Cholesteatoma imaging using modified echo-planar diffusion-weighted magnetic resonance imaging

被引:9
|
作者
Flook, E. [1 ]
Izzat, S. [2 ]
Ismail, A. [3 ]
机构
[1] Hope Hosp, ENT Dept, Salford M6 8HD, Lancs, England
[2] Royal Albert Edward Hosp, ENT Dept, Wigan, England
[3] Royal Albert Edward Hosp, Dept Radiol, Wigan, England
来源
JOURNAL OF LARYNGOLOGY AND OTOLOGY | 2011年 / 125卷 / 01期
关键词
Magnetic Resonance Imaging; Diffusion Magnetic Resonance Imaging; Cholesteatoma;
D O I
10.1017/S0022215110001805
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Introduction: Imaging of cholesteatomas can be useful especially in cases of recurrent disease. Computed tomography scans have been recommended before primary surgery, but cholesteatoma tissue looks similar to inflammatory tissue. Diffusion-weighted magnetic resonance imaging is both sensitive and specific in detecting cholesteatoma, which appears as a bright signal on a dark background. Non-echo-planar diffusion-weighted magnetic resonance imaging is superior to routine echo-planar diffusion-weighted magnetic resonance imaging as it minimises susceptibility artefacts; however, the addition of this facility involves expensive magnetic resonance scanner upgrading. Method: To avoid the cost of such upgrading, we modified our echo-planar diffusion-weighted magnetic resonance imaging parameters and then scanned 15 consecutive cases of suspected cholesteatoma or suspected recurrent cholesteatoma. Results: Imaging results correlated well with clinical and/or operative findings. Conclusion: These results indicate that software adjustments can enable echo-planar diffusion-weighted magnetic resonance imaging to detect cholesteatomas reliably, and as effectively as non-echo-planar diffusion-weighted magnetic resonance imaging. This discovery has the potential to facilitate reliable delayed postoperative screening of canal wall up mastoidectomies, avoiding the need for a 'second look' procedure.
引用
收藏
页码:10 / 12
页数:3
相关论文
共 50 条
  • [31] Diffusion-Weighted Imaging with Dual-Echo Echo-Planar Imaging for Better Sensitivity to Acute Stroke
    Holdsworth, S. J.
    Yeom, K. W.
    Antonucci, M. U.
    Andre, J. B.
    Rosenberg, J.
    Aksoy, M.
    Straka, M.
    Fischbein, N. J.
    Bammer, R.
    Moseley, M. E.
    Zaharchuk, G.
    Skare, S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) : 1293 - 1302
  • [32] Postoperative Non-Echo-Planar Diffusion-Weighted Magnetic Resonance Imaging Changes After Cholesteatoma Surgery: Implications for Cholesteatoma Screening
    Dhepnorrarat, Rataphol Chris
    Wood, Bradley
    Rajan, Gunesh P.
    OTOLOGY & NEUROTOLOGY, 2009, 30 (01) : 54 - 58
  • [33] Diagnostic performance of multishot echo-planar imaging (RESOLVE) and non-echo-planar imaging (HASTE) diffusion-weighted imaging in cholesteatoma with an emphasis on signal intensity ratio measurement
    Bozer, Ahmet
    Adibelli, Zehra Hilal
    Yener, Yesim
    Dalgic, Abdullah
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2024, 30 (06): : 370 - 377
  • [34] The role of diffusion-weighted magnetic resonance imaging in the diagnosis of cholesteatoma
    Tosun, Alptekin
    TURKIYE KLINIKLERI TIP BILIMLERI DERGISI, 2008, 28 (03): : 265 - 268
  • [35] A Systematic Review of Non-Echo Planar Diffusion-Weighted Magnetic Resonance Imaging for Detection of Primary and Postoperative Cholesteatoma
    van Egmond, Sylvia L.
    Stegeman, Inge
    Grolman, Wilko
    Aarts, Mark C. J.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 154 (02) : 233 - 240
  • [36] Improve the image quality of orbital 3 T diffusion-weighted magnetic resonance imaging with readout-segmented echo-planar imaging
    Xu, Xiao-Quan
    Liu, Jun
    Hu, Hao
    Su, Guo-Yi
    Zhang, Yu-Dong
    Shi, Hai-Bin
    Wu, Fei-Yun
    CLINICAL IMAGING, 2016, 40 (04) : 793 - 796
  • [37] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [38] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [39] Diffusion-Weighted Echo-Planar Magnetic Resonance Imaging for the Assessment of Tumor Cellularity in Patients With Soft-Tissue Sarcomas
    Schnapauff, Dirk
    Zeile, Martin
    Ben Niederhagen, Manuel
    Fleige, Barbara
    Tunn, Per-Ulf
    Hamm, Bernd
    Dudeck, Oliver
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (06) : 1355 - 1359
  • [40] ACUTE HUMAN STROKE STUDIED BY WHOLE-BRAIN ECHO-PLANAR DIFFUSION-WEIGHTED MAGNETIC-RESONANCE-IMAGING
    WARACH, S
    GAA, J
    SIEWERT, B
    WIELOPOLSKI, P
    EDELMAN, RR
    ANNALS OF NEUROLOGY, 1995, 37 (02) : 231 - 241