Usefulness and pitfalls of planar γ-scintigraphy for measuring aerosol deposition in the lungs:: A Monte Carlo investigation

被引:0
|
作者
Lee, ZH
Ljungberg, M
Muzic, RF
Berridge, MS
机构
[1] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Radiol, Nucl Med Div, Cleveland, OH 44106 USA
[2] Univ Lund Hosp, Dept Radiat Phys, Jubileum Inst, S-22185 Lund, Sweden
关键词
planar scintigraphy; aerosol lung deposition; scatter; attenuation correction;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Planar gamma -scintigraphy is often used to quantify pulmonary deposition patterns from aerosol inhalers. The results are quite different from those obtained using 5-dimensional PET and SPECT. The purpose of this study was to characterize the effects of scatter and tissue attenuation on the distribution of radiolabeled aerosol as measured by planar scintigraphy using Monte Carlo simulations. This study also investigated the applicability of a few correction methods used in inhalation studies. Methods: Body density maps were derived from CT scans. Regions of interest-lungs, major airways, and esophagus-were defined from the same CT volume. Two radioactivity source distribution patterns in the lung, uniform and nonuniform, were used. A Monte Carlo program, SIMIND, was used to generate anterior and posterior gamma -images of the composed inhalation distributions for 2 energy windows, photopeak (127-153 keV) and scatter (92-125 keV). The effects of scatter and attenuation were estimated on the basis of the imaging components separated from the simulation. A scatter correction method and 2 attenuation correction methods, all applied to inhalation scintigraphy, were evaluated using the simulated images. Results: The amount of scatter ranges from 24% to approximately 29% in the lungs and from 29% to approximately 35% in the central (airway or esophagus) region on the planar images. Significant differences were found among regions and between source distributions (P < 0.05), The fraction k used for dual-energy- based scatter correction also varied and was found to be less than the commonly used k = 0.5, The simplified narrow-beam attenuation correction and the effective (broad-beam) correction methods were found to either under- or overcorrect the regional activities. Conclusion: The amount of scatter and tissue attenuation in the thorax region depends on source distribution and body attenuation. In applying planar scintigraphy for aerosol inhalation studies, it is difficult to obtain precise quantitative measurements because of the uncertainties associated with scatter and attenuation corrections. Accurate corrections require knowledge of both source and density distributions.
引用
收藏
页码:1077 / 1083
页数:7
相关论文
共 41 条
  • [31] Investigation of physical vapor deposition techniques of conformal shell coating for core/shell structures by Monte Carlo simulations
    Cansizoglu, H.
    Yurukcu, M.
    Cansizoglu, M. F.
    Karabacak, T.
    THIN SOLID FILMS, 2015, 583 : 122 - 128
  • [32] A combined fluid dynamic and 3D kinetic Monte Carlo investigation of the selective deposition of GaAs and InP
    Rondanini, M
    Cavallotti, C
    Moscatelli, D
    Masi, M
    Carrà, S
    JOURNAL OF CRYSTAL GROWTH, 2004, 272 (1-4) : 52 - 58
  • [33] 3D Simulations on Surface Growth Via Chemical Vapour Deposition: Kinetic Monte Carlo Investigation
    Thongon, Arjaree
    Choopun, Supab
    Yimnirun, Rattikorn
    Laosiritaworn, Yongyut
    INTEGRATED FERROELECTRICS, 2014, 155 (01) : 100 - 105
  • [34] A 3D Monte Carlo Simulation for Aerosol Deposition onto Horizontal Surfaces by Combined Mechanisms of Brownian Diffusion and Gravity Sedimentation
    Wu, Shixian
    Zhu, Hui
    Chen, Yongping
    Qi, Can
    Li, Gang
    ATMOSPHERE, 2022, 13 (09)
  • [35] Evaluating the accuracy of planar scintigraphy LSF and SPECT/CT LSF estimations using Monte Carlo simulations with virtual 4D anthropomorphic phantoms
    Cournane, S.
    McArdle, N.
    McCavana, J.
    McCague, D.
    Vintro, L. Leon
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S259 - S259
  • [36] INFLUENCE OF TRANSPORT PROPERTIES ON ENERGY RESOLUTION OF PLANAR TlBr AND CdZnTe GAMMA-RAY DETECTORS: MONTE-CARLO INVESTIGATION
    Skrypnyk, A. I.
    Khazhmuradov, M. A.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2014, (04): : 134 - 138
  • [37] Segmentation of the body and lungs from compton scatter and photopeak window data in SPECT: A Monte Carlo investigation (vol 15, pg 13, 1996)
    Pan, TS
    King, MA
    deVries, DJ
    Ljungberg, M
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1996, 15 (03) : 394 - 396
  • [38] Investigation of Micron-Scale Radiotherapy Dose Deposition in the Lung: Effect of Magnetic Field and Nanoparticles-a Monte Carlo Simulation
    Montinola, Denxybel
    McNamara, Aimee L.
    Kuncic, Zdenka
    Byrne, Hilary L.
    FRONTIERS IN PHYSICS, 2022, 10
  • [39] Monte Carlo investigation of the role of initial conditions on oxygen diffusion in planar YBa2Cu3O6+c
    Pekalski, A
    Skwarek, K
    PHYSICAL REVIEW B, 1996, 54 (06): : 4315 - 4319
  • [40] Numerical investigation via three-dimensional Monte Carlo modeling of sputtering and deposition processes in a direct current unbalanced magnetron discharge
    Sobbia, R.
    Browning, P. K.
    Bradley, J. W.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A, 2008, 26 (01): : 103 - 113