Current disparity in multi-column surge arresters

被引:9
|
作者
Haddad, A [1 ]
Waters, RT [1 ]
German, DM [1 ]
Abdul-Malek, Z [1 ]
机构
[1] Cardiff Univ, High Voltage Grp, Cardiff CF24 3AA, Wales
关键词
D O I
10.1049/ip-gtd:20045051
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
High-voltage surge arresters for high-current, high-energy duty often comprise several parallel ZnO columns. The extreme nonlinearity of the voltage-current characteristics of these columns demands close matching. However, even initially well matched columns can be unbalanced by ageing, partial discharges, self inductance and thermal effects. Two test techniques are described to examine current disparity in a pair of parallel 15 kV rated surge arresters: these are a current-ratio method and a current-difference method. The tests allow three aspects of parallel operation to be investigated: the use of ballast resistors to minimise mismatch effects and to increase energy absorption rating; the influence of the arrester layout on current parity; and temperature-difference perturbation of transient characteristics.
引用
收藏
页码:945 / 951
页数:7
相关论文
共 50 条
  • [21] The algorithms for calculating the leakage current resistive component in surge arresters
    Olesz, Marek
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (11A):
  • [22] Study on the resistive leakage current characteristic of MOV surge arresters
    Yan, XL
    Wen, YF
    Yi, XY
    IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXHIBITION 2002: ASIA PACIFIC, VOLS 1-3, CONFERENCE PROCEEDINGS: NEW WAVE OF T&D TECHNOLOGY FROM ASIA PACIFIC, 2002, : 683 - 687
  • [23] Validating multi-column schema matchings by type
    Dai, Bing Tian
    Koudas, Nick
    Srivastava, Divesh
    Tung, Anthony K. H.
    Venkatasubramanian, Suresh
    2008 IEEE 24TH INTERNATIONAL CONFERENCE ON DATA ENGINEERING, VOLS 1-3, 2008, : 120 - +
  • [24] Analysis of Cordycepsby multi-column liquid chromatography
    Qian, Zhengming
    Li, Shaoping
    ACTA PHARMACEUTICA SINICA B, 2017, 7 (02) : 202 - 207
  • [25] EXPERIMENTAL EVALUATION OF RESISTIVE LEAKAGE CURRENT IN GIS SURGE ARRESTERS
    Rao, Mandava M.
    Kumar, Mritunjay
    INTERNATIONAL JOURNAL OF POWER AND ENERGY SYSTEMS, 2016, 36 (01): : 1 - 8
  • [26] CURRENT-LIMITING DISCONNECTOR FOR DISTRIBUTION SURGE ARRESTERS.
    Lat, M.V.
    Kortschinski, J.
    Research Review - Ontario Hydro, 1980, (01): : 31 - 34
  • [27] Testing of Surge Arresters
    Dzmura, Jaroslav
    Balogh, Jozef
    Petras, Jaroslav
    Dolnik, Bystrik
    PROCEEDINGS OF THE 13TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2012, VOLS 1 AND 2, 2012, : 899 - 902
  • [28] INTELLIGENT OPTIMIZATION OF MULTI-COLUMN SYSTEM OF CHROMATOGRAPHY
    LU, PC
    ZHANG, XM
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8): : 633 - 638
  • [29] Implementation of multi-column chromatography for affinity purificaiton
    Snyder, Chase
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 255
  • [30] Automatic Float Placement in Multi-Column Documents
    Marriott, Kim
    Moulder, Peter
    Hurst, Nathan
    DOCENG'07: PROCEEDINGS OF THE 2007 ACM SYMPOSIUM ON DOCUMENT ENGINEERING, 2007, : 125 - 134