The importance of 3D dosimetry

被引:22
|
作者
Low, Daniel [1 ]
机构
[1] UCLA Radiat Oncol, Los Angeles, CA 90095 USA
关键词
DIODE-ARRAY; IMRT;
D O I
10.1088/1742-6596/573/1/012009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Radiation therapy has been getting progressively more complex for the past 20 years. Early radiation therapy techniques needed only basic dosimetry equipment; motorized water phantoms, ionization chambers, and basic radiographic film techniques. As intensity modulated radiation therapy and image guided therapy came into widespread practice, medical physicists were challenged with developing effective and efficient dose measurement techniques. The complex 3-dimensional (3D) nature of the dose distributions that were being delivered demanded the development of more quantitative and more thorough methods for dose measurement. The quality assurance vendors developed a wide array of multidetector arrays that have been enormously useful for measuring and characterizing dose distributions, and these have been made especially useful with the advent of 3D dose calculation systems based on the array measurements, as well as measurements made using film and portal imagers. Other vendors have been providing 3D calculations based on data from the linear accelerator or the record and verify system, providing thorough evaluation of the dose but lacking quality assurance (QA) of the dose delivery process, including machine calibration. The current state of 3D dosimetry is one of a state of flux. The vendors and professional associations are trying to determine the optimal balance between thorough QA, labor efficiency, and quantitation. This balance will take some time to reach, but a necessary component will be the 3D measurement and independent calculation of delivered radiation therapy dose distributions.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Fundamentals of 3D dosimetry
    Schreiner, L. J.
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [2] On the reliability of 3D gel dosimetry
    De Deene, Y.
    Vandecasteele, J.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [3] 3D Proton Gel Dosimetry
    Gorjiara, T.
    Kuncic, Z.
    Baldock, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [4] 3D dosimetry for proton therapy
    Beddar, S.
    10TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2019, 1305
  • [5] Uncertainty in 3D gel dosimetry
    De Deene, Yves
    Jirasek, Andrew
    8TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2015, 573
  • [6] 3D Dosimetry in End-To-End Dosimetry QA
    Ibbott, G.
    MEDICAL PHYSICS, 2016, 43 (06) : 3695 - 3695
  • [7] The importance of the accuracy of image registration of SPECT images for 3D targeted radionuclide therapy dosimetry
    Papavasileiou, Periklis
    Divoli, Antigoni
    Hatziioannou, Konstantinos
    Flux, Glenn D.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (24): : N539 - N548
  • [8] 3D dosimetry using gels and MRI
    Olsson, LE
    Bäck, SÅJ
    Magnusson, P
    Haraldsson, P
    IMAGING IN RADIATION THERAPY, 1998, (24): : 475 - 504
  • [9] 3D Dosimetry in the Clinic: Background and Motivation
    Schreiner, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3695 - 3695
  • [10] A novel methodology for 3D deformable dosimetry
    Yeo, U. J.
    Taylor, M. L.
    Dunn, L.
    Kron, T.
    Smith, R. L.
    Franich, R. D.
    MEDICAL PHYSICS, 2012, 39 (04) : 2203 - 2213