4
|
作者
Shen, Jingshi [1 ,2 ]
Wang, Ting [1 ]
Luo, Yuxiang [2 ]
Zeng, Xiaodong [1 ]
Cao, Changqing [1 ]
机构
[1] Xidian Univ, Sch Phys & Optoelect Engn, Xian 710071, Peoples R China
[2] Shandong Inst Space Elect Technol, Yantai 264670, Peoples R China
来源
OPTIK | 2019年 / 178卷
关键词
Strain measurement; FBG sensors; Transverse effect;
D O I
10.1016/j.ijleo.2018.09.087
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The main tasks of the space station are to execute the manned space flight activities, scientific experiments, observation of astronomical phenomena, and maintenance of satellites for a long time. For a lot of scientific applications, it is necessary to increase the pressure in the cabin, which leads to the difference between the internal and external pressure. Then, the strain can be generated. The real-time and accurate monitoring of the strain on the cabin is one of the important factors to ensure the safety of astronauts. In China, it is the first time to measure the strain of the cabin by means of fiber Bragg grating (FBG) sensors. The optical fiber sensor has a measurement error of less than 4.52 is in the circumferential direction as compared with a resistance strain gauge acted as a reference. But the axial measurement error is very big, and the maximum is 28.93 mu epsilon. As a comparison, the strain of bare fiber in the axial direction is measured, and it is found that the error is terribly small. According to theoretical calculations, the transverse effect coefficient is 0.0271, and the experimental result is 0.0287. These two values are approximately consistent. By compensating the transverse effect of the FBG sensor, the measurement error is decreased by about one order of magnitude. It will be conducive to accomplish the health monitoring and condition assessment of space station.
引用
收藏
页码:794 / 801
页数:8
相关论文
共 50 条
  • [41] An on-board TLD system for dose monitoring on the international space station
    Apáthy, I
    Deme, S
    Bodnár, L
    Csöke, A
    Héjja, I
    RADIATION PROTECTION DOSIMETRY, 1999, 84 (1-4) : 321 - 323
  • [42] Spacecraft Charging and an Instrument for its monitoring aboard the International Space Station
    Kirov, Boian
    Georgieva, Katya
    Vassilev, Vesselin
    ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM PROCEEDINGS 2010, 2010,
  • [43] Relativistic electron precipitation at International Space Station: Space weather monitoring by Calorimetric Electron Telescope
    Kataoka, Ryuho
    Asaoka, Yoichi
    Torii, Shoji
    Terasawa, Toshio
    Ozawa, Shunsuke
    Tamura, Tadahisa
    Shimizu, Yuki
    Akaike, Yosui
    Mori, Masaki
    GEOPHYSICAL RESEARCH LETTERS, 2016, 43 (09) : 4119 - 4125
  • [44] A Study of DTN for Reliable Data Delivery From Space Station to Ground Station
    Wang, Ruhai
    Liu, Xingya
    Yang, Lei
    Xi, Yuanrong
    De Sanctis, Mauro
    Zhao, Kanglian
    Yang, Hong
    Burleigh, Scott C.
    IEEE JOURNAL ON SELECTED AREAS IN COMMUNICATIONS, 2024, 42 (05) : 1344 - 1358
  • [45] EFFECT OF GRAVITY GRADIENT ON ATTITUDE CONTROL OF A SPACE STATION
    LISKA, DJ
    ZIMMERMA.WH
    JOURNAL OF SPACECRAFT AND ROCKETS, 1965, 2 (03) : 419 - &
  • [46] MODELING THE HEART FROM ECHOCARDIOGRAPHIC STRAIN DATA, COLLECTED ON THE INTERNATIONAL SPACE STATION
    Gladding, Patrick A.
    Anwar, Shafkat
    Negishi, Kazuaki
    Popovic, Zoran
    Hussan, Jagir R.
    Marwick, Thomas
    Hunter, Peter
    Kassemi, Mohammed
    Levine, Benjamin
    Thomas, Jim
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (14) : E1255 - E1255
  • [47] FEASIBILITY STUDY OF AN EXPERT SYSTEM FOR A SPACE STATION AND EXPERIMENTS IN SPACE.
    Ogino, T.
    Ijichi, K.
    Space Technology (Oxford), 1987, 7 (04): : 273 - 279
  • [48] EFFECT OF SPACE-CHARGE ON TRANSVERSE INSTABILITIES IN SYNCHROTRONS
    BLASKIEWICZ, M
    WENG, WT
    PHYSICAL REVIEW E, 1994, 50 (05): : 4030 - 4040
  • [49] Study on seismic performance of transverse frame of prefabricated elevated subway station
    Wei, Kelun
    Xu, Yazhou
    Li, Mingtao
    STRUCTURES, 2022, 42 : 255 - 267
  • [50] A Potential Drop Strain Sensor for In-Situ Power Station Creep Monitoring
    Corcoran, Joseph
    Cawley, Peter
    Nagy, Peter B.
    40TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 10TH INTERNATIONAL CONFERENCE ON BARKHAUSEN NOISE AND MICROMAGNETIC TESTING, VOLS 33A & 33B, 2014, 1581 : 1482 - 1487