The importance of 3D dosimetry

被引:22
|
作者
Low, Daniel [1 ]
机构
[1] UCLA Radiat Oncol, Los Angeles, CA 90095 USA
关键词
DIODE-ARRAY; IMRT;
D O I
10.1088/1742-6596/573/1/012009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiation therapy has been getting progressively more complex for the past 20 years. Early radiation therapy techniques needed only basic dosimetry equipment; motorized water phantoms, ionization chambers, and basic radiographic film techniques. As intensity modulated radiation therapy and image guided therapy came into widespread practice, medical physicists were challenged with developing effective and efficient dose measurement techniques. The complex 3-dimensional (3D) nature of the dose distributions that were being delivered demanded the development of more quantitative and more thorough methods for dose measurement. The quality assurance vendors developed a wide array of multidetector arrays that have been enormously useful for measuring and characterizing dose distributions, and these have been made especially useful with the advent of 3D dose calculation systems based on the array measurements, as well as measurements made using film and portal imagers. Other vendors have been providing 3D calculations based on data from the linear accelerator or the record and verify system, providing thorough evaluation of the dose but lacking quality assurance (QA) of the dose delivery process, including machine calibration. The current state of 3D dosimetry is one of a state of flux. The vendors and professional associations are trying to determine the optimal balance between thorough QA, labor efficiency, and quantitation. This balance will take some time to reach, but a necessary component will be the 3D measurement and independent calculation of delivered radiation therapy dose distributions.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] PRESAGE - A promising new material for 3D dosimetry
    Guo, P
    Adamovics, J
    Oldham, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S206 - S206
  • [22] Investigation of a bleaching dye for 3D radiochromic dosimetry
    Hoye, E.
    Skyt, P. S.
    Muren, L. P.
    Petersen, J. B. B.
    Balling, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S142 - S142
  • [23] 3D DOSIMETRY SYSTEMS - GELS, EPIDS AND OTHERS
    Duchateau, M.
    Verellen, D.
    Depuydt, T.
    Tournel, K.
    Reynders, T.
    Gevaert, T.
    Leysen, K.
    Gulyban, A.
    Poels, K.
    De Ridder, M.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S27 - S27
  • [24] 3D DOSIMETRIC VERIFICATION OF VMAT BY PORTAL DOSIMETRY
    Mans, A.
    Wendling, M.
    Stroom, J.
    Remeijer, P.
    Sonke, J. J.
    Mijnheer, B.
    van Herk, M.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S25 - S26
  • [25] Clinical 3D Dosimetry in Modern Radiation Therapy
    Mihailidis, Dimitris
    MEDICAL PHYSICS, 2020, 47 (01) : 290 - 291
  • [26] 3D Dosimetry in the Clinic: Validating Special Techniques
    Juang, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3695 - 3695
  • [27] 3D IN VIVO DOSIMETRY IN TOMOTHERAPY: FIRST RESULTS
    Schombourg, K.
    Bochud, F.
    Moeckli, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 (09) : 636 - 636
  • [28] Development of an automatic processing application for 3D Dosimetry
    Isidoro, J.
    Rachinhas, P. J. B. M.
    Cavaco, A.
    Freitas, D.
    Paiva, R.
    Costa, G.
    Lima, J. M. P.
    Ferrer-Antunes, A.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2007, 34 : S178 - S178
  • [29] A 3D imaging system for dosimetry in FLASH radiotherapy
    Ravera, Eleonora
    Anzalone, Rebecca
    Cavalieri, Andrea
    Ciarrocchi, Esther
    Del Sarto, Damiano
    Di Martino, Fabio
    Morrocchi, Matteo
    Bisogni, Maria Giuseppina
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1069
  • [30] Investigation of 3D gram materials for radiation dosimetry
    Readshaw, AK
    Brown, GO
    Phillips, GW
    Weiss, RG
    Guardala, NA
    Price, JL
    Mueller, SC
    Moscovitch, M
    RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) : 451 - 454