Construction of effective disposable biosensors for point of care testing of nitrite

被引:29
|
作者
Monteiro, Tiago [1 ,2 ]
Rodrigues, Patricia R. [2 ]
Goncalves, Ana Luisa [2 ]
Moura, Jose J. G. [2 ]
Jubete, Elena [3 ]
Anorga, Larraitz [3 ]
Piknova, Barbora [4 ]
Schechter, Alan N. [4 ]
Silveira, Celia M. [2 ,5 ]
Gabriela Almeida, M. [1 ,2 ]
机构
[1] Inst Super Ciencias Saude Egas Moniz, Ctr Invest Interdisciplinar Egas Moniz CiiEM, P-2829511 Caparica, Portugal
[2] Univ Nova Lisboa, Fac Ciencias & Tecnol, REQUIMTE, UCIBIO, P-2829516 Monte De Caparica, Portugal
[3] IK4 CIDETEC, Div Mat, Sensors Unit, Donostia San Sebastian 20009, Spain
[4] NIDDK, Mol Med Branch, NIH, Bethesda, MD 20892 USA
[5] Univ Nova Lisboa, Inst Tecnol Quim & Biol, P-2780157 Oeiras, Portugal
关键词
Point of care testing; Nitrite; Cytochrome c nitrite reductase; Biosensors; Screen printed electrodes; Carbon conductive ink; ELECTROCHEMICAL CHARACTERIZATION; CARBON NANOFIBER; REDUCTASE; NITRATE; LACTATE; BIOLOGY; SYSTEMS;
D O I
10.1016/j.talanta.2015.04.057
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper we aim to demonstrate, as a proof-of-concept, the feasibility of the mass production of effective point of care tests for nitrite quantification in environmental, food and clinical samples. Following our previous work on the development of third generation electrochemical biosensors based on the ammonia forming nitrite reductase (ccNiR), herein we reduced the size of the electrodes' system to a miniaturized format, solved the problem of oxygen interference and performed simple quantification assays in real samples. In particular, carbon paste screen printed electrodes (SPE) were coated with a ccNiR/carbon ink composite homogenized in organic solvents and cured at low temperatures. The biocompatibility of these chemical and thermal treatments was evaluated by cyclic voltammetry showing that the catalytic performance was higher with the combination acetone and a 40 degrees C curing temperature. The successful incorporation of the protein in the carbon ink/solvent composite, while remaining catalytically competent, attests for ccNiR's robustness and suitability for application in screen printed based biosensors. Because the direct electrochemical reduction of molecular oxygen occurs when electroanalytical measurements are performed at the negative potentials required to activate ccNiR (ca. - 0.4 V vs Ag/AgCl), an oxygen scavenging system based on the coupling of glucose oxidase and catalase activities was successfully used. This enabled the quantification of nitrite in different samples (milk, water, plasma and urine) in a straightforward way and with small error (1-6%). The sensitivity of the biosensor towards nitrite reduction under optimized conditions was 0.55 A M-1 cm(-2) with a linear response range 0.7-370 mu M. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:246 / 251
页数:6
相关论文
共 50 条
  • [31] Disposable polymer "smart" lab-on-a-chip for point-of-care testing (POCT) in clinical diagnostics
    Ahn, CH
    TRANSDUCERS '05, DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2005, : 437 - 440
  • [32] Development and Initial Results of a Low Cost, Disposable, Point-of-Care Testing Device for Pathogen Detection
    Bearinger, Jane P.
    Dugan, Lawrence C.
    Baker, Brian R.
    Hall, Sara B.
    Ebert, Katja
    Mioulet, Valerie
    Madi, Mikidache
    King, Donald P.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2011, 58 (03) : 805 - 808
  • [33] Point of care testing
    Aulois-Griot, M
    Billion, P
    Calestreme, P
    Coquelin, H
    Daunizeau, A
    Del Corso, A
    Duchassaing, D
    Jacob, JL
    Lafond, JL
    ANNALES DE BIOLOGIE CLINIQUE, 1998, 56 (01) : 114 - 115
  • [34] POINT OF CARE TESTING
    Barton, S.
    SEXUAL HEALTH, 2009, 6 (04) : 358 - 358
  • [35] Point of care testing
    Nichols, James H.
    CLINICS IN LABORATORY MEDICINE, 2007, 27 (04) : 893 - +
  • [36] Point of care testing
    Dhondt, JL
    ANNALES DE BIOLOGIE CLINIQUE, 1998, 56 (04) : 392 - 393
  • [37] A disposable sensor for point of care wound pH monitoring
    Phair, Jolene
    Newton, Laura
    McCormac, Cliodhna
    Cardosi, Marco F.
    Leslie, Ray
    Davis, James
    ANALYST, 2011, 136 (22) : 4692 - 4695
  • [38] Point-of-Care-Testing Point-of-Care-Testing and Hemotherapy Algorithms
    Brenner, Thorsten
    Hofer, Stefan
    ANASTHESIOLOGIE INTENSIVMEDIZIN NOTFALLMEDIZIN SCHMERZTHERAPIE, 2013, 48 (05): : 336 - 343
  • [39] Printable biosensors towards next-generation point-of-care testing: paper substrate as an example
    Liu, Yaolin
    Lu, Sheng
    Zhang, Zhiheng
    Yang, Zhugen
    Cui, Xiaolin
    Liu, Guozhen
    LAB ON A CHIP, 2023, 23 (15) : 3328 - 3352
  • [40] The point of point-of-care testing
    Kassaye, Seble G.
    Katzenstein, David
    LANCET, 2011, 378 (9802): : 1532 - 1533