Reduce Response Time of Single-Phase Dynamic Voltage Restorer (DVR) in a Wide Range of Operating Conditions for Practical Application

被引:11
|
作者
Zhang, Houkai [1 ]
Xiao, Guochun [1 ]
Lu, Zhaolin [1 ]
Chai, Yubing [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
关键词
Power quality; Time factors; Thyristors; Voltage fluctuations; Switches; Delay effects; Standards; Commuting; detection; dynamic voltage restorer (DVR); practical application; response time; voltage sag;
D O I
10.1109/JESTPE.2021.3119947
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Voltage sag is one of the most serious power quality (PQ) problems for many loads; thus, the dynamic voltage restorer (DVR) is developed to mitigate the impact of voltage sag. However, in the practical application nowadays, according to the recent survey, for many sensitive loads, the requirement on the response time of the DVR has been even stricter (shorter in a wider range of operating conditions). Focusing on the single-phase system, the study on reducing the response time of the single-phase DVR in a wide range of operating conditions is introduced in this article. Considering the state of the art, key approaches and ideas to reduce the response time of the DVR in a wide range of operating conditions are discussed, based on which a fast detection method for the grid voltage sag based on the comparisons [combined with bool signal filters (BSFs)] of the multitimescale variables of the restructured voltages, as well as a fast and reliable commuting strategy for the bypass thyristors in the DVR based on the double-voltage-step method, is proposed in this article. The proposed detection method is capable of detecting the grid voltage sag with the time delay about 0.75 ms in a wide range of operating conditions, and the proposed commuting strategy is capable of fast turning off the bypass thyristors in the DVR reliably even with the unreliable sampled current. Then, with the widely used double-closed-loop control with double feedforward, the response time is achieved less than 3 ms in a wide range of operating conditions in a prototype of the single-phase DVR, verifying the feasibility and the performance of the proposed detection method and the commuting strategy.
引用
收藏
页码:2101 / 2113
页数:13
相关论文
共 50 条
  • [21] Measurement and Compensation of Voltage Sag Employing open-loop Single-Phase Dynamic Voltage Restorer
    Mohan P. Thakre
    Payal S. Borse
    Manoj D. Patil
    Yogesh V. Mahadik
    MAPAN, 2022, 37 : 107 - 118
  • [22] Measurement and Compensation of Voltage Sag Employing open-loop Single-Phase Dynamic Voltage Restorer
    Thakre, M. P.
    Borse, P. S.
    Patil, M. D.
    Mahadik, Y., V
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2022, 37 (01): : 107 - 118
  • [23] Development of high-performance single-phase line-interactive dynamic voltage restorer
    Bae, B. Y.
    Lee, D. K.
    Han, B. M.
    2007 AUSTRALASIAN UNIVERSITIES POWER ENGINEERING, VOLS 1-2, 2007, : 659 - +
  • [24] Elliptical restoration based single-phase dynamic voltage restorer for source power factor correction
    Ye, Jian
    Gooi, Hoay Beng
    Wang, Benfei
    Li, Yuanzheng
    Liu, Yun
    ELECTRIC POWER SYSTEMS RESEARCH, 2019, 166 : 199 - 209
  • [25] Line-Interactive Single-Phase Dynamic Voltage Restorer With Novel Sag Detection Algorithm
    Bae, B.
    Lee, J.
    Jeong, J.
    Han, B.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) : 2702 - 2709
  • [26] A Single-Phase Single-Stage Three-Level AC/DC Resonant Converter Operating with a Wide Output Voltage Range
    Kim, Eunsoo
    Marius, Takongmo
    Kim, Minji
    Oh, Jaesung
    Lee, Gangwoo
    Hwang, Ingab
    THIRTY-FOURTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC 2019), 2019, : 2035 - 2039
  • [27] Model Predictive Control of Packed U Cells based Transformerless Single-Phase Dynamic Voltage Restorer
    Trabelsi, Mohamed
    Komurcugil, Hasan
    Refaat, Shady S.
    Abu-Rub, Haitham
    2018 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), 2018, : 1926 - 1931
  • [28] Application of step-dynamic voltage regulator to single-phase system
    Liu, JW
    Choi, SS
    Chen, S
    POWERCON 2002: INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY, VOLS 1-4, PROCEEDINGS, 2002, : 1461 - 1466
  • [29] A New Dynamic Voltage Restorer Structure Based on Three-Phase to Single-Phase AC/AC Matrix Converter
    Zargar, Alireza
    Barakati, S. Masoud
    2015 20TH CONFERENCE ON ELECTRICAL POWER DISTRIBUTION NETWORKS CONFERENCE (EPDC), 2015, : 234 - 238
  • [30] Modeling and Simulation of a Single Phase Transformer Less Dynamic Voltage Restorer (TDVR) For Domestic Application
    Benhail, Arun
    Kumar, Venkatesh
    2017 INTERNATIONAL CONFERENCE ON INNOVATIONS IN ELECTRICAL, ELECTRONICS, INSTRUMENTATION AND MEDIA TECHNOLOGY (ICIEEIMT), 2017, : 364 - 366