Data filtering in the readout of the CMS Electromagnetic Calorimeter

被引:0
|
作者
Almeida, N. [1 ]
Silva, P. [1 ]
Da Silva, J. C. [1 ]
Husejko, M. [1 ]
Jain, A. [1 ]
Musella, P. [1 ]
Mendes, A. [1 ]
Gallinaro, M. [1 ]
Varela, J. [1 ]
Faure, J. -L. [2 ]
Gras, P. [2 ]
Mandjavidze, L. [2 ]
Busson, P. [3 ]
Paganini, P. [3 ]
机构
[1] LIP, Lisbon, Portugal
[2] CEA Saclay, DAPNIA, Saclay, France
[3] Ecole Polytech, CNRS, IN2P3, LLR, F-91128 Palaiseau, France
关键词
data acquisition; data filtering; CMS; LHC; trigger system; selective readout; trigger systems;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For an efficient data talking, the Electromagnetic Calorimeter (ECAL) data of the CMS experiment must be limited to 10% of the full event size (INS). Other requirements limit the average data size to 2kB per data acquisition link. These conditions imply a reduction factor of close to twenty on the data collected. The data filtering in the readout of the ECAL detector is discussed. Test beam data are used to study the digital filtering applied in the readout channels and a full detector simulation allows to estimate the energy thresholds to achieve the desired data suppression factor.
引用
收藏
页码:571 / +
页数:2
相关论文
共 50 条
  • [41] The Electromagnetic Calorimeter of the CMS experiment
    Diemoz, M
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 956 - 960
  • [42] The electromagnetic calorimeter of the CMS experiment
    Diemoz, Marcella
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 581 (1-2): : 380 - 383
  • [43] Calibration of the CMS electromagnetic calorimeter
    Paramatti, R
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 107 - 111
  • [44] On-beam system test of the new readout electronics for the CMS Electromagnetic Calorimeter upgrade
    Campana, Mattia
    JOURNAL OF INSTRUMENTATION, 2024, 19 (02)
  • [45] Overview of the CMS electromagnetic calorimeter
    Heath, HF
    ADVANCED TECHNOLOGY AND PARTICLE PHYSICS, PROCEEDINGS, 2002, 1 : 384 - 388
  • [46] The Electromagnetic Calorimeter of the CMS experiment
    Diemoz, M
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 100 - 106
  • [47] CMS Electromagnetic Calorimeter preparation towards the LHC data taking
    Meridiani, Paolo
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2008, 177 : 316 - 317
  • [48] Low voltage supply system for the very front end readout electronics of the CMS electromagnetic calorimeter
    Betev, B
    Denes, P
    Djambazov, L
    Dröge, M
    Faure, JL
    Iliev, B
    Lustermann, W
    Nanov, I
    Raykov, P
    Shivarov, N
    PROCEEDINGS OF THE FIFTH WORKSHOP ON ELECTRONICS FOR LHC EXPERIMENTS, 1999, : 397 - 401
  • [49] The CMS electromagnetic calorimeter upgrade: high-rate readout with precise time and energy resolution
    Mijuskovic, Jelena
    JOURNAL OF INSTRUMENTATION, 2022, 17 (01):
  • [50] Avalanche photodiodes for the CMS electromagnetic calorimeter
    Longo, E
    PROCEEDINGS OF THE SEVENTH INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS, 1998, : 406 - 412