Analysis of a power topology for a quasi-resonant fast on-load tap changing regulator

被引:0
|
作者
Echavarría, R [1 ]
Sánchez, V [1 ]
Ponce, M [1 ]
Cotorogea, M [1 ]
Claudio, A [1 ]
机构
[1] Ctr Nacl Invest & Desarrollo Tecnol, CENIDET, Cuernavaca 62050, Morelos, Mexico
关键词
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
The main function of the on-load tap changing (OLTC) regulators consists in maintaining a constant voltage in order to feed critical loads despite the load changes or voltage changes in the ac mains. The traditional regulators are still used nowadays, but present several disadvantages, like a slow response, which reaches from 100 ms to several seconds. These drawbacks can be overcome if the OLTC regulators would have shorter response time, commuting several times every cycle of the mains. There are two basic topologies for fast OLTC regulators, the first one consists of several taps and uses hard switching. The second one consists of two main switches commuting at high frequency, using soft-switching in order to reduce the power losses. The present topology is of the second type. This paper presents a mathematical model of the power stage of the proposed regulator. It includes the parasitic resistances and the leakage inductances in order to obtain a better comprehension of the regulator operation.
引用
收藏
页码:837 / 840
页数:4
相关论文
共 50 条
  • [41] Adaptive on-load tap-changing voltage control for active distribution networks
    Goran Švenda
    Zoran Simendić
    Electrical Engineering, 2022, 104 : 1041 - 1056
  • [42] Analysis of Dynamic Characteristics and its Influence on Electrical Sequence for On-load Tap Changer Fast Mechanism
    Wei F.
    Wang K.
    Li J.
    Yu Y.
    Zhang S.
    Lu Y.
    Li G.
    Zhang J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (14): : 5674 - 5682
  • [43] ANALYSIS AND IMPLEMENTATION OF A QUASI-RESONANT BUCK CONVERTER
    TSAI, MC
    INTERNATIONAL JOURNAL OF ELECTRONICS, 1992, 72 (02) : 223 - 242
  • [44] Power Factor Corrector Based on Parallel Quasi-Resonant Pulse Converter with Fast Current Loop
    Denisov, Yuriy
    Stepenko, Serhii
    ELECTRICAL CONTROL AND COMMUNICATION ENGINEERING, 2013, 3 (01) : 5 - 11
  • [45] Adaptive on-load tap-changing voltage control for active distribution networks
    Svenda, Goran
    Simendic, Zoran
    ELECTRICAL ENGINEERING, 2022, 104 (02) : 1041 - 1056
  • [46] Simplified Power Flow Modeling Approach Considering On-Load Tap Changers
    Alkaabi, Sultan S.
    Zeineldin, H. H.
    Khadkikar, Vinod
    2017 IEEE POWER & ENERGY SOCIETY INNOVATIVE SMART GRID TECHNOLOGIES CONFERENCE (ISGT), 2017,
  • [47] An intellectualized voltage-regulator controlling load tap switch for changing primary winding tap location of power transformer
    Li, W
    Wang, J
    Cai, ZY
    Ma, SH
    Gong, YS
    Lu, CA
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 224 - 226
  • [48] Power Transformer Transient Modeling Considering the Effects of On-Load Tap Changer
    Ahmad, Asad
    Fang, Wanliang
    Liu, Jun
    Hao, Xudong
    2017 4TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT-SWITCHING TECHNOLOGY (ICEPE-ST), 2017, : 766 - 770
  • [49] An assessment method for the reliability of on-load tap-changer of power transformer
    Wang, You-Yuan
    Zhou, Jing-Jing
    Li, Jun
    Du, Lin
    Chen, Wei-Gen
    Chongqing Daxue Xuebao/Journal of Chongqing University, 2010, 33 (07): : 42 - 48
  • [50] Simplified power flow modeling approach considering on-load tap changers
    Alkaabi, Sultan S.
    Zeineldin, H.H.
    Khadkikar, Vinod
    2017 IEEE Power and Energy Society Innovative Smart Grid Technologies Conference, ISGT 2017, 2017,