Air leaks: Stapling affects porcine lungs biomechanics

被引:3
|
作者
Bonnet, Benedicte [1 ]
Tabiai, Ilyass [1 ]
Rakovich, George [2 ]
Gosselin, Frederick P. [1 ]
Villemure, Isabelle [1 ]
机构
[1] Polytech Montreal, Dept Mech Engn, 2500 Chemin Polytech, Montreal, PQ H3T 1J4, Canada
[2] Univ Montreal, Dept Thorac Surg, 2900 Blvd Edouard Montpetit, Montreal, PQ H3T 1J4, Canada
关键词
Lung biomechanics; Pulmonary resection; Air leak; Staple; Digital imaging correlation; GRADUATED-HEIGHT; RANDOMIZED-TRIAL; UPPER LOBECTOMY; COMPLICATIONS; PREDICTORS; RESECTION; MODEL;
D O I
10.1016/j.jmbbm.2021.104883
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
During thoracic operations, surgical staplers resect cancerous tumors and seal the spared lung. However, postoperative air leaks are undesirable clinical consequences: staple legs wound lung tissue. Subsequent to this trauma, air leaks from lung tissue into the pleural space. This affects the lung's physiology and patients' recovery. The objective is to biomechanically and visually characterize porcine lung tissue with and without staples in order to gain knowledge on air leakage following pulmonary resection. Therefore, a syringe pump filled with air inflates and deflates eleven porcine lungs cyclically without exceeding 10 cmH2O of pressure. Cameras capture stereo-images of the deformed lung surface at regular intervals while a microcontroller simultaneously records the alveolar pressure and the volume of air pumped. The raw images are then used to compute tri-dimensional displacements and strains with the Digital Image Correlation method (DIC). Air bubbles originated at staple holes of inner row from exposed porcine lung tissue due to torn pleural on costal surface. Compared during inflation, left upper or lower lobe resections have similar compliance (slope of the pressure vs volume curve), which are 9% lower than healthy lung compliance. However, lower lobes statistically burst at lower pressures than upper lobes (p-value<0.046) in ex vivo conditions confirming previous clinical in vivo studies. In parallel, the lung deformed mostly in the vicinity of staple holes and presented maximum shear strain near the observed leak location. To conclude, a novel technique DIC provided concrete evidence of the post-operative air leaks biomechanics. Further studies could investigate causal relationships between the mechanical parameters and the development of an air leak.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Spinal posture affects whiplash biomechanics
    Stemper, BD
    Yoganandan, N
    Pintar, FA
    2003 ADVANCES IN BIOENGINEERING, 2003, : 377 - 378
  • [22] Management of Air Leaks in the Newborn
    Kastein, Kim
    Coe, Kristi
    ADVANCES IN NEONATAL CARE, 2023, 23 (02) : 160 - 166
  • [23] Persistent Air Leaks Response
    Dugan, Karen C.
    Laxmanan, Balaji
    Murgu, Septimiu
    Hogarth, D. Kyle
    CHEST, 2017, 152 (02) : 450 - 450
  • [24] Management of Persistent Air Leaks
    Dugan, Karen C.
    Laxmanan, Balaji
    Murgu, Septimiu
    Hogarth, D. Kyle
    CHEST, 2017, 152 (02) : 417 - 423
  • [25] AIR LEAKS AND VASOPRESSIN RELEASE
    MCINTOSH, N
    PRAKASH, P
    SMITH, A
    ARCHIVES OF DISEASE IN CHILDHOOD, 1990, 65 (11) : 1259 - 1262
  • [26] DETECTING SYSTEM AIR LEAKS
    SCHAFER, LA
    INSTRUMENTATION TECHNOLOGY, 1970, 17 (07): : 64 - &
  • [27] The effect of vertebral body stapling on spine biomechanics and structure using a bovine model
    Sunni, Nabeel
    Askin, Geoffrey N.
    Labrom, Robert D.
    Izatt, Maree T.
    Pearcy, Mark J.
    Adam, Clayton J.
    CLINICAL BIOMECHANICS, 2020, 74 : 73 - 78
  • [28] ISOLATION OF MYCOPLASMAS FROM PORCINE LUNGS
    PIJOAN, C
    ROBERTS, DH
    MEDICAL LABORATORY TECHNOLOGY, 1973, 30 (02): : 123 - 127
  • [29] Immunohistochemical localization of Haptoglobin in porcine lungs
    Hiss, S.
    Willbrenning, G. Schulze
    Suntz, M.
    Reinacher, M.
    Sauerwein, H.
    ANATOMIA HISTOLOGIA EMBRYOLOGIA, 2008, 37 (03) : 196 - 199
  • [30] GETTING AIR INTO THE LUNGS
    GUILDNER, CW
    EMERGENCY MEDICINE, 1980, 12 (18) : 31 - 33