Experimental investigation of performance of obstruction flow-meters designed with theoretical methods and computational fluid dynamics

被引:0
|
作者
Kucuk, Hasan [1 ]
Unverdi, Murat [2 ]
机构
[1] Sakarya Univ, Makine Muhendisligi Bolumu, Muhendislik Fak, Sakarya, Turkey
[2] Adnan Menderes Univ, Makine Met Teknol Bolumu, Aydin Meslek Yuksekokulu, Aydin, Turkey
关键词
Flow nozzle; Orifice plate; Flow straightener (Flow conditioner); Flow rate measurement; Computational fluid dynamics; Additive manufacturing;
D O I
10.5505/pajes.2021.22844
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The aim of this study was to design obstruction flow meters to measure and control the volumetric flow of air, to manufacture them with additive manufacturing (3D printer) and to compare numerical and experimental performance. An ASME long radius low ft flow nozzle and sharp-edge orifice was the obstruction flow meter of choice due to ease of design and manufacture and common use. This study employed Computational Fluid Dynamics (CFD) to compare the numerical performance of 3D flow meters, whose geometric dimensions are determined using current design methods in the literature. Experiments were performed to calculate the performance of the obstruction flow meters produced using additive manufacturing. The inner diameter of the flow channel (152 mm) was based on the volume flow rate of 80 to 300 m(3)/h and the Reynolds number of 12,000 to 46,000 at the inlet of the flow meters. The ratio of the flow cross section diameter (d) of the flow meters to the channel cross section diameter (D) was beta-0.45 to limit pressure losses. The effectiveness of the tube bundle-type flow straightener and the effect of the distance between the flow meters and fans downstream of the flow meter on measurements were also investigated in the experiments to develop the flow at the upstream of the flow meters at a shorter distance and to shorten the tube length. The numerical results agreed with the theoretical design calculations with an average difference of 1.6% in the flow nozzle and an average difference of 7.8% in the orifice. The experimental results also agreed with the theoretical results with an average difference of 8% in the flow nozzle and an average difference of 14.3% in the orifice. The mean difference between the numerical and experimental results was 7.3% and 14.8% in the flow nozzle and orifice, respectively. Volume flow rate equations based on pressure drops were developed using the experimental results of both flow meters.
引用
收藏
页码:37 / 50
页数:14
相关论文
共 50 条
  • [31] Computational and experimental investigation of flow and fluid mixing in the roller bottle bioreactor
    Unger, DR
    Muzzio, FJ
    Aunins, JG
    Singhvi, R
    BIOTECHNOLOGY AND BIOENGINEERING, 2000, 70 (02) : 117 - 130
  • [32] Experimental validation of computational fluid dynamics for solving isothermal and incompressible viscous fluid flow
    Bilen Emek Abali
    Ömer Savaş
    SN Applied Sciences, 2020, 2
  • [33] Experimental validation of computational fluid dynamics for solving isothermal and incompressible viscous fluid flow
    Abali, Bilen Emek
    Savas, Omer
    SN APPLIED SCIENCES, 2020, 2 (09):
  • [34] COMPUTATIONAL FLUID DYNAMICS BASED INVESTIGATION OF THE PERFORMANCE OF HYBRID HEAT SINKS
    Alkhazaleh, Anas
    Selim, Mohamed Younes El-Saghir
    Alnaimat, Fadi
    Mathew, Bobby
    PROCEEDINGS OF THE ASME 2021 HEAT TRANSFER SUMMER CONFERENCE (HT2021), 2021,
  • [35] A theoretical model and experimental investigation of fluid flow in granite rough fracture
    Dong, Yunsheng
    Xi, Baoping
    He, Shuixin
    Chen, Luhai
    Liu, Keliu
    Gao, Pengli
    PHYSICS OF FLUIDS, 2025, 37 (01)
  • [36] Experimental Investigation of Heat Pipe Flow Dynamics and Performance
    Yilgor, Ilyas
    Shi, Shanbin
    NUCLEAR SCIENCE AND ENGINEERING, 2024,
  • [37] Performance optimization of ultrasonic flow meter based on computational fluid dynamics
    Peng, Shanbi
    Liao, Wen
    Tan, Huan
    ADVANCES IN MECHANICAL ENGINEERING, 2018, 10 (08):
  • [38] Computational fluid dynamics analysis of the effect of throat diameter on the fluid flow and performance of ejector
    Salehi, Mohammadreza
    Pourmahmoud, Nader
    Hassanzadeh, Amir
    Hoseinzadeh, S.
    Heyns, P. S.
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2021, 31 (03) : 733 - 752
  • [39] The impact of flow distribution on column performance: A computational fluid dynamics study
    Smits, Wim
    Deridder, Sander
    Desmet, Gert
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1369 : 125 - 130
  • [40] Computational fluid dynamics investigation on frictional heat transfer flow process by using fluid method
    Kumar, R. Ramesh
    Babu, J. M.
    Varatharajan, R.
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2019, 43 (01) : 883 - 893