The effect of intermittent operation on a wind-powered membrane system for brackish water desalination

被引:19
|
作者
Park, G. L. [1 ]
Schaefer, A. I. [2 ]
Richards, B. S. [1 ]
机构
[1] Heriot Watt Univ, Sch Engn & Phys Sci, Edinburgh EH14 4AS, Midlothian, Scotland
[2] Univ Edinburgh, Sch Engn, Edinburgh EH9 3JL, Midlothian, Scotland
关键词
desalination; power fluctuation; renewable energy; reverse osmosis; wind energy; REVERSE-OSMOSIS SYSTEM; SEAWATER DESALINATION; PLANT; UNIT; DESIGN; ENERGY; PERFORMANCE; COMMUNITIES; TECHNOLOGY; EXPERIENCE;
D O I
10.2166/wst.2012.912
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Renewable energy powered membrane systems that are directly-connected must take account of both the inherent fluctuations and the intermittency of the energy resource. In order to determine the effect of intermittent operation, a membrane system was tested with variables of (i) amplitude from 60 to 300 Wand (ii) length of time with no power from 0.5 to 3 min. This was performed over one hour periods with six on/off cycles to simulate the system operating under intermittent operation for short periods of time when directly-connected to a small wind turbine. The setup used a Filmtec BW30-4040 brackish water reverse osmosis membrane with feed waters of 2,750 mg/L and 5,500 mg/L NaCl. The results showed that the membrane system produced potable water under the majority of intermittency experiments performed. There was a relatively large increase in the average salt concentration of the permeate, especially when the system was off for shorter periods of time (0.5-1 min). Longer periods of no power (1-3 min) did not have as significant an effect on the average water quality. This is important when the need for energy buffering or short term storage is considered for these systems as it shows the potential for improving the overall flux and water quality using temporary energy storage.
引用
收藏
页码:867 / 874
页数:8
相关论文
共 50 条
  • [31] Economic viability of a wind-powered hydroelectric system
    Cheng, E
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1998, 74-6 : 411 - 418
  • [32] An economic evaluation of renewable energy-powered membrane distillation for desalination of brackish water
    Usman, Haamid Sani
    Touati, Khaled
    Rahaman, Md Saifur
    RENEWABLE ENERGY, 2021, 169 : 1294 - 1304
  • [33] Methodology for life cycle assessment of brackish water desalination unit powered by hybrid photovoltaic-wind power system
    Cherif, Habib
    Belhadj, Jamel
    Champenois, Gerard
    2014 INTERNATIONAL CONFERENCE ON GREEN ENERGY, 2014, : 38 - 43
  • [34] Dynamic simulation of wind-powered alkaline water electrolysis system for hydrogen production
    Wang, Yue
    Ren, Shenlong
    Che, Xunjian
    Yu, Shipeng
    Chen, Jie
    Li, Qian
    Cai, Weihua
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 97 : 391 - 405
  • [35] Wind-powered electric water-pumping system installed in a remote location
    Al Suleimani, Z
    Rao, NR
    APPLIED ENERGY, 2000, 65 (1-4) : 339 - 347
  • [36] Optimal Control of a Reverse Osmosis Plant for Brackish Water Desalination Driven by Intermittent Wind Power
    Ali, Emad
    MEMBRANES, 2022, 12 (04)
  • [37] Effect of intermittent operation modes on performance of reverse osmosis (RO) membrane in desalination and water treatment
    Yang, Heungsik
    Choi, Jihyeok
    Choi, Yongjun
    Lee, Sangho
    MEMBRANE AND WATER TREATMENT, 2022, 13 (01): : 39 - 49
  • [38] Preliminary experimental study of a small reverse osmosis wind-powered desalination plant
    Moreno, F
    Pinilla, A
    DESALINATION, 2005, 171 (03) : 257 - 265
  • [39] Potential of wind-powered renewable energy membrane systems for Ghana
    Park, G. L.
    Schaefer, A. I.
    Richards, B. S.
    DESALINATION, 2009, 248 (1-3) : 169 - 176
  • [40] The SDAWES project:: an ambitious R&D prototype for wind-powered desalination
    Carta, JA
    González, J
    Subiela, V
    DESALINATION, 2004, 161 (01) : 33 - 48