Development of a Noninvasive Blood Glucose Monitoring System Prototype: Pilot Study

被引:5
|
作者
Valero, Maria [1 ]
Pola, Priyanka [1 ]
Falaiye, Oluwaseyi [2 ]
Ingram, Katherine H. [3 ]
Zhao, Liang [1 ]
Shahriar, Hossain [1 ]
Ahamed, Sheikh Iqbal [4 ]
机构
[1] Kennesaw State Univ, Dept Informat Technol, 680 Arntson Dr,Suite J312, Marietta, GA 30060 USA
[2] Kennesaw State Univ, Dept Software Engn & Game Dev, Marietta, GA 30060 USA
[3] Kennesaw State Univ, Dept Exercise Sci & Sport Management, Kennesaw, GA 30144 USA
[4] Marquette Univ, Dept Comp Sci, Milwaukee, WI 53233 USA
关键词
diabetes; deep learning; machine learning; glucose concentration; noninvasive monitoring; optical sensors; glucose monitoring; SPECTROSCOPY;
D O I
10.2196/38664
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Diabetes mellitus is a severe disease characterized by high blood glucose levels resulting from dysregulation of the hormone insulin. Diabetes is managed through physical activity and dietary modification and requires careful monitoring of blood glucose concentration. Blood glucose concentration is typically monitored throughout the day by analyzing a sample of blood drawn from a finger prick using a commercially available glucometer. However, this process is invasive and painful, and leads to a risk of infection. Therefore, there is an urgent need for noninvasive, inexpensive, novel platforms for continuous blood sugar monitoring. Objective: Our study aimed to describe a pilot test to test the accuracy of a noninvasive glucose monitoring prototype that uses laser technology based on near-infrared spectroscopy. Methods: Our system is based on Raspberry Pi, a portable camera (Raspberry Pi camera), and a visible light laser. The Raspberry Pi camera captures a set of images when a visible light laser passes through skin tissue. The glucose concentration is estimated by an artificial neural network model using the absorption and scattering of light in the skin tissue. This prototype was developed using TensorFlow, Keras, and Python code. A pilot study was run with 8 volunteers that used the prototype on their fingers and ears. Blood glucose values obtained by the prototype were compared with commercially available glucometers to estimate accuracy. Results: When using images from the finger, the accuracy of the prototype is 79%. Taken from the ear, the accuracy is attenuated to 62%. Though the current data set is limited, these results are encouraging. However, three main limitations need to be addressed in future studies of the prototype: (1) increase the size of the database to improve the robustness of the artificial neural network model; (2) analyze the impact of external factors such as skin color, skin thickness, and ambient temperature in the current prototype; and (3) improve the prototype enclosure to make it suitable for easy finger and ear placement. Conclusions: Our pilot study demonstrates that blood glucose concentration can be estimated using a small hardware prototype that uses infrared images of human tissue. Although more studies need to be conducted to overcome limitations, this pilot study shows that an affordable device can be used to avoid the use of blood and multiple finger pricks for blood glucose monitoring in the diabetic population.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] A Noninvasive Blood Pressure Monitoring System
    Balamurugan
    Reddy, S. Ramasubba
    Muthan, S.
    2016 IEEE INTERNATIONAL CONFERENCE ON RECENT TRENDS IN ELECTRONICS, INFORMATION & COMMUNICATION TECHNOLOGY (RTEICT), 2016, : 1999 - 2001
  • [22] QC test for noninvasive glucose monitoring system
    Wu, C
    Kersten, B
    Chen, Q
    Li, J
    Jagasia, P
    ELECTROANALYSIS, 2001, 13 (02) : 117 - 122
  • [23] Noninvasive blood glucose monitoring in the terahertz frequency range
    Cherkasova, Olga
    Nazarov, Maxim
    Shkurinov, Alexander
    OPTICAL AND QUANTUM ELECTRONICS, 2016, 48 (03)
  • [24] Simulating Multisensor Noninvasive Blood Glucose Monitoring Systems
    Asaduzzaman, Abu
    Samadarsinee, Soumyashree
    Chidella, Kishore K.
    SOUTHEASTCON 2016, 2016,
  • [25] Validation of the Noninvasive Blood Glucose Monitoring Device Nirlus
    Meyhoefer, Svenja
    Wilms, Britta
    Ihling, Flavia
    Windjager, Anne
    Herrmann, Vera
    Augustinov, Andrej
    Schmid, Sebastian M.
    DIABETES, 2019, 68
  • [26] Design and Implementation of a Noninvasive Blood Glucose Monitoring Device
    Sarkar, Kamol
    Ahmad, Dhrubo
    Singha, Suvojit Kumar
    Ahmad, Mohiuddin
    2018 21ST INTERNATIONAL CONFERENCE OF COMPUTER AND INFORMATION TECHNOLOGY (ICCIT), 2018,
  • [27] Noninvasive blood glucose monitoring in the terahertz frequency range
    Olga Cherkasova
    Maxim Nazarov
    Alexander Shkurinov
    Optical and Quantum Electronics, 2016, 48
  • [28] Blood glucose and subcutaneous continuous glucose monitoring in critically ill horses: A pilot study
    Vitale, Valentina
    Berg, Lise C.
    Larsen, Bettina Birch
    Hannesdottir, Andrea
    Dybdahl Thomsen, Preben
    Laursen, Sigrid Hyldahl
    Verwilghen, Denis
    van Galen, Gaby
    PLOS ONE, 2021, 16 (02):
  • [29] Noninvasive blood glucose monitoring by newly developed near-infrared spectroscopic system
    Maruo, K
    Tsurugi, M
    Tamura, M
    Ishii, M
    DIABETES, 2002, 51 : A124 - A124
  • [30] Proof of Concept for a New Raman-Based Prototype for Noninvasive Glucose Monitoring
    Pleus, Stefan
    Schauer, Sebastian
    Jendrike, Nina
    Zschornack, Eva
    Link, Manuela
    Hepp, Karl Dietrich
    Haug, Cornelia
    Freckmann, Guido