Sample entropy of laser Doppler flowmetry signals increases in patients with systemic sclerosis

被引:12
|
作者
Figueiras, E. [1 ]
Roustit, M. [2 ]
Semedo, S. [1 ]
Requicha Ferreira, L. F. [1 ]
Crascowski, J. L. [2 ]
Humeau, A. [3 ]
机构
[1] Univ Coimbra, Fac Sci & Technol, Dept Phys, Instrumentat Ctr GEI CI, P-3004516 Coimbra, Portugal
[2] CHU Grenoble, Ctr Invest Clin Grenoble, INSERM CIC3, Unite Pharmacol Clin, F-38043 Grenoble 09, France
[3] Univ Angers, LISA, F-49000 Angers, France
关键词
HEART-RATE-VARIABILITY; TIME-SERIES ANALYSIS; SKIN BLOOD-FLOW; APPROXIMATE ENTROPY; SPECTRAL-ANALYSIS; PERFUSION SIGNAL; TEMPERATURE; DISEASE; HUMANS; COMPLEXITY;
D O I
10.1016/j.mvr.2011.05.007
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Associated to reactivity tests, laser Doppler flowmetry (LDF) emphasizes abnormal skin microvascular function in diseases affecting digits, such as Raynaud's phenomenon (RP) and systemic sclerosis (SSc). However, baseline perfusion value does not discriminate between disease states. We study if LDF sample entropy (SampEn) allows distinguishing healthy subjects, RP and SSc patients. LDF measurements were performed on finger pad and forearm of 108 subjects (27 controls, 28 RP patients, 53 SSc patients), before and after local thermal hyperemia. We also assessed the reproducibility of SampEn [expressed as within-subject coefficients of variation (CV) and intra-class correlation coefficients (ICC)]. Baseline SampEn is significantly increased in patients with SSc compared to RP and controls on finger pad [0.49 (0.19), 0.38 (0.14) and 0.36 (0.15), respectively: P<0.002], but not on forearm. However, local thermal hyperemia increased SampEn at all sites and for all groups. Finally, reproducibility of SampEn computed on two baseline segments was acceptable (CV=26%, ICC=0.63). SampEn of skin blood flow at rest is increased on finger pad of patients with SSc but not on forearm. This is consistent with the pathophysiology of the disease, which predominantly affects digital microcirculation in most patients. SampEn of LDF signal could be a reproducible tool to predict digital microvascular impairment. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:152 / 155
页数:4
相关论文
共 50 条
  • [21] Empirical Mode Decomposition applied to laser Doppler flowmetry signals: Diagnosis approach
    Assous, Sayd
    Humeau, Anne
    L'Huillier, Jean-Pierre
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1232 - 1235
  • [22] COCHLEAR BLOOD-FLOW INCREASES AFTER SYSTEMIC HEMODILUTION - COMPARISON OF SIMULTANEOUS LASER DOPPLER FLOWMETRY AND RADIOACTIVE MICROSPHERE MEASUREMENTS
    NUTTALL, AL
    HULTCRANTZ, E
    LARSEN, HC
    ANGELBORG, C
    HEARING RESEARCH, 1988, 34 (03) : 215 - 223
  • [23] Changes in laser Doppler flowmetry induced by sumatriptan in migraine patients
    De Marinis, M
    Randi, F
    Mingoia, M
    Accornero, N
    CEPHALALGIA, 2005, 25 (08) : 664 - 665
  • [25] Multiscale Compression Entropy of Microvascular Blood Flow Signals: Comparison of Results from Laser Speckle Contrast and Laser Doppler Flowmetry Data in Healthy Subjects
    Humeau-Heurtier, Anne
    Baumert, Mathias
    Mahe, Guillaume
    Abraham, Pierre
    ENTROPY, 2014, 16 (11) : 5777 - 5795
  • [26] Laser Doppler imaging evaluation of nitroglycerin patch application in systemic sclerosis patients
    Bentea, Georgiana Pintea
    Wauters, Aurelien
    Wautrecht, Jean-Claude
    Cogan, Elie
    VASCULAR MEDICINE, 2020, 25 (06) : 559 - 568
  • [27] Lyapunov exponents of laser Doppler flowmetry signals in healthy and type 1 diabetic subjects
    Humeau, A
    Stefanovska, A
    Abraham, P
    ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (11) : 1574 - 1581
  • [28] Lyapunov Exponents of Laser Doppler Flowmetry Signals in Healthy and Type 1 Diabetic Subjects
    Anne Humeau
    Aneta Stefanovska
    Pierre Abraham
    Annals of Biomedical Engineering, 2005, 33 : 1574 - 1581
  • [29] STUDY OF DIGITAL BLOOD PRESSURE AND LASER DOPPLER FLOWMETRY SIGNALS THROUGH A MULTISCALE ANALYSIS
    Guerreschi, Emmanuelle
    Humeau-Heurtier, Anne
    Bricq, Stephanie
    Mahe, Guillaume
    Leftheriotis, Georges
    2012 PROCEEDINGS OF THE 20TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO), 2012, : 1796 - 1800
  • [30] NON-PULPAL SIGNALS AND LASER-DOPPLER FLOWMETRY OF THE DENTAL-PULP
    EVANS, D
    STRANG, R
    REID, J
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 861 - 861