Administration and clearance of amphotericin B during high-efficiency or high-efficiency/high-flux dialysis

被引:1
|
作者
Gussak, HM [1 ]
Rahman, S [1 ]
Bastani, B [1 ]
机构
[1] St Louis Univ, Sch Med, Div Nephrol, St Louis, MO 63110 USA
关键词
amphotericin; clearance; hemodialysis;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Administration and clearance of amphotericin B infused during high-efficiency or high-efficiency/high-flux dialysis were studied In two end-stags renal disease patients requiring systemic antimycotic treatment for fungal peritonitis, Amphotericin B concentrations were measured in the arterial and venous dialysis ports as well as in the ultrafiltrate. Amphotericin B is poorly dialyzable while administered during hemodialysis sessions with high-efficiency (CA 210) or high-efficiency/high-flux (CT 190 G) membranes. Amphotericin B Infusion during hemodialysis was well tolerated and can be administered conveniently In an outpatient dialysis setting, avoiding prolonged hospitalization for parenteral antifungal therapy. (C) 2001 by the National Kidney Foundation, Inc.
引用
收藏
页码:art. no. / e45
页数:3
相关论文
共 50 条
  • [41] High-efficiency parallelism solution for a Multiview High-Efficiency Video Coding decoder
    Liu, Wei
    Li, Wei
    Cho, Yong Beom
    JOURNAL OF PARALLEL AND DISTRIBUTED COMPUTING, 2020, 141 : 115 - 128
  • [42] High-efficiency light valve projectors and high-efficiency laser light sources
    Glenn, WE
    Holton, CE
    Dixon, GJ
    Bos, PJ
    SMPTE JOURNAL, 1997, 106 (04): : 210 - 216
  • [43] HETEROGENEITY IN GENTAMICIN CLEARANCE BETWEEN HIGH-EFFICIENCY HEMODIALYZERS
    AGARWAL, R
    CRONIN, RE
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 23 (01) : 47 - 51
  • [44] REDUCTION IN COMPLICATIONS AND ULTRAFILTRATION INTOLERANCE IN HIGH-EFFICIENCY DIALYSIS
    GRAEFE, U
    FOLLETTE, WC
    SCRIBNER, BH
    KIDNEY INTERNATIONAL, 1977, 12 (01) : 81 - 81
  • [45] Comparison of urea clearance in low-efficiency low-flux vs. high-efficiency high-flux dialyzer membrane with reduced blood and dialysate flow: An in vitro analysis
    Munshi, Raj
    Ahmad, Suhail
    HEMODIALYSIS INTERNATIONAL, 2014, 18 (01) : 172 - 174
  • [46] High haematocrit does not adversely affect the efficiency of high-flux dialysis therapies
    Spalding, E.
    Pandya, P.
    Farrington, K.
    SCOTTISH MEDICAL JOURNAL, 2007, 52 (02) : 49 - 49
  • [47] CLEARANCE OF VANCOMYCIN BY HIGH-FLUX DIALYSIS MEMBRANES
    REETZE, P
    BOEHLER, J
    KELLER, E
    KRAMER, A
    SCHOLLMEYER, PJ
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1990, 19 (11) : 504 - 505
  • [48] Vancomycin clearance with high-flux dialysis membranes
    Anandan, JV
    Touchette, MA
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1998, 21 (03): : 131 - 133
  • [49] High-efficiency LED torch
    Crichton, J
    ELECTRONICS WORLD, 2005, 111 (1831): : 53 - 53
  • [50] High-efficiency infrared receiver
    Esman, A. K.
    Kostenko, V. I.
    Mukhurov, N. I.
    Zykov, G. L.
    Potachits, V. A.
    DEVICES AND METHODS OF MEASUREMENTS, 2016, 7 (02): : 129 - 135