Further improvement of hydrostatic pressure sample injection for microchip electrophoresis

被引:8
|
作者
Luo, Yong [1 ]
Zhang, Qingquan [1 ]
Qin, Jianhua [1 ]
Lin, Bingcheng [1 ]
机构
[1] Chinese Acad Sci, Dalian Inst Chem Phys, Dalian 116023, Peoples R China
关键词
hydrostatic pressure sample injection; microchip electrophoresis; microfluidics;
D O I
10.1002/elps.200700330
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydrostatic pressure sample injection method is able to minimize the number of electrodes needed for a microchip electrophoresis process; however, it neither can be applied for electrophoretic DNA sizing, nor can be implemented on the widely used single-cross microchip. This paper presents an injector design that makes the hydrostatic pressure sample injection method suitable for DNA sizing. By introducing an assistant channel into the normal double-cross injector, a rugged DNA sample plug suitable for sizing can be successfully formed within the cross area during the sample loading. This paper also demonstrates that the hydrostatic pressure sample injection can be performed in the single-cross microchip by controlling the radial position of the detection point in the separation channel. Rhodamine 123 and its derivative as model sample were successfully separated.
引用
收藏
页码:4769 / 4771
页数:3
相关论文
共 50 条
  • [1] Negative pressure pinched sample injection for microchip-based electrophoresis
    Zhang, L
    Yin, XF
    Fang, ZL
    LAB ON A CHIP, 2006, 6 (02) : 258 - 264
  • [2] Autonomous polymer loading and sample injection for microchip electrophoresis
    Ito, T
    Inoue, A
    Sato, K
    Hosokawa, K
    Maeda, M
    ANALYTICAL CHEMISTRY, 2005, 77 (15) : 4759 - 4764
  • [3] Improved hydrostatic pressure sample injection by tilting the microchip towards the disposable miniaturized CE device
    Wang, Wei
    Zhou, Fang
    Zhao, Liang
    Zhang, Jian-Rong
    Zhu, Jun-Jie
    ELECTROPHORESIS, 2008, 29 (03) : 561 - 566
  • [4] A shape factor model for injection analysis of microchip sample electrophoresis
    Pezeshkpour, Pegah
    Schneider, Gerry
    Ren, Carolyn
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2020, 77 (01) : 1 - 12
  • [5] Instrumentation design for hydrodynamic sample injection in microchip electrophoresis: A review
    Saito, Renata M.
    Coltro, Wendell K. T.
    de Jesus, Dosil P.
    ELECTROPHORESIS, 2012, 33 (17) : 2614 - 2623
  • [6] Acupuncture Sample Injection for Microchip Capillary Electrophoresis and Electrokinetic Chromatography
    Ha, Ji Won
    Hahn, Jong Hoon
    ANALYTICAL CHEMISTRY, 2016, 88 (09) : 4629 - 4634
  • [7] Bias-free pneumatic sample injection in microchip electrophoresis
    Cho, SI
    Lee, SH
    Chung, DS
    Kim, YK
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1063 (1-2) : 253 - 256
  • [8] Micropumps actuated negative pressure injection for microchip electrophoresis
    Li, Bowei
    Jiang, Lei
    Wang, Qi
    Oin, Jianhua
    Lin, Bingcheng
    ELECTROPHORESIS, 2008, 29 (24) : 4906 - 4913
  • [9] Electrokinetic sample preconcentration and hydrodynamic sample injection for microchip electrophoresis using a pneumatic microvalve
    Cong, Yongzheng
    Katipamula, Shanta
    Geng, Tao
    Prost, Spencer A.
    Tang, Keqi
    Kelly, Ryan T.
    ELECTROPHORESIS, 2016, 37 (03) : 455 - 462
  • [10] MICROCHIP ELECTROPHORESIS WITH SAMPLE STACKING
    JACOBSON, SC
    RAMSEY, JM
    ELECTROPHORESIS, 1995, 16 (04) : 481 - 486