An image registration based ultrasound probe calibration

被引:1
|
作者
Li, Xin [1 ]
Kumar, Dinesh [1 ]
Sarkar, Saradwata [1 ]
Narayanan, Ram [1 ]
机构
[1] Eigen, Grass Valley, CA 95945 USA
来源
MEDICAL IMAGING 2012: IMAGE PROCESSING | 2012年 / 8314卷
关键词
Image Registration; Ultrasound Probe Calibration;
D O I
10.1117/12.911461
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Reconstructed 3D ultrasound of prostate gland finds application in several medical areas such as image guided biopsy, therapy planning and dose delivery [1]. In our application, we use an end-fire probe rotated about its axis to acquire a sequence of rotational slices to reconstruct 3D TRUS (Transrectal Ultrasound) image. The image acquisition system consists of an ultrasound transducer situated on a cradle directly attached to a rotational sensor. However, due to system tolerances, axis of probe does not align exactly with the designed axis of rotation resulting in artifacts in the 3D reconstructed ultrasound volume. We present a rigid registration based automatic probe calibration approach. The method uses a sequence of phantom images, each pair acquired at angular separation of 180 degrees and registers corresponding image pairs to compute the deviation from designed axis. A modified shadow removal algorithm is applied for preprocessing. An attribute vector is constructed from image intensity and a speckle-insensitive information-theoretic feature. We compare registration between the presented method and expert-corrected images in 16 prostate phantom scans. Images were acquired at multiple resolutions, and different misalignment settings from two ultrasound machines. Screenshots from 3D reconstruction are shown before and after misalignment correction. Registration parameters from automatic and manual correction were found to be in good agreement. Average absolute differences of translation and rotation between automatic and manual methods were 0.27 mm and 0.65 degree, respectively. The registration parameters also showed lower variability for automatic registration (pooled standard deviation sigma(translation) = 0.50 mm, sigma(rotation) = 0.52 degree) compared to the manual approach (pooled standard deviation sigma(translation) = 0.62 mm, sigma(rotation) = 0.78 degree).
引用
收藏
页数:8
相关论文
共 50 条
  • [31] A comparision of two similarity measures in intensity-based ultrasound image registration
    Gao, S
    Xiao, Y
    Hu, SH
    2004 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL 4, PROCEEDINGS, 2004, : 61 - 64
  • [32] Robocup field distortion calibration with variational image registration
    Guan, L
    Guo, CG
    Xiong, R
    PROCEEDINGS OF THE 2004 INTERNATIONAL SYMPOSIUM ON INTELLIGENT MULTIMEDIA, VIDEO AND SPEECH PROCESSING, 2004, : 338 - 341
  • [33] Ultrasound Based Deformable Image Registration: Daily CT Images Derived From Daily IGRT Ultrasound
    van der Meer, S.
    Bouvy, D.
    Reniers, B.
    Fontanarosa, D.
    Verhaegen, F.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [34] Probe calibration for freehand 3-D ultrasound
    Lindseth, F
    Tangen, GA
    Lango, T
    Bang, J
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (11): : 1607 - 1623
  • [35] Geometric Calibration of a New Miniaturized Endoscopic Ultrasound Probe
    Santos, Joao Cavalcanti
    Lavenir, Lucas
    Zemiti, Nabil
    Poignet, Philippe
    Venail, Frederic
    2021 20TH INTERNATIONAL CONFERENCE ON ADVANCED ROBOTICS (ICAR), 2021, : 228 - 233
  • [36] A Model-Guided Method for Ultrasound Probe Calibration
    Zhao, Jiasheng
    Li, Haowei
    Yang, Sheng
    Sui, Chaoye
    Ding, Hui
    Wang, Guangzhi
    12TH ASIAN-PACIFIC CONFERENCE ON MEDICAL AND BIOLOGICAL ENGINEERING, VOL 2, APCMBE 2023, 2024, 104 : 10 - 17
  • [37] VIRTUAL MOVEMENTS-BASED CALIBRATION METHOD OF ULTRASOUND PROBE FOR COMPUTER ASSISTED SURGERY
    Chaoui, J.
    Dardenne, G.
    Hamitouche, C.
    Stindel, E.
    Roux, C.
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 1207 - 1210
  • [38] Calibration method by image registration with synthetic image of 3D model
    Tamaki, T
    Yamamoto, M
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2003, E86D (05): : 981 - 985
  • [39] A fast registration method using ip and its application to ultrasound image registration
    Institute of Industrial Science, University of Tokyo, Japan
    不详
    不详
    IPSJ Trans. Comput. Vis. Appl., (209-219):
  • [40] A Novel Ultrasound-Based Registration for Image-Guided Laparoscopic Liver Ablation
    Fusaglia, Matteo
    Tinguely, Pascale
    Banz, Vanessa
    Weber, Stefan
    Lu, Huanxiang
    SURGICAL INNOVATION, 2016, 23 (04) : 397 - 406