Evaluation of the Succeeder SF-8200 Fully Automated Coagulation Analyzer

被引:2
|
作者
Zengi, Oguzhan [1 ,2 ]
Kucuk, Suat H.
机构
[1] Hlth Sci Univ, Bagcilar Training, Dept Med Biochem, Istanbul, Turkey
[2] Res Hosp, Istanbul, Turkey
关键词
analyzer comparison; Bland-Altman plot; SF-8200; coagulometer; Passing-Bablok regression;
D O I
10.7754/Clin.Lab.2021.210151
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The SF-8200 is a new coagulation analyzer developed by Beijing Succeeder Technology Inc., China. The SF-8200 is able to perform clotting, chromogenic, and immunoturbidimetric tests. System capability is a throughput of up to 360 tests per hour, 60 sample tubes can be loaded at any time, and its reaction cuvette capacity is 1,000. The analyzer also has an optional cap piercing module to reduce manual sampling time. We aimed to perform an analytical performance comparison study between Succeeder SF-8200 and Stago Compact Max3 because fully automated coagulation analyzers have become one of the most essential components of clinical laboratories. Methods: Routine coagulation tests were assessed, which are the most ordered in laboratories such as PT, aPTT, and fibrinogen. Stago Compact Max-3 was accepted as the reference instrument in the comparison study. The assay precisions were assessed using fresh and pooled plasma samples or consumer internal quality controls. Hemolysis, lipemia, and icterus interferences were also verified. Results: The coefficients of variation assessed in the intra and inter-assay precision analyses were below 5% representatively for assessed parameters. The inter-analyser comparison demonstrated good results. Results obtained by the SF-8200 showed high comparability predominantly to used reference analyzers, with correlation coefficients ranging from 0.953 to 0.976. In our routine laboratory setting, SF-8200 reached a sample throughput rate of 360 tests per hour. No considerable influence on tests was found for elevated levels of free hemoglobin, bilirubin, or triglycerides. Conclusions: In conclusion, the SF-8200 was an accurate, precise, and reliable coagulation analyzer in routine testing. According to our study, the results demonstrated excellent technical and analytical performance.
引用
收藏
页码:2316 / 2322
页数:7
相关论文
共 50 条
  • [1] EVALUATION OF AN AUTOMATED COAGULATION ANALYZER
    JOHNSTON, M
    ANDREW, M
    THROMBOSIS AND HAEMOSTASIS, 1987, 58 (01) : 127 - 127
  • [2] Evaluation of Sysmex Fully Automated CS Series Coagulation Analyzer at a Tertiary Care Hospital
    Gupta, Monali
    Melinkeri, Sameer Ramesh
    Prabhakaran, Anusree
    Choksey, Urmi
    BLOOD, 2017, 130
  • [3] EVALUATION OF A NEW UNIQUE AUTOMATED COAGULATION ANALYZER
    JOHNSTON, M
    ANDREW, M
    BLOOD, 1993, 82 (10) : A594 - A594
  • [4] Evaluation and performance characteristics of the Q Hemostasis Analyzer, an automated coagulation analyzer
    Toulon, Pierre
    Fischer, Florence
    Appert-Flory, Anny
    Jambou, Didier
    THROMBOSIS RESEARCH, 2014, 133 (05) : 927 - 935
  • [5] Incompatibility of a recombinant thromboplastin and an APTT reagent on a fully automated coagulation analyzer
    Kappelmayer, J
    Ajzner, E
    Muszbek, L
    BLOOD COAGULATION & FIBRINOLYSIS, 1997, 8 (04) : 251 - 252
  • [6] Evaluation of the automated coagulation analyzer SYSMEX CA 6000
    Quehenberger, P
    Kapiotis, S
    Handler, S
    Ruzicka, K
    Speiser, W
    THROMBOSIS RESEARCH, 1999, 96 (01) : 65 - 71
  • [7] EVALUATION OF A NEW FULLY AUTOMATED GLYCOSYLATED HEMOGLOBIN ANALYZER
    SIVORINOVSKY, G
    KEENAN, D
    BARTLING, D
    TANAKA, S
    DIABETES, 1986, 35 : A116 - A116
  • [9] Evaluation of the automated coagulation analyzer Sysmex® CA-7000
    Dorn-Beineke, A
    Dempfle, CE
    Bertsch, T
    Wisser, H
    THROMBOSIS RESEARCH, 2005, 116 (02) : 171 - 179
  • [10] Evaluation and performance characteristics of the automated coagulation analyzer Coapresta 2000
    Hamada, E.
    Fujiwara, A.
    Takumi, H.
    Maekawa, M.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A28 - A28