Indicator and calibration material for micro calcifications in dual-energy mammography

被引:0
|
作者
Chen, Xi [1 ]
Men, Xuanqin [1 ]
Zhang, Lei [2 ]
机构
[1] Xi An Jiao Tong Univ, Inst Image Proc & Pattern Recognit, Xian 710049, Shaanxi, Peoples R China
[2] Hong Kong Polytech Univ, Dept Comp, Kowloon, Peoples R China
来源
关键词
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
Dual-energy mammography can suppress the contrast between adipose and glandular tissues and improve the detectability of microcalcifications (MCs). In the published papers, MCs were calibrated by aluminum and identified by their thickness. However, the variety of compositions of MCs causes the variety of attenuation differences between MCs and MC calibration material which bring about huge calculation errors. In our study, we selected calcium carbonate and calcium phosphate as the most suitable MC calibration materials and the correction coefficient was reasonably determined. Area density was used as MC indicator instead of thickness. Therefore, the calculation errors from MC calibration materials can be reduced a lot and the determination of MCs will become possible.
引用
收藏
页码:265 / +
页数:2
相关论文
共 50 条
  • [41] Postmortem validation of breast density using dual-energy mammography
    Molloi, Sabee
    Ducote, Justin L.
    Ding, Huanjun
    Feig, Stephen A.
    MEDICAL PHYSICS, 2014, 41 (08) : 439 - 448
  • [42] Glandular dose in contrast-enhanced dual-energy mammography
    Cossu, E.
    Castellani, F.
    Fiaschetti, V.
    Mariateresa, M.
    Tiziana, R.
    Angelo, T.
    CANCER RESEARCH, 2019, 79 (04)
  • [43] DUAL-ENERGY DIVIDING METOD OF THE EARLY DETECTION OF MICROCALCIFICATIONS IN MAMMOGRAPHY
    Gorshkov, V. A.
    Rozhkova, N. I.
    Prokopenko, S. P.
    10TH EUROPEAN CONFERENCE ON NON-DESTRUCTIVE TESTING 2010 (ECNDT), VOLS 1-5, 2010, : 1267 - 1274
  • [44] Cascaded systems analysis of anatomic noise in digital mammography and dual-energy digital mammography
    Tanguay, Jesse
    Lalonde, Robert
    Bjarnason, Thorarin A.
    Yang, Chang-Ying Joseph
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [45] Dual-energy iterative reconstruction for material characterisation
    Recur, B.
    Paziresh, M.
    Myers, G.
    Kingston, A.
    Latham, S.
    Sheppard, A.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [46] AN ACCURATE METHOD FOR DIRECT DUAL-ENERGY CALIBRATION AND DECOMPOSITION
    CARDINAL, HN
    FENSTER, A
    MEDICAL PHYSICS, 1990, 17 (03) : 327 - 341
  • [47] Material classification based on Dual-Energy Micro-CT images by the Gaussian mixture model
    Mami-Zadeh, H.
    Solgi, R.
    Carrier, J-F
    Ghadiri, H.
    JOURNAL OF INSTRUMENTATION, 2022, 17 (02)
  • [48] Dual-energy digital mammography for calcification imaging: Improvement by image processing
    Kappadath, S
    Shaw, C
    MEDICAL PHYSICS, 2005, 32 (06) : 2065 - 2066
  • [49] Image noise sensitivity of dual-energy digital mammography for calcification imaging
    Chen, Xi
    Nishikawa, Robert M.
    Chan, Suk-tak
    Zhang, Lei
    Mou, Xuanqin
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [50] Breast Density Quantification Using Liquid Phantoms with Dual-Energy Mammography
    Ng, A. Lam
    Ding, H.
    Molloi, S.
    MEDICAL PHYSICS, 2013, 40 (06)