Time delay consideration for robust capacitor-current-inner-loop active damping of LCL-filter-based grid-connected converters

被引:11
|
作者
Ben Said-Romdhane, M. [1 ]
Naouar, M. W. [1 ]
Slama-Belkhodja, I. [1 ]
Monmasson, E. [2 ]
机构
[1] Univ Tunis El Manar, Ecole Natl Ingn Tunis, Lab Syst Elect LR11ES15, Tunis 1002, Tunisia
[2] Univ Cergy Pontoise, SATIE, 33 Bd Port, F-95000 Cergy Pontoise, France
关键词
LCL filter; Grid connected converters; Capacitor Current Inner Loop Active; Damping; Digital controllers; Time delay; Controllers design; Current control; Grid impedance variation; INVERTER; DESIGN; STABILITY; MODE;
D O I
10.1016/j.ijepes.2017.08.026
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to its higher switching frequency current harmonics attenuation, the LCL filter is extensively adopted in Grid connected Converters (GcCs). To cope with its inherent resonance phenomena, the Capacitor Current Inner Loop Active Damping (CCIL-AD) is typically employed to actively damp the LCL filter resonant peak. However, the time delay (t(d)) related to digital controllers modifies the Active Damping (AD) characteristics, resulting in reduced phase margin as well as poor dynamic and steady-state performances of the system. Moreover, high variations in the grid inductance, mainly under weak grid conditions, may threaten the system stability. In view of this, this paper proposes a robust design approach for voltage oriented PI control associated to CCIL-AD for LCL-filter-based Grid-connected Converters (LCL-GcCs). The aim of the considered approach is to ensure robust stability margins, fast transient response and reduced steady-state error even under severe grid inductance changes, digital time delay and LCL filter parameters variations. The proposed approach has been validated by simulation and experimental tests based on a 4-kW three-phase converter laboratory prototype. The obtained simulation and experimental results indicate the efficiency and the robustness of the proposed design approach. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:177 / 187
页数:11
相关论文
共 50 条
  • [21] Active Damping Control Strategy for Grid-connected Inverters by Splitting the Capacitor of LCL Filter
    Ling Lu
    Ye Yongqiang
    Zhuang Chao
    Wang Jianhong
    26TH CHINESE CONTROL AND DECISION CONFERENCE (2014 CCDC), 2014, : 4805 - 4810
  • [22] Robust multisampled capacitor voltage active damping for grid-connected power converters
    Samanes, Javier
    Urtasun, Andoni
    Gubia, Eugenio
    Petri, Alberto
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 105 : 741 - 752
  • [23] Analysis of the Passive Damping Losses in LCL-Filter-Based Grid Converters
    Pena-Alzola, Rafael
    Liserre, Marco
    Blaabjerg, Frede
    Sebastian, Rafael
    Dannehl, Jorg
    Fuchs, Friedrich Wilhelm
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) : 2642 - 2646
  • [24] Adaptive Current Control for Grid-Connected Converters With LCL Filter
    Massing, Jorge Rodrigo
    Stefanello, Marcio
    Gruendling, Hilton Abilio
    Pinheiro, Humberto
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (12) : 4681 - 4693
  • [25] Synthesis of Active Damping for Grid-Connected Inverters with an LCL filter
    Xiao, Huafeng
    Qu, Xiaohui
    Xie, Shaojun
    Xu, Jinming
    2012 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2012, : 550 - 556
  • [26] Damping techniques for grid-connected voltage source converters based on LCL filter: An overview
    Gomes, Camilo C.
    Cupertino, Allan F.
    Pereira, Heverton A.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2018, 81 : 116 - 135
  • [27] A Two State Feedback Active Damping Strategy for the LCL Filter Resonance in Grid-Connected Converters
    Gaafar, Mahmoud A.
    Ahmed, Emad M.
    Shoyama, Masahito
    JOURNAL OF POWER ELECTRONICS, 2016, 16 (04) : 1587 - 1597
  • [28] Complete Time-Delay Compensation Method for LCL-Type Grid-Connected Inverter with Capacitor-Current Active Damping
    Li, Shaojie
    Lin, Hua
    Wang, Xingwei
    Hua, Ting
    2021 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2021, : 3484 - 3489
  • [29] A New Feedback Method for PR Current Control of LCL-Filter-Based Grid-Connected Inverter
    Shen, Guoqiao
    Zhu, Xuancai
    Zhang, Jun
    Xu, Dehong
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2010, 57 (06) : 2033 - 2041
  • [30] An Improved Capacitor-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Inverters
    Liu, Teng
    Liu, Zeng
    Liu, Jinjun
    Tu, Yiming
    Liu, Zipeng
    2017 IEEE 3RD INTERNATIONAL FUTURE ENERGY ELECTRONICS CONFERENCE AND ECCE ASIA (IFEEC 2017-ECCE ASIA), 2017, : 2111 - 2116