Dose reduction in paediatric cranial CT via iterative reconstruction: a clinical study in 78 patients

被引:8
|
作者
Kaul, D. [1 ,2 ,3 ,4 ]
Kahn, J. [1 ,2 ]
Huizing, L. [1 ,2 ]
Wiener, E. [1 ,2 ]
Boening, G. [1 ,2 ]
Renz, D. M. [5 ]
Streitparth, F. [1 ,2 ]
机构
[1] Charite Sch Med, Dept Radiol, Charitepl 1, D-10117 Berlin, Germany
[2] Univ Hosp, Charitepl 1, D-10117 Berlin, Germany
[3] Charite Sch Med, Dept Radiat Oncol, Augustenburger Pl 1, D-13353 Berlin, Germany
[4] Univ Hosp, Augustenburger Pl 1, D-13353 Berlin, Germany
[5] Jena Univ Hosp, Dept Radiol, Erlanger Allee 101, D-07747 Jena, Germany
关键词
FILTERED BACK-PROJECTION; IMAGE QUALITY; HEAD CT; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; CANCER; RISK;
D O I
10.1016/j.crad.2016.06.115
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To assess how adaptive statistical iterative reconstruction (ASIR) contributes to dose reduction and affects image quality of non-contrast cranial computed tomography (cCT) in children. MATERIALS AND METHODS: Non-contrast cranial CT acquired in 78 paediatric patients (age 0-12 years) were evaluated. The images were acquired and processed using four different protocols: Group A (control): 120 kV, filtered back projection (FBP), n=18; Group B: 100 kV, FBP, n=22; Group C: 100 kV, scan and reconstruction performed with 20% ASIR, n=20; Group D1: 100 kV, scan and reconstruction performed with 30% ASIR, n=18; Group D2: raw data from Group D1 reconstructed using a blending of 40% ASIR and 60% FBP, n=18. The effective dose was calculated and the image quality was assessed quantitatively and qualitatively. RESULTS: Compared to Group A, Groups C and D1/D2 showed a significant reduction of the dose-length product (DLP) by 34.4% and 64.4%, respectively. All experimental groups also showed significantly reduced qualitative levels of noise, contrast, and overall diagnosability. Diagnosis-related confidence grading showed Group C to be adequate for everyday clinical practice. Quantitative measures of Groups B and C were comparable to Group A with only few parameters compromised. Quantitative scores in Groups D1 and D2 were mainly lower compared to Group A, with Group D2 performing better than Group Dl. Group D2 was considered adequate for follow-up imaging of severe acute events such as bleeding or hydrocephalus. DISCUSSION: The use of ASIR combined with low tube voltage may reduce radiation significantly while maintaining adequate image quality in non-contrast paediatric cCT. (C) 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1168 / 1177
页数:10
相关论文
共 50 条
  • [1] Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT
    Gay, F.
    Pavia, Y.
    Pierrat, N.
    Lasalle, S.
    Neuenschwander, S.
    Brisse, H. J.
    EUROPEAN RADIOLOGY, 2014, 24 (01) : 102 - 111
  • [2] Dose reduction with adaptive statistical iterative reconstruction for paediatric CT: phantom study and clinical experience on chest and abdomen CT
    F. Gay
    Y. Pavia
    N. Pierrat
    S. Lasalle
    S. Neuenschwander
    H. J. Brisse
    European Radiology, 2014, 24 : 102 - 111
  • [3] Radiation dose reduction in paediatric cranial CT
    Chan, CY
    Wong, YC
    Chau, LF
    Yu, SK
    Lau, PC
    PEDIATRIC RADIOLOGY, 1999, 29 (10) : 770 - 775
  • [4] Radiation dose reduction in paediatric cranial CT
    C.-Y. Chan
    Yiu-chung Wong
    Luen-fai Chau
    S.-K. Yu
    Po-chung Lau
    Pediatric Radiology, 1999, 29 : 770 - 775
  • [5] CT dose reduction using Automatic Exposure Control and iterative reconstruction: A chest paediatric phantoms study
    Greffier, Jol
    Pereira, Fabricio
    Macri, Francesco
    Beregi, Jean-Paul
    Larbi, Ahmed
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (04): : 582 - 589
  • [6] Dose reduction with iterative reconstruction: Optimization of CT protocols in clinical practice
    Greffier, J.
    Macri, F.
    Larbi, A.
    Fernandez, A.
    Khasanova, E.
    Pereira, F.
    Mekkaoui, C.
    Beregi, J. P.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2015, 96 (05) : 477 - 486
  • [7] Cranial CT with Adaptive Statistical Iterative Reconstruction: Improved Image Quality with Concomitant Radiation Dose Reduction
    Rapalino, O.
    Kamalian, Shervin
    Kamalian, Shahmir
    Payabvash, S.
    Souza, L. C. S.
    Zhang, D.
    Mukta, J.
    Sahani, D. V.
    Lev, M. H.
    Pomerantz, S. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (04) : 609 - 615
  • [8] CT pulmonary angiography: dose reduction via a next generation iterative reconstruction algorithm
    Sauter, Andreas
    Koehler, Thomas
    Brendel, Bernhard
    Aichele, Juliane
    Neumann, Jan
    Noel, Peter B.
    Rummeny, Ernst J.
    Muenzel, Daniela
    ACTA RADIOLOGICA, 2019, 60 (04) : 478 - 487
  • [9] Clinical Experience with Radiation Dose Reduction of CT Examinations Using Iterative Reconstruction Algorithms
    Weir, V.
    Zhang, J.
    MEDICAL PHYSICS, 2016, 43 (06) : 3368 - 3368
  • [10] Radiation Dose Reduction with Hybrid Iterative Reconstruction for Pediatric CT
    Singh, Sarabjeet
    Kalra, Mannudeep K.
    Shenoy-Bhangle, Anuradha S.
    Saini, Aashna
    Gervais, Debra A.
    Westra, Sjirk J.
    Thrall, James H.
    RADIOLOGY, 2012, 263 (02) : 537 - 546