Reduce Response Time of Single-Phase Dynamic Voltage Restorer (DVR) in a Wide Range of Operating Conditions for Practical Application

被引:11
|
作者
Zhang, Houkai [1 ]
Xiao, Guochun [1 ]
Lu, Zhaolin [1 ]
Chai, Yubing [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Elect Engn, Xian 710049, Peoples R China
关键词
Power quality; Time factors; Thyristors; Voltage fluctuations; Switches; Delay effects; Standards; Commuting; detection; dynamic voltage restorer (DVR); practical application; response time; voltage sag;
D O I
10.1109/JESTPE.2021.3119947
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Voltage sag is one of the most serious power quality (PQ) problems for many loads; thus, the dynamic voltage restorer (DVR) is developed to mitigate the impact of voltage sag. However, in the practical application nowadays, according to the recent survey, for many sensitive loads, the requirement on the response time of the DVR has been even stricter (shorter in a wider range of operating conditions). Focusing on the single-phase system, the study on reducing the response time of the single-phase DVR in a wide range of operating conditions is introduced in this article. Considering the state of the art, key approaches and ideas to reduce the response time of the DVR in a wide range of operating conditions are discussed, based on which a fast detection method for the grid voltage sag based on the comparisons [combined with bool signal filters (BSFs)] of the multitimescale variables of the restructured voltages, as well as a fast and reliable commuting strategy for the bypass thyristors in the DVR based on the double-voltage-step method, is proposed in this article. The proposed detection method is capable of detecting the grid voltage sag with the time delay about 0.75 ms in a wide range of operating conditions, and the proposed commuting strategy is capable of fast turning off the bypass thyristors in the DVR reliably even with the unreliable sampled current. Then, with the widely used double-closed-loop control with double feedforward, the response time is achieved less than 3 ms in a wide range of operating conditions in a prototype of the single-phase DVR, verifying the feasibility and the performance of the proposed detection method and the commuting strategy.
引用
收藏
页码:2101 / 2113
页数:13
相关论文
共 50 条
  • [1] Single-phase AC-AC converter operating as a dynamic voltage restorer (DVR)
    Perez, Jorge
    Cardenas, Victor
    Moran, Luis
    Nunez, Ciro
    IECON 2006 - 32ND ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS, VOLS 1-11, 2006, : 2042 - +
  • [2] Fast transient control of single-phase dynamic voltage restorer (DVR) without external DC source
    Ho, Carl N. M.
    Chung, Henry S. H.
    2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, : 1333 - +
  • [3] Fast voltage detection for a single-phase Dynamic Voltage Restorer (DVR) using morphological low-pass filters
    Zhou, Hui
    Zhou, jing
    Qi, Zhi-ping
    2008 THIRD INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES, VOLS 1-6, 2008, : 2042 - 2046
  • [4] Design and control of single-phase dynamic voltage restorer
    Amit Meena
    Shirazul Islam
    Sandeep Anand
    Yogesh Sonawane
    Sanjay Tungare
    Sādhanā, 2017, 42 : 1363 - 1375
  • [5] Design and control of single-phase dynamic voltage restorer
    Meena, Amit
    Islam, Shirazul
    Anand, Sandeep
    Sonawane, Yogesh
    Tungare, Sanjay
    SADHANA-ACADEMY PROCEEDINGS IN ENGINEERING SCIENCES, 2017, 42 (08): : 1363 - 1375
  • [6] A Method of Voltage Detection Specific to Single-Phase Dynamic Voltage Restorer
    Gai, Kuo
    Bi, Kaitao
    Fan, Shaogui
    Sun, Li
    2017 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO, ASIA-PACIFIC (ITEC ASIA-PACIFIC), 2017, : 1 - 4
  • [7] Algorithm and simulation to detect voltage for single-phase dynamic voltage restorer
    Zhang, Guo-Rong
    Ding, Ming
    Liang, Hai-Tao
    Lu, Shi-Xiang
    Chen, Ji-Liang
    Xu, Hua-Li
    Xitong Fangzhen Xuebao / Journal of System Simulation, 2007, 19 (04): : 732 - 734
  • [8] Impedance Modeling and Analysis of Single-Phase Dynamic Voltage Restorer
    Zhang, Houkai
    Xiao, Guochun
    Ning, Gaidi
    Wang, Youyun
    Ma, Baohui
    2018 IEEE INTERNATIONAL POWER ELECTRONICS AND APPLICATION CONFERENCE AND EXPOSITION (PEAC), 2018, : 2238 - 2242
  • [9] Control Strategy for Single-phase Rectifier of Dynamic Voltage Restorer
    Wang Yong
    PROCEEDINGS OF THE 29TH CHINESE CONTROL CONFERENCE, 2010, : 3586 - 3589
  • [10] Study on compound control technology of single-phase dynamic voltage restorer
    Shi, Ye
    Wu, Zaijun
    Dou, Xiaobo
    Hu, Minqiang
    Zhao, Bo
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (17): : 85 - 95