Implantable cardioverter-defibrillator lead revision following left ventricular assist device implantation

被引:1
|
作者
Black-Maier, Eric [1 ]
Lewis, Robert K. [1 ]
Rehorn, Michael [1 ]
Loungani, Rahul [1 ]
Friedman, Daniel J. [2 ]
Frazier-Mills, Camille [1 ]
Jackson, Kevin P. [1 ]
Atwater, Brett D. [1 ]
Milano, Carmelo A. [3 ]
Schroder, Jacob N. [3 ]
Pokorney, Sean D. [1 ]
Piccini, Jonathan P. [1 ]
机构
[1] Duke Univ, Med Ctr, Div Cardiol, Durham, NC USA
[2] Yale Univ, Sch Med, Div Electrophysiol, New Haven, CT USA
[3] Duke Univ, Med Ctr, Div Cardiothorac Surg, Durham, NC USA
关键词
implantable cardioverter-defibrillator; lead dysfunction; lead revision; left ventricular assist device;
D O I
10.1111/jce.14487
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Lead dysfunction can lead to serious consequences including failure to treat ventricular tachycardia or fibrillation (VT/VF). The incidence and mechanisms of lead dysfunction following left ventricular assist device (LVAD) implantation are not well-described. We sought to determine the incidence, mechanisms, timing, and complications of right ventricular lead dysfunction requiring revision following LVAD implantation. Methods Retrospective observational chart review of all LVAD recipients with pre-existing implantable cardioverter-defibrillator (ICD) from 2009 to 2018 was performed including device interrogation reports, laboratory and imaging data, procedural reports, and clinical outcomes. Results Among 583 patients with an ICD in situ undergoing LVAD implant, the median (interquartile range) age was 62.5 (15.7) years, 21% were female, and the types of LVADs included HeartWare HVAD (26%), HeartMate II (52%), and HeartMate III (22%). Right ventricular lead revision was performed in 38 patients (6.5%) at a median (25th, 75th) of 16.4 (3.6, 29.2) months following LVAD. Mechanisms of lead dysfunction included macrodislodgement (n = 4), surgical lead injury (n = 4), recall (n = 3), insulation failure (n = 8) or conductor fracture (n = 7), and alterations in the lead-myocardial interface (n = 12). Undersensing requiring revision occurred in 22 (58%) cases. Clinical sequelae of undersensing included failure to detect VT/VF (n = 4) and pacing-induced torsade de pointes (n = 1). Oversensing occurred in 12 (32%) and sequelae included inappropriate antitachycardia pacing ([ATP], n = 8), inappropriate ICD shock (n = 6), and ATP-induced VT (n = 1). Conclusion The incidence of right ventricular lead dysfunction following LVAD implantation is significant and has important clinical sequelae. Physicians should remain vigilant for lead dysfunction after LVAD surgery and test lead function before discharge.
引用
收藏
页码:1509 / 1518
页数:10
相关论文
共 50 条
  • [21] Adverse interaction between a left ventricular assist device and an implantable cardioverter defibrillator
    Matthews, Jennifer Cowger
    Betley, Daphne
    Morady, Fred
    Pelosi, Frank, Jr.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (10) : 1107 - 1108
  • [22] Improved survival among ventricular assist device recipients with a concomitant implantable cardioverter-defibrillator
    Cantillon, Daniel J.
    Tarakji, Khaldoun G.
    Kumbhani, Dharam J.
    Smedira, Nicholas G.
    Starling, Randall C.
    Wilkoff, Bruce L.
    HEART RHYTHM, 2010, 7 (04) : 466 - 471
  • [23] Subcutaneous implantable cardioverter-defibrillator troubleshooting in patients with a left ventricular assist device: A case series and systematic review
    Black-Maier, Eric
    Lewis, Robert K.
    Barnett, Adam S.
    Pokorney, Sean D.
    Sun, Albert Y.
    Koontz, Jason I.
    Daubert, James P.
    Piccini, Jonathan P.
    HEART RHYTHM, 2020, 17 (09) : 1536 - 1544
  • [24] Left Ventricular Assist Device in a Patient With a Concomitant Subcutaneous Implantable Cardioverter Defibrillator
    Saeed, Diyar
    Albert, Alexander
    Westenfeld, Ralf
    Maxhera, Bujar
    Gramsch-Zabel, Hildegard
    O'Connor, Stephen
    Lichtenberg, Artur
    Winter, Joachim
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (03): : E32 - E33
  • [25] Implantable cardioverter-defibrillator after left ventricular reconstruction?
    Sartipy, U
    Albåge, A
    Lindblom, D
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05): : 1210 - 1211
  • [26] Implantable cardioverter-defibrillator shocks in patients with ventricular assist devices
    Gkouziouta, A.
    Katsianis, A.
    Kostopoulou, A.
    Cokkinos, P. H.
    Karavolias, G.
    Maounis, T. H.
    Livanis, E.
    Theodorakis, G.
    Sfirakis, P.
    Adamopoulos, S.
    EUROPEAN HEART JOURNAL, 2013, 34 : 259 - 260
  • [27] Implantation of the Right Ventricular Lead of an Implantable Cardioverter-Defibrillator Complicated by Apical Myocardial Infarction
    Nishiyama, Nobuhiro
    Takatsuki, Seiji
    Kimura, Takehiro
    Aizawa, Yoshiyasu
    Fukumoto, Kotaro
    Hagiwara, Yoko
    Tanimoto, Kojiro
    Fukuda, Keiichi
    CIRCULATION, 2012, 126 (10) : 1314 - 1315
  • [28] Electromagnetic Interference from Left Ventricular Assist Device (LVAD) Inhibiting the Pacing Function of an Implantable Cardioverter-Defibrillator (ICD) Device
    Erqou, Sebhat
    Kormos, Robert L.
    Wang, Norman C.
    McNamara, Dennis M.
    Bazaz, Raveen
    CASE REPORTS IN CARDIOLOGY, 2018, 2018
  • [29] Implantation of the right ventricular lead of implantable cardioverter-defibrillator complicated by apical myocardial infarction
    Nishiyama, N.
    Takatsuki, S.
    Kimura, T.
    Aizawa, Y.
    Fukumoto, K.
    Tanimoto, Y.
    Tanimoto, K.
    Fukuda, K.
    EUROPEAN HEART JOURNAL, 2012, 33 : 1116 - 1116
  • [30] IMPLANTABLE CARDIOVERTER DEFIBRILLATOR IMPLANTATION IMPROVES OUTCOME OF PATIENTS WITH LEFT VENTRICULAR ASSIST DEVICES
    Agrawal, Sahil
    Nanda, Sudip
    Garg, Lohit
    Manda, Yugandhar
    Singh, Amitoj
    Sinha, Archana
    Vefali, Huseng
    Quddus, Abdullah
    Shirani, Jamshid
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1269 - 1269